27
5.3
CONTROL SYSTEM FUNCTIONS
5.3.1
Control Functions
The controls on this panel are intended to be used
only as a backup resource. All of the functions
of the seed tender can more easily be controlled
using the handheld remote transmitter.
Work Lights (1)
This switch controls the (4) work lights on the
tender.
Gate Select (2)
This switch selects the active slide gate. The
active gate is displayed on the wireless remote
control.
Gate Open/Close (3)
This switch opens and closes the active slide
gate. Press and hold the switch UP to open the
slide gate; press and hold the switch DOWN to
close the slide gate. The opening can be varied
to provide the desired fl ow rate of seed onto the
conveyor belt.
Auto Fold/Unfold (4)
Press and hold this switch to fold/unfold the incline
conveyor
Engine Start/Stop (5)
Press and hold this switch up until the engine
starts. The key must be in the ON position for the
engine to start Also set the choke lever on the
engine when starting the engine. Press and hold
this switch down to turn OFF the engine.
Conveyor On and Off (6)
This toggle switch starts and stops the conveyor
belts. The two conveyor belts are automatically
synchronized. Press the toggle switch UP to start
the conveyor. Press the toggle switch DOWN
to stop the conveyor. The incline conveyor belt
will not operate unless the incline conveyor is
unfolded.
Conveyor Rotate Left and Rotate Right (7)
This switch rotates the conveyor to the right or
left. Press the switch down to rotate the conveyor
towards the left of the unit. Press the switch up to
rotate the conveyor towards the right of the unit.
Conveyor Swing Over and Back (8)
This switch raises and lowers the conveyor. Press
the switch UP to raise the conveyor. Press the
switch DOWN to lower the conveyor.
Slide Right/Center (9)
Press and hold this switch to position the incline
conveyor to the center (under the underbin
conveyor) or to the right (transport position).
EMERGENCY STOP (10)
Pressing this button will cause all functions to stop
and shut off the engine.
To reset the Emergency Stop, fi rst eliminate the
condition that caused the operator to use the
Emergency Stop. Then rotate the knob clockwise
and allow it to reset itself.
The unit will not start with this button pressed in.
5.3.2
Control System Compliance
Information
This equipment has been tested and found
to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference. This
equipment generates radio frequency energy
and if not installed and used in accordance with
the instructions, may cause harmful interference
to radio communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to the reception of other
electronics, which can be determined by turning
the equipment off and on, DO NOT operate this
equipment around those devices.
This equipment has been certifi ed to comply with
the limits for a Class B computing device, pursuant
to FCC Rules. In order to maintain compliance
with FCC regulations, shielded cables must be
used with this equipment. Operation with non-
approved equipment or unshielded cables is
likely to result in interference to electronic device
reception. The user is cautioned that changes and
modifi cations made to the equipment without the
approval of the manufacturer could void the user’s
authority to operate this equipment.