discharge is avoided.

 3.2  Regulations and References

Protect the batteries from heat (e.g. long times of exposure to  direct sunlight) and fire. Do not immerse the
batteries into fluids. Otherwise there is a risk of explosions.

§

Risk of Damage and Explosion Because of Incorrect Treatment

Unintentional or incorrect treatment can damage the batteries, which can even lead to 
explosions of the batteries!

Batteries  that are integrated  into  the devices of    or are  delivered  with  them,  may  only  be charged  with  the
intended chargers from .

These components are compatible to  each other, other chargers may damage the system or may reduce the
capacity or life span of the batteries significantly.

Respect the following references when operating the chargers:

Use chargers only for charging devices and batteries.

Switch devices off before connecting the charger.

Do NOT switch on the device during the charging process.

Maximum charging current 1 A.

Disconnect charger before turning on the device on.

Prior to the first use, charge the batteries completely.

Charge the batteries before use if you have not used them for a longer period (self discharge of the  NiMH

batteries) and after use.

To avoid capacity loss due to the memory effect, discharge the batteries completely every 5 charging cycles. To

do this, leave the device on, until it turns off by itself. Then start the charging process as described above.

§

Risk Through High Voltage at the Charging Device

The charger works with mains voltage.

Security references for work with mains voltage must be followed.

!

Warning of Reduced Capacity and Life Span of the Batteries due to Maloperation

Use only the intended chargers from .

Powered devices must never be used with a connected charger, e.g. for buffering an empty 
battery.

Disregard can lead to a loss of capacity and a shortened life span of the battery in a short time.

 3.3  Charging the Batteries (Battery Pack or Integrated into the Device)

Start of the Charging Process

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

 

Содержание optoUSB-3.0

Страница 1: ...Manual optoUSB 3 0 Digital optical transmitter for USB signals Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Страница 2: ...eferences 4 3 1 Properties 4 3 2 Regulations and References 5 3 3 Charging the Batteries Battery Pack or Integrated into the Device 6 4 Characteristics and field of application 7 5 Box contents 8 6 Ho...

Страница 3: ...Care and Maintenance Battery packs of the devices have to be maintained on a regular basis see chapter 9 Charging of the battery packs has to be done according to the instructions described in chapte...

Страница 4: ...es Expert only installation of the connections provide a strain relief if necessary Do not mechanically work on devices and cases Do not modify or short circuit plugs and do not shorten or extend incl...

Страница 5: ...ximum charging current 1 A Disconnect charger before turning on the device on Prior to the first use charge the batteries completely Charge the batteries before use if you have not used them for a lon...

Страница 6: ...the device during charging this can damage the device Check the status of the charging LED periodically the meaning of the states are printed onto the housing of the charger End of the Charging Proces...

Страница 7: ...lectronic devices to at no cost 4 2 Disposal of Batteries Due to their natural capacity loss batteries must be replaced after their lifespan NEVER open devices or housings by yourself Replacement of b...

Страница 8: ...prepared for the use of external batteries with the optional battery pack BP84 For the PC side transceiver power is supplied via the USB cable connected to a PC 6 Box contents Quantity Description 2...

Страница 9: ...button with control LED Pwr On Off transceiver HUB side only battery information LED Info transceiver HUB side only charge plug Charge optical connector FSMA Optical I O for duplex multimode fiber 62...

Страница 10: ...a PC Description of transceiver 2 HUB side 2x USB3 0 type A connector to connect USB3 0 devices Control LED Power is on when the transceiver is turned on Control LED Status is on when the two transce...

Страница 11: ...by the operating system The transmission starts automatically after a short initialization If the transmission suddenly stops after a long duration of measurement check the Info LED of the transceive...

Страница 12: ...ies after use with the enclosed charger To prevent a lazy battery effect discharge the devices every 5 times completely by using the automatic switch off Leave the system on until it turns off automat...

Страница 13: ...optoUSB 3 0 Date 20 02 19 Manual Page 13 devices Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Страница 14: ...62 5 125 m Charge batteries Turn on all devices Transmission stops Low battery No optical signal at receiver System turned off Charge batteries Check for light at optical output Replace optical fiber...

Страница 15: ...xm x length in m simplex External batteries BP 84 5f 8 4V 4Ah Connector cable for BP 84 SC 30 5m5m Length approx 30cm Charger with connector plugs CH 1m 5m Standard charger Manual MA optoUSB German o...

Страница 16: ...1x USB 3 0 PC connec on Data rate up to approx 5Gbit s USB3 0 not backward compa ble to USB2 0 1 1 Power supply Hub side 7 NiMH cells with 4 Ah 2 10h depending on power consump on of devices at USB p...

Отзывы: