background image

Wireless

 

FULL-HD

 Manhole Zoom Camera 

STV-4

MesSen Nord GmbH

22

6 Technical data

Weights

Camera unit with carbon telescopic rod 6.6 m:: 4.5 kg

Battery supply 

3 pieces Lithium standard cells camera,

1 lithium standard cell router

Ambient temperature

-5 ° C to max. 50 ° C

Camera / Optics

FULL-HD 1920(H) x 1080(V), Light sensitivity 0.01 Lux

30 x o 10 x digital zoom, Focus

Camera unit 

 protection degree IP 67 / not explosion-proof

Overpressure filling 0.5 bar with monitoring/warning indicator

Lightning

12 continuously dimmable LED spots

Interfaces

WLAN IEEE 802.11 b/g/n

Operation notes/Warning:

The camera unit of the STV-4 can be filled with overpressure; the internal pressure of the camera is

continuously monitored. The system is not explosion proof, which means it must never be used in the

hazardous area of flammable gases. Tanks and sewers, in which inflammable substances have been

stored  or  transported  or  in  which  emergence  of  flammable  mixture  of  gases  cannot  be  excluded  for

certain, must be emptied, cleaned and sealed before the camera is inserted. If necessary, introduce a

forced ventilation  by means of an  air exchange and clear the area of  application  with  a  suitable  gas

detection technology before using the camera.

The device complies with the valid EMC directives. The manufacturer reserves the right to make

changes in the sense of a technical development. Please observe the corresponding documentation

supplements. Please send any indications and suggestions to:

MesSen Nord GmbH

Zum Forsthof 2

D 18198 Stäbelow

Phone: +49 (0)38207/656-0

Fax: +49 (0)38207/656-66

Email: 

[email protected]

www.messen-nord.de

Содержание STV-4

Страница 1: ... GmbH Zum Forsthof 2 18198 Stäbelow Germany Phone 49 0 38207 656 0 Fax 49 0 38207 656 66 www messen nord de STV 4 Wireless FULL HD Manhole Zoom Camera Electronic sewer inspection Documentation Operating instructions ...

Страница 2: ...R 6 3 2 INSERT THE BATTERIES INTO THE CAMERA 7 3 3 PREPARATION STV4 CAMERA FILLING PRESSURE SUPPORT FOOT 8 4 CONTROL SOFTWARE STV4 10 4 1 SYSTEM REQUIREMENTS 10 4 2 SETTINGS AND PROGRAM PARAMETERS 11 4 3 PROGRAM INTERFACE AND OPERATION LIVE VIDEO 14 4 4 THE PICTURE GALLERY 18 4 5 THE VIDEO GALLERY 19 5 TROUBLESHOOTING 21 6 TECHNICAL DATA 22 ...

Страница 3: ...o the special lighting characteristic of the 12 high efficiency LEDs and the extremely high light sensitivity of the camera module used the STV 4 is starting with DN 150 suitable for zoom inspection of public drainage systems in the entire dimension range especially for large dimensions as well as shaft and special structures Depending on the dimensions range and the operating situation the STV 4 ...

Страница 4: ...otor driven rotatable in vertical direction Camera unit protection degree IP 67 not explosion proof Observe the warning Overpressure shield gas filling with permanent monitoring Standard lithium ion batteries for camera router Carbon telescoping rod standard 6 6m extendible Adjustable spring loaded support foot for exact positioning in the pipe centre according to DN200 DN800 WLAN router radio amp...

Страница 5: ...e camera rod system can be inserted laterally into the rotation support without disassembly and clamped at any working height STV4 RODSET Qicklock connecting rod set Total length 8 00 m Aluminium connecting rod set consisting of 4 individual rods of 2 0 m transport length 2 1 m with Twinloc pin locking STV4 CARB10 Extension STV4 CARB CARBOPT to 10 0 m total length Extension set for carbon telescop...

Страница 6: ...ch the router on via the non locking push button by keeping it pressed until it starts blinking approx 1 second To switch off press the push button briefly The router sends a confirmation via a quick blinking sequence of the LEDs The camera cannot be controlled if the router is not switched on The camera logs on to the router Then the control PC logs on to the WLAN of the router Now it can control...

Страница 7: ... is sufficient for daily operation in ECO mode see chapter 4 3 A tube can be illuminated for approx 1 5 hours with maximum lighting in the boost mode The camera is equipped with a locking switch used for switching on and off The camera is ready for use after approx 100 seconds The current charge status of the battery is indicated by the blinking frequency of the operating LEDs as well as in the st...

Страница 8: ...appropriate warning message is displayed on the user interface of the PC software The operation must be cancelled immediately Overpressure Filling connection If the value exceeds the pressure limit of 0 7 bar a warning message is also displayed In that case the filling pressure can be lowered by briefly opening the filling valve At normal operating conditions the pressure can increase due to inter...

Страница 9: ...alue according to the nominal pipe size to be inspected It is recommended to adjust a height value above the water line during the inspection of partially filled channels since the optical properties of the headlights and the camera are drastically restricted during the operation under water Furthermore a radio operation under water is technically not possible Adjustment of the support foot After ...

Страница 10: ...LL HD screen suitable for daylight conditions is recommended The FULL HD video signal requires at least Intel Core i3 Intel Core i5 is recommended 4 GB RAM SSD with at least 100 GB free storage capacity recommended for recording videos and photos You can access the latest version of the software with your login data on our website www messen nord de in the Download section If you do not have login...

Страница 11: ... be able to navigate properly during the subsequent viewing with the integrated picture gallery Parameters setting of tab window General The symbol size of the control buttons can be adjusted This may be necessary for a more comfortable use depending on the screen resolution and screen diagonal Furthermore the picture preview size can be defined in the picture gallery The video display can be in e...

Страница 12: ...n is too slow a reliable video playback can still be achieved by lowering the video resolution and dividing the data rate in half The ECO mode is a fully automatic control mode for the lightning to maximize the battery capacity The camera adjusts strongly illuminated areas of the image automatically by means of the aperture setting This would consume battery capacities unnecessarily The ECO mode h...

Страница 13: ...eration of the software it is simple and fast to switch between the different cameras and videos and photos can be recorded for documentation while the STV4 is located at the bottom of the shaft Predefined texts can be set on the tab window Text overlay to easily display or hide them during the video recording at the respective fixed position In addition logos as well and the GPS position can be d...

Страница 14: ...r the selection of the camera The button displays the available system cameras Click once on the icon to start the connection setup to STV4 Other configured system cameras can be selected by clicking on the camera symbols 1 to 3 Buttons for camera selection STV4 is the WLAN camera The live video and the control buttons for STV4 are displayed if the connection has been established successfully The ...

Страница 15: ...ge is reduced to the area within the buttons Video image without control button Click to re display The status displays are in the right upper corner of the screen The small battery symbol indicates the charge status of the router battery the big battery symbol indicates the charge status of the batteries in the STV4 Click once on this icon to display the temperature and the filling pressure in th...

Страница 16: ...enu Connect to STV4 and show video Start the video of a configured system camera or an USB video device Start picture gallery see chapter 4 4 Start video gallery see chapter 4 5 Display text insertion menu Display hide date time display hide predefined texts Program parameters settings for the system settings see chapter 4 2 Camera selection image galery video galery infinitely variable zoom progr...

Страница 17: ...e brightness is automatically adjusted to maximize the battery life Save video recording video files are consecutively numbered and stored in the subdirectory of the video library Save picture photos are consecutively numbered and stored in the subdirectory of the photo library Left adjusting wheel Motor driven angle adjustment of the camera pull upwards to raise the camera and pull down to lower ...

Страница 18: ...tures Zoom in a picture by double clicking on it close the picture again by clicking on it again The buttons have the following functions Closes the picture gallery and starts the last live video Deletes the last selected picture or the empty picture directory Switches to the previous picture directory Switches to the next picture directory After closing the picture gallery the live video of the l...

Страница 19: ... positions in the video can be selected via the slide control and position information times can be read and documented During playback pictures can be saved from the videos The buttons have the following functions Closes the video gallery and starts the last live video Select the video file to be replayed All videos in the directory are copied to the current playlist and can be selected quickly D...

Страница 20: ...o the previous video file in the currently selected directory Switches to the next video file in the currently selected directory Saves a picture in the directory for the current date After closing the video gallery the live video of the last selected video device will start ...

Страница 21: ... to ensure correct functioning of the camera Message Camera is connected video streaming has not yet been initialised requires about 60 sec after switching on The camera is still in start up phase Status LED is fading Try to start the connection setup to the camera again in about 60 seconds using the camera selection buttons when the status LED is blinking See chapter 4 3 Message Camera is connect...

Страница 22: ...itored The system is not explosion proof which means it must never be used in the hazardous area of flammable gases Tanks and sewers in which inflammable substances have been stored or transported or in which emergence of flammable mixture of gases cannot be excluded for certain must be emptied cleaned and sealed before the camera is inserted If necessary introduce a forced ventilation by means of...

Отзывы: