background image

15 

Spraying 

 

Observe the instructions in the section entitled "Safety". 
Operate the device only while it is vertical or suspended upright and nearly vertical. 
Avoid allowing drops of spray to drift onto areas that are not being treated. 
Observe the instructions of the spray product manufacturer! 

1.  Suspend 

the 

device 

from 

your 

shoulder 

or 

place 

it 

on 

your 

back.  

(Fig. 11 and/or 12)

 

To prevent dripping, hold the spray lance up when first spraying and activate the shut-
off valve until no more liquid mixed with air is emerging. 

2.  Activate the shut-off valve [4]. 

(Fig. 13)

 

  Spraying may now begin.  

3.  Make  certain  the  optimum  spraying  pressure  is  set 

(

  Table  2) 

on  the  pressure 

gauge [15]. 

Spraying pressure 

Spraying quantity with nozzle 1302 

1.5 bar  (22 psi) 

0,49 l/min 

2.0 bar (29 psi) 

0,56 l/min 

3.0 bar (43,5 psi) 

0,69 l/min 

Table 2. Linear dependence: spraying rate and spraying pressure 

4.  If  the  spraying  pressure  decreases  more  than  0.5  bar  from  the  optimum  level,  pump 

some more. 

If liquid mixed with air emerges from the nozzle, the tank is empty. 

After usage 

 

Observe the instructions in the section entitled "Safety". 

1.  Pull up the red button on the safety valve [9] until all excess pressure is released from 

the tank. 

(Fig. 4)

 

2.  Remove the cover [10+11]. 

(Chapter entitled "Preparation" Points 2-3, Fig. 5)

 

3.  Dilute the remaining quantity twice in a row  with 1/2 liter of water each time and spray 

the resulting liquid onto the treated area. 

In the case of plant protection products dilute the remaining quantity twice in a row with 

1/2 liter of water each time and spray the resulting liquid onto the treated area.

 

 

Collect  and  dispose  of  the  residual  liquid  according  to  all  applicable  laws, 
requirements  and  regulations.  Observe  the  instructions  of  the  spray  product 
manufacturer! 

4.  Empty and rinse the device with clear water. 
5.  Wipe off the device with a moist cloth. 
6.  For drying and storing the device, keep the tank and pump in a dry place protected from 

sunlight and freezing temperatures.

 (Fig. 14)

 

 

Clean the protective equipment and yourself every time after usage. 

Содержание RESISTENT EXTRA 3592

Страница 1: ...structions for Use 12 F CH B NL CDN Mode d emploi 18 E MEX Instrucciones de uso 24 I CH Istruzioni per l uso 30 S Bruksanvisning 36 FIN K ytt ohje 42 MESTOSpritzenfabrik ErnstStockburgerGmbH Ludwigsbu...

Страница 2: ...ile Spare Parts Pi ces de Rechange Varaosat Reserve onderdelen Varuosade Pezzi di ricambio Reservdelar Reservedele RESISTENT EXTRA 3592 RESISTENT EXTRA PLUS 3592P RESISTENT EXTRA 3602 RESISTENT EXTRA...

Страница 3: ...3 RESISTENT EXTRA 3592 RESISTENT EXTRA PLUS 3592P RESISTENT EXTRA 3602 RESISTENT EXTRA PLUS 3602P 1a 1b 2a 2b 3a 3b 2 5 5 5 3 3 6 4 7 3 5 1 4 6 3 4 7 5 1 6 2 5 3 3 8 6 4 8...

Страница 4: ...4 4 5 6 7 8 9 10 11 12 13 10 12 14 14 11 15 4 13 10 9 11 6 10 11 10 11 10 12 16 2 2 3592 3592P 3602 3602P...

Страница 5: ...5 14 15 16 17 18 19 20 21 22 23 24 17 19 18 24 17 22 20 4 2 21 23 18 20 6 4...

Страница 6: ...n the exterior As of the time of manufacture there are no known harmful effects to the device caused by plant protection products approved by the German Federal Biological Institute the Biologische Bu...

Страница 7: ...ccessory parts We cannot assume any liability resulting from the use of third party parts Wear suitable protective equipment when working with hazardous substances When pumping always observe the pres...

Страница 8: ...excess pressure is released from the tank Fig 4 2 Raise the locking cap 10 tilt the cover 11 screw it in a clockwise direction and take out of the filling opening Fig 5 3 Hook the cover 10 11 onto th...

Страница 9: ...bar from the optimum level pump some more If liquid mixed with air emerges from the nozzle the tank is empty After usage Observe the instructions in the section entitled Safety 1 Pull up the red butto...

Страница 10: ...English Faults Use only MESTO spare and accessory parts Fault Cause Remedy No pressure builds up in the device Cover leaking Close cover properly Fig 7 Grease or replace O ring 16 Fig 15 The pump is n...

Страница 11: ...at the discretion of MESTO replace the device itself or its defective parts If such defects are discovered please contact us immediately We require the invoice or cash register receipt for purchase o...

Отзывы: