Meritor Wabco System Saver 1000 Скачать руководство пользователя страница 16

 

Section 2
Troubleshooting & Testing 

 

MM-34
Page 12

Revised 11-02

 

Air leak at turbo 
cut-off valve vent.

Lip seal installed upside-down on 
piston. Lip must face UP (towards 
dryer).

Valve bore worn excessively.

Yes

Yes

Yes

Yes

Install lip seal correctly.

Inspect valve bore for wear. If a new 
turbo cut-off valve does not seal in 
a clean, lubricated bore, replace the 
air dryer.

Air dryer frozen 
(water collecting 
in base of dryer is 
freezing).

No electrical power to heater 
connector.

Low voltage to heater connector.

Heater assembly not working.

Wrong voltage air dryer used; i.e., 
12-volt air dryer used in a 24-volt 
system.

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Check for a blown fuse. Repair 
heater circuit.

 

NOTE:  

 

There must be power to the 

heater connector the entire time the 
vehicle’s ignition is 

 

ON

 

.

Repair cause of low voltage, such 
as poor electrical ground, bad 
connections, corroded wire splices, 
etc.

Replace heater assembly.

Replace with correct voltage air 
dryer.

No air pressure 
build-up in 
system.

Air dryer not plumbed correctly 
(connections reversed).

Wrong air line connected to dryer 
port 4.

Air governor not working 
properly.

Air system leaks, such as 
compressor discharge line, air 
dryer, reservoirs, brake or 
suspension valves, etc.

Air dryer leaks from purge valve.

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Ensure compressor discharge line 
is plumbed to air dryer port 1, and 
air dryer port 21 is connected to 
vehicle’s supply tank.

Ensure dryer port 4 line is 
connected to the “UNL” port of the 
air governor.

Inspect governor per 
manufacturer’s instructions. Repair 
or replace as needed.

Locate leak(s) and repair.

Refer to purge valve conditions 
listed in this chart.

Water in tanks; 
often following 
aftermarket 
installation or 
when dryer is a 
replacement for a 
competitive brand.

Pressure-controlled check valve 
not installed in correct tank or not 
installed at all.

Pressure-controlled check valve 
properly installed, but one-way 
check valve not removed.

Yes

Yes

No

No

Install pressure-controlled check 
valve in secondary tank.

Remove one-way check valve so 
that only the pressure-controlled 
check valve is installed between the 
secondary tank and supply tank.

Water, oil, or 
sludge in air 
system tanks.

Desiccant contaminated with oil.

Yes

Yes

Replace desiccant. Inspect 
compressor per manufacturer’s 
instructions.

Water in system 
tanks, everything 
else checks out 
okay.

Dryer not suitable for application.

Yes

Yes

Review application guidelines. For 
assistance, call ArvinMeritor’s 
Customer Service Center at 
800-535-5560.

 

Condition

Possible Cause

Conditions May Occur In:

Solution

Regeneration 
Style Air 
Dryers

Dedicated 
Purge Tank 
Air Dryers

Содержание System Saver 1000

Страница 1: ...System Saver Series Single Cartridge Air Dryers Maintenance Manual 34 Revised 11 02 System Saver Series 1000 1200E P U 1800E P U...

Страница 2: ...vice Information on our Web Site Enter meritorwabco com in your browser s address box for quick access to our web site At our home page click on literature to access our publications meritorwabco com...

Страница 3: ...o Cut Off Valve Assembly 18 Regeneration Valve Assembly 19 Purge Valve Assembly 20 Pressure Controlled Check Valve PCCV 21 Bypass Valve Pressure Relief Valve 22 Purge Silencer Muffler 23 Air Dryer Ass...

Страница 4: ...Notes...

Страница 5: ...desiccant regeneration U Indicates discharge line unloaded compressor E Indicates a Holset style compressor function G Indicates integral governor for air compressor control UP Indicates discharge lin...

