8.3. Manual Operation of M=LIGHT LED
In the case that the M=Light LED has not yet been parameterized via CAN-bus, manual mode is
activated automatically by application of voltage supply.
Manual Mode Adjustment via CAN-Bus
In the user interface of the M=Light-Control software press Manual and switch the LED off.
Once the M=Light LED is supplied with operating voltage again, it remains switched off until the
ON button is pressed on the rear side of the housing or until another operating mode is
selected via the CAN-bus.
8.3.1. Parameterizing M=Light-LED without CAN-Bus Connection
Disconnect M=Light LED from CAN-bus connection
Supply M=Light LED with operating voltage
Press the ON button on the rear side of the housing (Figure 5, Item 7, page 15).
The M=Light LED is now operating in manual mode. You can adjust the intensity with the help
of the CAN-bus address switch on the rear side of the M=Light LED.
In manual mode, the M=Light LED is always parameterized as described below:
I
Trigger Input
:
Falling edge
I
Pulse Count
: 1
I
Pulse Width
: 300µs
I
Pulse Delay:
0µs
I
Intensity depends on the settings at the address switches (table).
CAN address
Description
MSB
LSB
0
1
Steady light, power 1%*
…
….
*Steady light in 1% increments
6
4
Steady light, power 100%*
0
0
Flash, power 100%
6
5
Flash, power 110%
6
6
Flash, power 120%
6
7
Flash, power 130%
6
8
Flash, power 140%
6
9
Flash, power 150%
6
A
Flash, power 160%
6
B
Flash, power 170%
6
C
Flash, power 180%