8
1. Introduction
Controls
Loosen the four screws securing the panel to ex-
pose the controls and make required adjustments.
Important:
After setup, make sure to lock all four
screws tightly in sequence as indicated in the cau-
tion label after setup to ensure waterproofing.
1.
Diffuser Position Control:
Use the provided
hexagonal wrench to loosen the screw and
move the screw to desired position to adjust
the LED beam angles.
•
0:
No diffuser to occupy over the LED.
•
1~4:
Adjust the position of the diffuser - The higher the number, the greater
the angle of illumination. Actual illumination angle depends on the model.
2.
DIP SW1
•
Pin #1~3:
To sync with the shutter speed of the camera.
Pin #1
Pin #2
Pin #3
Shutter Speed
OFF
OFF
OFF
No allowed.
ON
OFF
OFF
1/250 (Default)
OFF
ON
OFF
1/500
OFF
OFF
ON
1/1K
•
PIN #4:
To turn on/off the RS-485 impedance. If you are chaining multiple
illuminators, set the last one as “ON” and the rest as “OFF”.
3.
DIP SW2
•
Pin #1~7:
To set the ID of the illuminator when chaining multiple illumina-
tors.
ID
Pin #1 Pin #2 Pin #3 Pin #4 Pin #5 Pin #6 Pin #7
000
OFF
OFF
OFF
OFF
OFF
OFF
OFF
001
ON
OFF
OFF
OFF
OFF
OFF
OFF
002
OFF
ON
OFF
OFF
OFF
OFF
OFF
~
~
~
~
~
~
~
~
127
ON
ON
ON
ON
ON
ON
ON
•
Pin #8:
Set #8 to be ON to enforce the telemetry ON/OFF function of the il-
luminator.
2
4
3
1
CAUTION !
Please lock all four screws
tightly in order illustrated
after setup to ensure the
waterproof warranty.
A typical torque of 5-8
kgf-cm is suggested.
1 2 3 4
2
1
4
3
6
5
7 8
Sensitivity
Light
Dark
LED Power
Lo
Hi
ON
ON
0 (OFF)
3 (3/4 ON)
4 (ON)
2 (2/4 ON)
1 (1/4 ON)
Diffuser Position Control
SW1
SW2
Содержание SLI080