INSTALLATION

Before drilling walls to fit the wall brackets, check that there are no cables or pipes buried in the wall.

Wall fixings must be appropriate for the construction of the wall.
The heater should be mounted horizontally and not be mounted directly below an electric outlet.
Position the heater to avoid curtains etc. being within 100 mm (4”) around the top and ends of the 
heater. Vinyl floor coverings and varnished floors require a minimum clearance of 120 mm to the 
underside of the heater. 

Heater types 

85820

 and 

85840

 are suitable for use in bathrooms or shower rooms.

For these installations the heater must be positioned so that a person in the bath or shower cannot 
touch switches and other controls.

Ensure that all packaging material is removed from the heater.

1.

Fix the wall bracket to the wall, allowing for the minimum clearance requirement (listed in the 
tables below). The wall bracket may also serve as a template (see drawing). Please ensure the 
wall bracket(s) is positioned in accordance with the drawing.

2.

Align the bottom of the heater onto the bottom hooks of the wall bracket. Raise the heater 
towards an upright position and secure the wall bracket safety strap(s), before finally securing 
the heater to the top wall brackets.

Cat. No.

Watts

L

A

85610

800W

1095

820

85620

1000W

1275

1000

85630

1200W

1545

1270

85640

1500W

1725

1450

Cat.No

Watts

L

A

85510

800W

645

370

85520

1000W

735

460

85530

1200W

915

640

85540

1500W

1095

820

85550

2000W

1365

1090

Cat.No

Watts

L

A

85820

600W

555

280

85840

1000W

735

460

Fig. 1
Mounting Positions

Содержание 85510

Страница 1: ...DA RF PANEL HEATERS Models Covered 400 mm High 85510 800W RF E408 85520 1000W RF E410 85530 1200W RF E412 85540 1500W RF E415 85550 2000W RF E420 200 mm High 85610 800W RF E208 85620 1000W RF E210 856...

Страница 2: ...L SUPPLY SUPPLIES before undertaking any maintenance work As the heater may have more that one electrical feed to the unit it is essential to ensure that all electrical supplies are isolated from the...

Страница 3: ...s are electric Panel Convectors with integral adjustable thermostats The thumb wheel thermostats are adjustable between 5 C to 30 C and positioned on the top right side facia These thermostatic heater...

Страница 4: ...mm Fixing Centres mm Other 85510 RF E408 800 230 240V 3 5 645 400 80 370 85520 RF E410 1000 230 240V 4 3 735 400 80 460 85530 RF E412 1200 230 240V 5 4 915 400 80 640 85540 RF E415 1500 230 240V 6 5 1...

Страница 5: ...If you do switch the heater OFF and get a qualified electrician to check it When young children elderly or infirm people are present the appliance should be adequately guarded DO NOT poke objects thr...

Страница 6: ...not touch switches and other controls Ensure that all packaging material is removed from the heater 1 Fix the wall bracket to the wall allowing for the minimum clearance requirement listed in the tabl...

Страница 7: ...ight set back which can be controlled by a remote timer and must be disconnected before service If the Night Set Back Control is not required the Black control cable can be ignored however the cable m...

Страница 8: ...the first time and may emit a harmless smoke for the first few minutes Rooms must be well ventilated during the commissioning period SAFETY DEVICE The heater has a built in safety device which discon...

Страница 9: ...er 2 Plug in the CREDASAVER into the left hand side of the thermostat housing 3 Adjust the thermostat knob B Fig 3 on the heater to the desired comfort temperature 4 Adjust the thermostat knob G Fig 5...

Страница 10: ...be chosen 7 Press the MODE key once more Now the LED marked MIN will light up and the minutes can be adjusted 8 After approximately 20 seconds the CREDASAVER returns to its normal operating mode and a...

Страница 11: ...11 PROGRAMME HEATING PROFILES Fig 7...

Страница 12: ...ation mode b From the display press the minus button on the CredaZone controller until the script tEst is displayed c At this stage the RF Receiver will begin with 3 flashes for every 3 seconds d Pres...

Страница 13: ...13 INSTALLING SETTING THE CREDAZONE CONTROLLER The following information is taken from the user instructions for the controller CredaZone1 CredaZone4...

Страница 14: ...nd hold the button for 3 to 5 seconds until the configuration mode CnF is displayed Press the RF Receiver button again until the CnF display is replaced by Set the CredaZone controller to the Auto set...

Страница 15: ...15 Setting Frost Protection Temperature Setting the Set Back Temperature...

Страница 16: ...16 PROGRAMMING THE CREDAZONE CONTROLLER Week Programming...

Страница 17: ...heck replace Two flashing horizontal lines appear on the Creda Saver plug in timer When installed for the first time or after a prolonged period of power failure the CREDASAVER will lose its settings...

Страница 18: ...tags to secure the element IMPORTANT The retaining tags provide electrical bonding of the element sheath to the main Earth connection It is vital that these tags securely grip the element After changi...

Страница 19: ...s fitted back in the same way 3 Remove the 2 terminals from the old thermostat and fit the new unit in the same way If enhanced access is required the plastic housing can be removed by pulling the top...

Страница 20: ...20 For spare parts contact Applied Energy Products Ltd National Spares Line 08700 102829...

Отзывы: