background image

21

TIMER TO
   CLOSE

TTC can be temporarily disabled by pressing RESET

button (located on the outside side of the control box)

when the gate is fully open. This will allow the gate to

remain open until another command is received. After

the next command to the operator, TTC returns to the 

previously set time period.

TTC OFF     MAXIMUM time
                     180 seconds

Содержание MGA600

Страница 1: ...N ONLY Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Phone Toll Free 1800 638 234 Chamberlain New Zealand Ltd PO Box 100 221 North Shore 0745 Phone Toll Free 0800 653 667 www go merlin...

Страница 2: ...t not be used if repair or adjustments are needed This safety alert symbol means Caution failure to comply with such an instruction involves risk of personal injury or damage to property Please read t...

Страница 3: ...Operation of your Gate Opener 23 Wiring Diagram 24 Control Inputs 25 Diagnostics 26 Troubleshooting 27 29 Spares 30 Warranty 31 Manual 1 2 3 4 5 6 7 1 MGA Carton Contents Motor x1 Release key x1 Hard...

Страница 4: ...led If the gate stop is on the ground the drive mechanism must also be installed at a height that is as low as possible so that it cannot twist the gate Use only parts of the gate frame for fixing pur...

Страница 5: ...is highly recomended DO NOT USE PLASTIC ANCHOR TO MOUNT THE BRACKET IN PLACE Step 2 Prepare the Motor Housing Taking note of the the Motor s orientation carefully knock out one of the four tap in the...

Страница 6: ...place using 13mm spanner not provided ART 7 Standard Base Plate ART 6 For Narrow Pillars or Spacer Step 4 Connect Motor to Loom Connect the Connection Cable in the motor as illustrated fig1 Step 5 Ma...

Страница 7: ...or Maglock be used on gates over 2m for added security against vandalism and adverse weather Disengage A 38 5cm 8 5cm 30cm C B 60 70cm 7 8 cm 90 max 10 cm Step 6 Fit the Gate Arm Use the Relase Key pr...

Страница 8: ...ocated where the risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier 11 For a gate operator utilizing a contact sensor such as an edge sensor a A hard...

Страница 9: ...ins voltage and low voltage control wires in the same conduit Low voltage motor cable sizes Voltage will drop along low voltage cables over long distances It is recommended to use cable with conductor...

Страница 10: ...e screws and open the box 3 Select Mounting Holes Select holes to be used for mounting and knock out using a screw driver and hammer 2 Remove the Control Board Disconnect reset button alarm and intern...

Страница 11: ...ET CLOSE CLOSE LIMIT LIMIT LEARN LEARN LIMITS LIMITS GATE 1 GATE 1 C69 C69 R329 R329 R27 R27 MOV2 MOV2 R4 R4 C2 C2 Q9 Q9 R9 R9 F8 F8 C73 C73 C72 C72 C71 C71 C7 C7 R42 R42 R423 R423 J24 J23 3 J24 J23 3...

Страница 12: ...e ma y mo ve at any time with out prio r war ning Do not let chil dren ope rate the gate or play inthe gate area This ent ranc e isfo r veh icle s only Ped estr ians mu st use sep arat een tran ce Wat...

Страница 13: ...T OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS DIAGNOSTIC GATE 1 J4 LEARN XMITTER MAGLOCK ON OFF F2 F6 U4 MAX FUSE OPEN C13 C4 Z1 10 D1 Z12 ACCESSORY POWER GATE 1 GRN WHT YEL BLU RED BRN Terminal blocks ca...

Страница 14: ...2M is included in the slave kit MGA600S for this function Before digging contact local underground utility locating companies Trench across driveway to bury the extension cable Use PVC conduit to prev...

Страница 15: ...14 Transformer...

Страница 16: ...intain safe access using small screws and wall plugs Using suitable cable 2 wire connect the beams to each other and to the control box Safety Sensor inputs see wiring diagram page 24 Use open photo a...

Страница 17: ...C75 C73 C73 C72 C72 C71 C71 C7 C7 C66 C66 C65 C65 C68 C68 C33 C33 F11 F11 R186 R186 R42 R42 R423 R423 J24 J23 3 J24 J23 3 A 32V A 32V 3 3 A 32V A 32V J21 J21 30 30 30 30 C64 C64 R22 R22 U2 U2 J18 J18...

Страница 18: ...Z1 R1 R1 R2 R2 K5 K5 F12 F12 Q9 Q9 R9 R9 F8 F8 Q6 Q6 Q1 Q1 J19 J19 R182 R182 C1 C1 1 1 C75 C75 C73 C73 C72 C72 C71 C71 C7 C7 C66 C66 C65 C65 C68 C68 C33 C33 F11 F11 R186 R186 R42 R42 R423 R423 J24 J23...

Страница 19: ...sed position To set the CAM switches disengage the motor using the Hex key provided Remove the top cover of the motor to allow access to the CAM located at the top of the motor keys to ac cess the cov...

Страница 20: ...19...

Страница 21: ...20 left right NOTES...

Страница 22: ...21 TIMER TO CLOSE T b w r t p TTC OFF MAXIMUM time 180 seconds...

Страница 23: ...22 C840...

Страница 24: ...he hood should be inserted into the side openings and turned approx 180 degrees until it cannot turn any further The drive has now been released To re engage it the key should be turned back to its or...

Страница 25: ...24 CAUTION 240 VAC Transformer...

Страница 26: ...T This input will command the gate to OPEN STOP CLOSE STOP in sequence RESET CONTROL INPUT The control box has a factory installed internal reset button These terminals are intended for use with a sin...

Страница 27: ...26...

Страница 28: ...27...

Страница 29: ...28...

Страница 30: ...nstantly sounds Double entrapment occurred Two successive obstructions were encountered while for 5 minutes Sounds moving the gate Press the RESET button and ensure that the gate path is clear of when...

Страница 31: ...1AART 1022SA 041AART 1025SA Antenna 001C3196 3 K001A6426 041AART 1002SA 041AART 1004 041AART 0003 041ABSC 1010 041AART 1005 041ABSC 1011 041AART 0063SA 041ABSC 0027 041ABSC 0017 041AART 0010 041AART 0...

Страница 32: ...er this Cham berlain Limited Warranty our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for c...

Отзывы: