MesMed MM-155 Скачать руководство пользователя страница 2

 

 

 

 

Table of contest: 

1.

 

CHARACTERISTICS AND FUNCTIONS

 .............................................................................................. 2

 

2.

 

PLEASE READ BEFORE TURN ON THE DEVICE

 ................................................................................ 3

 

3.

 

CAUTIONS OF USE

 ........................................................................................................................... 3

 

4.

 

PRECAUTIONS

 ................................................................................................................................. 4

 

5.

 

PRINCIPLES OF OPERATION OF THE PULSOXYMETER

 ................................................................... 6

 

6.

 

TECHNICAL SPECIFICATION

 ............................................................................................................. 6

 

7.

 

DEVICE DESCRIPTION

 ...................................................................................................................... 6

 

8.

 

INSTALLATION OF BATTERIES

 .......................................................................................................... 7

 

9.

 

TAKING THE MEASUREMENT

 .......................................................................................................... 7

 

10.

 

CLEANING AND DISINFECTION

 ................................................................................................... 8

 

11.

 

SOLUTIONS OF EASY TROUBLES

 ................................................................................................. 8

 

12. 

STANDARDIZED MARKINGS

 ........................................................................................................ 8

 

 

 

1.

 

CHARACTERISTICS AND FUNCTIONS 

 

The high-quality finger pulse oximeter is designed for quick and non-invasive measurement of pulse 
and blood saturation in both adults and children over four years of age. By monitoring the saturation 
of hemoglobin with oxygen, various types of diseases and infections can be detected. For easier and 
more accurate measurement, our company offers you a pulse oximeter that measures both 
saturation and heart rate. It is extremely simple and convenient to use - just put it on your finger and 
press one button. 

It is a completely non-invasive and painless test that anyone can do on their own. It is enough for the 
patient to put one of the fingers into the sensor for diagnosis, and the display screen after a few 
seconds will show the directly measured value of the oxygen saturation of hemoglobin and the pulse. 

• Measurement of blood oxygen saturation (SpO2).

 

• Heart rate 

measurement. 

• Pulse intensity indicator.

 

• Bar and wa

ve graph - display of heart rate. 

• Clear, color, high

-quality TFT display. 

• Change the display direction.

 

• C

onvenient and easy one-key operation. 

• Fast measurement.

 

• Small size, light, easy to carr

y. 

• Very low battery consumption.

 

• Automatic switch

-off after 5 sec. 

• Lanyard.

 

CAUTION

MESCOMP TECHNOLOGIES reserves the right to make changes to the hardware and software 
resulting from technological progress. 
 

 

 

Содержание MM-155

Страница 1: ...USER MANUAL PULSE OXIMETER MM 155 OXYmed THANK YOU FOR BUYING OUR BRAND PRODUCTS WE WISH YOU A PLEASANT USE BEFORE USING THE DEVICE FOR THE FIRST TIME PLEASE READ THE USER MANUAL ...

Страница 2: ...ers you a pulse oximeter that measures both saturation and heart rate It is extremely simple and convenient to use just put it on your finger and press one button It is a completely non invasive and painless test that anyone can do on their own It is enough for the patient to put one of the fingers into the sensor for diagnosis and the display screen after a few seconds will show the directly meas...

Страница 3: ...he examined person must not have painted nails The subject s nails must not be too long If stable readings cannot be obtained stop measuring The device may not work properly for all patients If the screen displays abnormal indications during the test pull your finger out and reinsert it to restore normal operation Read the measured value when the pulse waveform is normalized and the pulse waveform...

Страница 4: ...nt of obvious damage It is not recommended to use the oximeter in a high electromagnetic frequency environment Do not use the oximeter during MRI and CT examinations Do not use the device on people allergic to rubber Do not use the oximeter in an environment with flammable gases such as certain flammable anesthetics Using in these conditions may cause an explosion Do not disassemble or change the ...

Страница 5: ...o not press the buttons on the front panel with sharp materials The flexible circuit connects the two parts of the device and should not be twisted or pulled Remove the batteries if the device is to be stored for more than a month otherwise leakage may occur The product lanyard is made of anti allergic material if the lanyard causes an allergic reaction stop using it Do not wear a lanyard around y...

Страница 6: ...ences in the optical properties of oxygenated and non oxygenated hemoglobin and calculates the degree of hemoglobin saturation with oxygen SpO2 Rys 1 6 TECHNICAL SPECIFICATION Display TFT Pulse wave display bar graph SpO2 measurement range 0 100 Accuracy 70 100 2 below 70 undefined Optical sensor red light wavelength 660nm 6 65mW infrared wavelength 880nm 6 75mW Heart rate measuring range 30bpm 25...

Страница 7: ...correctly inserting it may damage the device Only use new alkaline or rechargeable batteries in the device Using spent batteries may damage the device and void the warranty Before using the device for the first time or installing new batteries wait about 10 minutes for the device to reach its operating temperature Do not dispose of used batteries in a fire 9 TAKING THE MEASUREMENT 1 Open the clip ...

Страница 8: ...ore cleaning Clean the surface of the device before use First wipe the device with medical alcohol and then allow it to air dry or clean with a dry clean cloth For cleaning use a soft clean cloth dampened with equipment cleaner The device cannot be steam sterilized 11 SOLUTIONS OF EASY TROUBLES SpO2 and pulse rate cannot be displayed normally Place your finger correctly and try again SpO2 and hear...

Страница 9: ...azardous substances entering the environment from electrical and electronic waste Parts of the type BF SpO2 Pulse saturation with oxygen PR bpm Puls rate bmp Serial number Informations about manufacture Date of production Batch number IP 22 IP degree of protection of the device The CE symbol means that this product has undergone an appropriate conformity assessment procedure and meets the essentia...

Страница 10: ...10 Service office 03 948 Warszawa Ul Meksyńska 6 lok 102 E mail mescomptel mescomp pl tel 48 22 838 63 38 opening hours 7 30 15 30 date of actualization 12 03 2020 r ...

Отзывы: