NI1404-F0004
22
22.1
Power supply cable
- Check the condition and soundness of the electricity supply cable.
Every month
Hydraulic connection
control
- Check the condition and soundness of the water supply pipe and that the drain pipe is in good order.
- Make sure there are no leaks.
Every month
Water exchange in he
ice compartment
- Switch the appliance off and wait at least
4 hours
for defrosting.
- Disconnect the water network supply pipe and connect it to attachment
7
(fig 3,4 or 5)
- drain the water off for a few minutes to change the entire content of the compartment
- Reconnect the supply pipe correctly.
Every six mon-
ths
Replace the distribution
area UV bulb
(if present)
- Wear protection latex disposable gloves to avoid touching the lamp with your hands. The contact with
the skin can prejudice the duration of the lamp
- Enter the appliance near to the distribution area.
- Unscrew the tightening screw and remove the cover
(fig.22)
- remove the lamp and replace it with one of the same kind.
- mount again all the components in reverse
E v e r y 6 0 0 0
hours of functio-
ning (about 8
months)
Attention! The machine must not be tilted to empty the ice bank otherwise the water
reaches the electrical parts (fig. 22.1). It is essential to switch off the appliance and wait
about 4 hours for defrosting; open the casing of the machine and insert a pipe inside
the bank to suck the water present.
Attention! direct irradiation of the UV lamp is
dangerous both for the eyes and for the skin
GB
7
ROUTINE MAINTENANCE
17