SECTION 2: SYSTEM INSTALLATION
NOTICE: Before proceeding with the installa-
tion, we recommend reading through this sec-
tion of the manual for an overall understanding
of the air conditioning fan coil unit and air dis-
tribution system component installation proce-
dures.
STEP 1: LOCATING ThE UNIT
The fan coil unit may be installed in an unconditioned
space (as long as it is protected from the weather) or a
conditioned space such as a basement, closet or utility
room. Please refer to Figure 2.2 for unit sizes and
recommended service clearances.
When selecting a location, consider the location of the
unit in relation to the return air box or filter box as shown
in Figures 2.3, 2.4. The return air duct should have at
least one 90° bend to avoid unnecessary sound feed-
back to the living space from the fan coil unit.
When selecting a location, consider the layout of the
plenum duct, supply tubing, refrigerant lines and conden-
sate drain line.
When installing the unit above a finished ceiling or living
space, install a secondary drain pan. Always follow local
code requirements.
FIGURE 2.2: VERTICAL UNIT DIMENSIONS AND CLEARANCES (Inches)
Model
System
Capacity
(Nom. Tons)
Suction
Line
Liquid
Line
Cond.
Drain
(FPT)
Return
Inlet
(Dia.)
Connections
Recommended
Condensing Unit
Nominal Capacity
(MBH)
Min
SEER
ESP-2430JV
ESP-3642JV
ESP-4860JV
2 – 2-1/2
3 – 3-1/2
4 – 5
Electrical*
Characteristics
230/1/60
230/1/60
230/1/60
7/8"
7/8"
7/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
15"
19"
24"
24 to 30
36 to 42
48 to 60
13+
13+
13+
Model
System
Capacity
(Nom. Tons)
Air Volume
@ 1.5" WC
(SCFM)
Motor
HP
F.L.
Amps
No. of
Rows
Deep
Blower
Holding
Charge
(Dry Nitrogen)
Flow
Control
Type
Ship.
Wt.
(lbs)
ESP-2430JV
ESP-3642JV
ESP-4860JV
2 – 2-1/2
3 – 3-1/2
4 – 5
440, 550
3/4
3/4
3/4
5.6/2
7.6/4
10.6/5.4
6
6
6
7 psi
Exp. Valve
Exp. Valve
Exp. Valve
135
170
210
660, 850
880, 1150
7 psi
7 psi
Coil
Wheel Dia.
and
Width
10" x 6"
10" x 6"
10" x 6"
FIGURE 2.1: MODEL ESP-V SPECIFICATIONS
*Unit includes optional conversion kit to 115V
Содержание SpacePak ESP-2430JV
Страница 11: ...11 FIGURE 2 9 MODEL ESP JV STANDARD WIRING SChEMATIC ...
Страница 12: ...FIGURE 2 10 SINGLE STAGE AIR CONDITIONING ONLY WIRING DIAGRAM 12 ...
Страница 13: ...13 FIGURE 2 11 SINGLE STAGE AIR CONDITIONING WITh hW COIL WIRING DIAGRAM ...
Страница 14: ...14 FIGURE 2 12 TWO STAGE hEAT PUMP AC WIRING DIAGRAM ...
Страница 15: ...15 FIGURE 2 13 TWO STAGE hEAT PUMP AC WITh BACKUP BOILER hEAT WIRING DIAGRAM ...
Страница 33: ...33 NOTES ...
Страница 34: ...NOTES ...
Страница 35: ...35 ...