Страница 6: ...siccant for the next cycle A typical Meritor WABCO System Saver 1200 or 1800 Series air dryer installation is illustrated in Figure 1 3 Illustrations for Combo Tank installations appear in Appendix II...

Страница 7: ...oisture also collects in the base of the dryer The governor turns the compressor off when system reaches cut out pressure approximately 120 psi When the compressor unloads the purge valve opens O Drye...

Страница 8: ...pendix II For special applications refer to Appendix III Figure 1 4 1002146b SYSTEM SAVER 1200 OR 1800 DESICCANT CARTRIDGE PRESSURE RELIEF VALVE PURGE VALVE ASSEMBLY REGENERATION VALVE ASSEMBLY FOR RE...

Страница 9: ...1 5 1696 1002147b SYSTEM SAVER 1000 1200 1200U DATE CODE FIRST 2 DIGITS BUILD WEEK LAST 2 DIGITS BUILD YEAR MANUFACTURING LOCATION CODE SYSTEM SAVER 1800 1800U SYSTEM SAVER 1200E PART NUMBER SYSTEM S...

Страница 10: ...Series and 1000 Series with date codes later than 0894 do not use a bypass valve Figure 1 8 1002150a Figure 1 9 Outlet Check Valve A valve located in the outlet port port 21 of the air dryer It preven...

Страница 11: ...r base that remains open during a compressor unload cycle It allows collected moisture condensation and contamination to be expelled from the air dryer during a purge cycle Figure 1 12 1002154a Figure...

Страница 12: ...harger boost pressure during a compressor unload cycle thereby maintaining boost pressure for maximum engine horsepower Figure 1 14 There is no spring in the turbo cut off valve assemblies used on U S...

Страница 13: ...instructions Interval Required Action Weekly Ensure dryer purges when compressor unloads Weekly or as recommended by the manufacturer Drain purge tank dedicated purge tank dryers Weekly or as recommen...

Страница 14: ...ring fully into groove Slight leak from purge valve After several hours the supply tank may be empty Outlet check valve not seating or regeneration valve not shutting off regeneration airflow Yes No R...

Страница 15: ...e air system leaks Excessive air system demands Outlet check valve not seating Regeneration valve not shutting off properly Air governor has less than 16 psi range Leaking air compressor unloader s Ye...

Страница 16: ...n valves etc Air dryer leaks from purge valve Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Ensure compressor discharge line is plumbed to air dryer port 1 and air dryer port 21 is connected to vehicle s su...

Страница 17: ...nnection that contains pressurized air Check the connections to see if soap solution bubbles No Soap Bubbles Connections are sealed properly Soap Bubbles Appear Connections are NOT sealed properly To...

Страница 18: ...and air system problems Clean the Regeneration and Outlet Check valves Disconnect the compressor line from the air dryer Dryer Port 4 Check the compressor and governor per the manufacturer s recommend...

Страница 19: ...ly not working internal short or open circuit Outlet Check Valve Air continues to flow from purge valve after purge cycle but stops flowing when the compressor load cycle begins Valve is stuck in the...

Страница 20: ...the vehicle with safety stands Do not work under a vehicle supported only by jacks Jacks can slip and fall over Serious personal injury can result Desiccant Cartridge 1 Replacement kit contains one ca...

Страница 21: ...ayer of grease to the valve bore and the O ring 6 Install the new valve body with its long end in the bore 7 Install the new spring with its small end around the Y shaped fins on the valve body 8 Inst...

Страница 22: ...rings and seals 2 Remove the snap ring The cover and spring may fall out of the bore when the snap ring is removed 3 Remove the desiccant cartridge as described above Use a wooden stick to push the pi...

Страница 23: ...lts and the valve housing assembly When you remove the housing the spring and cap will fall out 3 Remove the rubber diaphragm 4 Clean and inspect the diaphragm lip groove If the groove is damaged so t...

Страница 24: ...2 4 Remove washer and O rings from the base 5 Clean and inspect the valve bore If the bore is damaged so that a tight seal cannot be maintained replace the air dryer 6 Apply a thin layer of grease to...

Страница 25: ...ve and remove the valve from the tank and hex nipple pipe fitting 3 Install the new valve O Whatever orientation up or down the valve is in when it is tight is acceptable as long as the arrow is point...

Страница 26: ...t the front Port 1 of the dryer On dryers with date codes later than 2295 the pressure relief valve is located at the side of the dryer Port 31 Figure 3 18 2 Unscrew and remove the old pressure relief...

Страница 27: ...System Saver Air Dryer 1 Drain all pressure from the air system Disconnect all air lines Use markers to label the lines for proper reinstallation 2 Disconnect the heater electrical plug from the heat...

Страница 28: ...k to see if the pressure controlled check valve is installed backwards If so install correctly and re test If not check for air leaks in the secondary air system If no significant air leaks are found...

Страница 29: ...ystem supply tank which triggers the compressor unload cycle Dedicated Purge Tank A separate air tank used exclusively for holding air used in an air drying cycle This tank eliminates the need for a r...

Страница 30: ...flow of air back from the supply tank to the air dryer O Feed purge valve by a direct line from the air governor Operating Environment Requirements Discharge Line O Diameter from compressor to air dr...

Страница 31: ...ing 2 minutes maximum Occasional three times per day maximum 7 minutes Compressor unloaded time Minimum for purge cycle 20 seconds Maximum duty cycle Compressor on time total running time 30 Discharge...

Страница 32: ...Series air dryer WITHOUT an Econ valve and your application requires one Meritor WABCO recommends installing the System Saver 1200E Figure A 1 PURGE VALVE EXHAUST COMPRESSOR DISCHARGE LINE COMPRESSOR...

Страница 33: ...w and remove all of the lines from the Econ valve at the air dryer inlet port Figure A 3 Figure A 2 1002187b PURGE VALVE EXHAUST COMPRESSOR DISCHARGE LINE COMPRESSOR CONTROL PURGE PORT COMPRESSOR INTA...

Страница 34: ...r D Using a wrench loosen and remove the Econ valve from the banjo fitting E Remove the banjo fitting and metal washer F Clean the valve surface area thoroughly before replacement 2 Install the replac...

Страница 35: ...found at other locations 1 Check the vehicle s air system to determine if an alcohol evaporator is installed 2 If an alcohol evaporator is installed in the air system check for a bypass line connecte...

Страница 36: ...SOR INTAKE LINE PRESSURE CONTROLLED CHECK VALVE SUPPLY TANK WET SYSTEM RESERVOIR INTERNAL CHECK VALVE DRYER INLET PORT UNLOADER LINE RESERVOIR TO GOVERNOR LINE 1800 1200 SYSTEM RESERVOIR CHECK VALVE S...

Страница 37: ...OMPRESSOR INTAKE LINE PRESSURE CONTROLLED CHECK VALVE SUPPLY TANK WET SYSTEM RESERVOIR INTERNAL CHECK VALVE DRYER INLET PORT UNLOADER LINE 1800 1200 SYSTEM RESERVOIR SUPPLY LINE DRYER OUTLET PORT ALTE...

Страница 38: ...stem Saver Series Single Cartridge Air Dryer Component Replacement Guide Dedicated Purge O RING HEATER ASSEMBLY DESICCANT CARTRIDGE PRESSURE RELIEF VALVE PURGE VALVE ASSEMBLY OUTLET CHECK VALVE ASSEMB...

Страница 39: ...commended torque See Pressure Relief Valve in Section 3 REGENERATION VALVE ASSEMBLY REGENERATION STYLE DRYERS ONLY Remove old assembly and diaphragm Clean diaphragm lip groove Install replacement diap...

Страница 40: ...Notes...

Страница 41: ...Notes...

Страница 42: ...Notes...

Страница 43: ......

Страница 44: ...in effect at the time the publication was approved for printing and is subject to change without notice or liability Meritor WABCO reserves the right to revise the information presented or discontinu...

Отзывы: