Messoa SCB280 Скачать руководство пользователя страница 15

1. Do not touch the imaging surface of sensor. Use soft cloth moistened

with alcohol to clean the surface if it is touched accidentally.

2. Ensure the supply voltage is correct as specified for the particular variant

of camera before operation.

3. Do not expose the camera to rain, moisture or to temperature outside the

specified limit, without a suitable housing.

4. Avoid focusing directly on  the sun.
5. Do not attempt to service this unit yourself unless you are authorised to

*

*

*

do so. Opening the camera may expose you to dangerous voltages or

*

*

*

other hazards. Refer all servicing to qualified personnel only.

*

*

6. If connected to the mains :

*

*

THIS APPARATUS MUST BE EARTHED.

 The wires on the mains lead

*

are in accordance with the following code :

*

GREEN/YELLOW -------------- Earth

*

*

*

*

BLUE -------------------------------Neutral

*

*

BROWN ---------------------------Live

4

*

*

*

*

*

*

7. Warranty void if the S/N label on camera is removed.

5

*

*

*

*

*

*

6

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

1. Camera ------------------------ 1

4. Hexagonal Wrench --------- 1

*

*

*

2. Instruction Manual ---------- 1

5. AI Lens 4-pin Plug ---------- 1

*

*

*

3. Lens Mounting Cap -------- 1

*

*

*

*

*

*

10

*

*

*

*

*

*

*

*

3.1

Basic System Connection :

13

*

*

*

*

*

*

14

*

*

*

*

*

*

15

*

*

*

*

*

*

*

*

*

*

*

*

17

*

*

*

*

*

*

- 2 -

- 15 -

*

18

*

Backlight
Compensation

*

*

*

16

Manual : 1/50, 1/120, 1/250, 1/500, 1/1K, 1/2K, 1/4K, 1/10K
Sec.

Gain Control

Manual : 1/60, 1/100, 1/250, 1/500, 1/1K, 1/2K, 1/4K, 1/10K
Sec.

Shutter Control

Auto : 1/50 to 1/100000 Sec.

STD, WIDE

*

*

*

*

*

OFF / BLC1 / BLC2 / BLC3 / BLC4

*

*

130(L) x 66(W) x 55(H)

500g (max.)

Dimensions

Weights

*

*

Ambient

-10~50

 / 30~90% Relative Humidity

*

*

0.0012 Lux (F1.4,3200

o

K,AGC WIDE,50IRE,B/W Mode)

11

S/N Ratio

Power Source

More than 50dB

DC12V ± 10% Regulated Power Supply
AC24V ± 10% 50Hz / 60Hz ± 1Hz

AC90V  to  AC260V  50Hz / 60Hz

Video Output

Lens Mount

600 TV Lines (Horizontal) Night Mode

Gamma
Correction

0.45 or 1 Selectable

Resolution

CS Mount Only

480 TV Lines (Horizontal) Day Mode

12

Power
Consumption

10W (max) with AI Lens

7

0.03 Lux (F1.4,3200

o

K,AGC WIDE,10IRE,C/L Mode)

0.004 Lux (F1.4,3200

o

K,AGC WIDE,10IRE,B/W Mode)

8

9

Minmum
Illumination

0.003 Lux (F1.4,3200

o

K,AGC WIDE,50IRE,C/L Mode)

Internal / Linelock Selectable (AC Only)

BNC Composite, RJ-45 Cat-O/P, Y/C Output

2 Pickup Elements

768(H)×494(V) Pixels 1/2" Exview Hi-Res CCD

768(H)×494(V) Pixels 1/3" Exview Hi-Res CCD

2:1 Interlace NTSC V:59.94Hz, H:15.734KHz

3

Scanning
System

Sync System

1

ITEM

Image Area

SPECIFICATION

3. SYSTEM CONNECTION

2. SYSTEM COMPONENTS

1. CAUTIONS

11. SPECIFICATIONS

NO

6.5mm×4.9mm

4.9mm×3.7mm

752(H)×582(V) Pixels 1/2" Exview Hi-Res CCD

752(H)×582(V) Pixels 1/3" Exview Hi-Res CCD

2:1 Interlace PAL V:50Hz, H:15.625KHz

*

*

PAL

NTSC

DC12V
AC24V

AC90V

to

AC260V

*

DC12V
AC24V

1/3" 1/2" 1/3" 1/2" 1/3" 1/2"

*

*

*

*

*

*

*

*

*

Содержание SCB280

Страница 1: ...YSTEM COMPONENTS 2 3 SYSTEM CONNECTION 2 4 PIN CONNECTIONS 3 5 PARTS NAMES FUNCTIONS 4 6 PUSH BUTTONS AND THEIR FUNCTIONS 5 7 SETTING MENU 6 8 SUB MENU 7 9 OSD FUNCTION DESCRIPTION 8 10 SYSTEM EXTENSI...

Страница 2: ...attempt to service this unit yourself unless you are authorised to do so Opening the camera may expose you to dangerous voltages or other hazards Refer all servicing to qualified personnel only 6 If...

Страница 3: ...D THE RISK OF ELECTRIC SHOCK DO NOT LET POWER CABLES TOUCH EACH OTHER 4 1 IRIS Connector 4 2 RJ 45 Connector 3 4 PIN CONNECTIONS Function RJ 45 7 8 2 4 5 3 6 1 Pin DATA RS 485 GND POWER 5V 2 1 DATA RS...

Страница 4: ...s brightness 4 V PHASE Adjustment When using two cameras or more the image on the monitor may roll vertically when switching sources This rolling can be minimized by adjusting this controller 5 DC IRI...

Страница 5: ...ccess function select Function Adjustment select DOWN Continue to press more than 2 seconds to access SUB MENU Select 6 PUSH BUTTONS AND THEIR FUNCTIONS Switch Name Function Adjustment select UP Main...

Страница 6: ...50 PAL 1 60 NTSC 1 250 1 500 1 10K 1 4K 1 2K 1 1K D N MODE AUTO B C G MANUA D N LEVEL HIGH LOW D N FIL ON OFF WIDE INT LL 0 45 1 OFF BLC1 BLC2 BLC3 BLC4 ATW1 ATW2 AWC R 0 6 B 0 6 HIGH LOW MID ID ID PO...

Страница 7: ...mode the camera will change to COLOUR mode and B W mode automatically according to a subject s brightness MANUAL When set to this mode the camera will remain in COLOUR or B W mode by MANUAL selection...

Страница 8: ...s 600TV lines If there is horizontal noise in B W mode set to ON 4 SHUTTER Selection of shutter speed from AUTO to 1 10K Sequentially contains AUTO 1 50 PAL or 1 60 NTSC 1 120 PAL or 1 100 NTSC 1 250...

Страница 9: ...trace white balance algorithm is designed to implement a perfect colour reproduction Colour temperature range is 2500o K 9500o K AWC The white balance is automatically adjusted within 3 seconds to the...

Страница 10: ...ddress from 001 to 199 for communication with remote controller 2 PROTOCOL Select protocol for communication with remote controller PELCO P PELCO D and ERNITEC are able to select 3 LANGUAGE Select lan...

Страница 11: ...more function B C G Control PREDTMSP 4 Alarm In 2 Alarm Out etc 1 Camera Control Box RJ 45 Pin define 2 Single Camera Installation 11 10 SYSTEM EXTENSIONS COAX CAT 5 PC RS 232 AC DC POWER ADAPTOR Fun...

Страница 12: ...with Switcher Box Optional To connect this camera with Switcher Box to obtain simple control function B C G Control and PREDTMSP 12 SYSTEM MATRIX RS 485 RS 232 PC CAM001 CAM199 CAM002 AC DC POWER ADA...

Страница 13: ...shutter speed which is set in OSD menu Note SW1 SW2 symbolise electronic switching PIR or manual switching Voltage free contact 13 H OFF GND OFF L ON GND ON Control Terminal PREDTMSP Pin 3 Pin 7 L ON...

Страница 14: ...era with PC and control it by PC software Optional A interface converter is required for converting RS 485 to RS 232 This converter is not a standard or optional accessory but it s easy to obtain in t...

Страница 15: ...Selectable Resolution CS Mount Only 480 TV Lines Horizontal Day Mode 12 Power Consumption 10W max with AI Lens 7 0 03 Lux F1 4 3200 o K AGC WIDE 10IRE C L Mode 0 004 Lux F1 4 3200o K AGC WIDE 10IRE B...

Страница 16: ...ettings recalled by pushing DEFAULT buttom NO 24 Iris Control Video Out DC Iris For Galvano Lens DC IRIS Output For Galvano Lens Camera ID OSD Control Default Setting D N Mode ITEM SPECIFICATION PAL N...

Отзывы: