MXFix™ (Batch Export, Re-Wrapping) : Final Check Meter
Page 102
•
Measure EBU R-128/ITU.1770 (ATSC) compliant loudness levels of any stereo or surround channel with
Merging’s Final Check technology
•
Generate a loudness level report file in .xml format with Final Check
•
Correct MXF aspect ratio metadata
•
Correct audio word length values
•
Correct audio track counts to fit MXF hardware manufacturers’ standards
•
Encode Dolby E audio streams
•
Wrap it all to a new video file
•
Push that newly wrapped video file to an Output Folder for deployment
•
Erase or move the original file away from the watch folder for archiving
MXFix Quick Procedure
1.
Start the process by going to:
File > Export >
MXFix
or
[Alt + M]
This opens the
MXFix Folders
dialog. (See below for full details.)
2.
Use the Input Folder and Output folder
...
buttons to open browsers to select a suitable Input/Output pair of
folders. The Input folder is the “
Watch
” folder.
3.
Click on the
Add Folder Pair
button to add the folder pair to the main frame.
4.
Click on the pair you’ve just added to select it.
5.
Click on the
Settings
button to open the
MXFix Wrapper
dialog. (See below.)
6.
Make any necessary changes to settings
7.
Click on the
OK
button to save the settings and exit the dialog.
8.
Click on the
OK
button to start the process and close the dialog.
Note:
The
Input Folder
must be different to the Input Folder in any existing Folder Pair when
adding new Folder Pairs.
If you attempt to add a Folder Pair with the same Input Folder as an existing Folder Pair the
Add
Folder Pair
button will not work.
Each pair of Input and Output folders defined will have its own unique settings associated with
the Input folder defining what tasks will be performed on the video files placed in that folder.
When
Continuous Watch
mode is active :
Processed files will be placed in a new sub-folder
DONE
on the path selected, or will be deleted if
Delete Original after reset
is active.
When the MXFix process is running in “single-shot”mode. I.e.
Continuous Watch
is NOT selected
then all VCube functions other than
Cancel
and
Cancel All
are locked out until the process is
complete.
Cancel
Cancels processing of the current file and continues with the next. (If any.)
Cancel All button
Stops the MXFix process.
Содержание VCube
Страница 1: ...USER MANUAL User Manual...
Страница 9: ...Page 9 Document revision 22 Date 28th November 2012...
Страница 13: ...Introduction VCube Keys Options Page 13 VCube Versions...
Страница 196: ...Output View Output Page Diagnostic Tools Page 196 Audio Meters Shows audio Playback levels Output Page Audio Meters...
Страница 231: ...Appendices HDTV Recorded Media Page 231 HDTV Recorded Media SDTV Recorded Media...
Страница 264: ...Appendices Pro Tools VCube Operation Page 264 Pro Tools VCube Operation...
Страница 270: ...Appendices Pro Tools and VCube Page 270...
Страница 273: ...Appendices Pro Tools and VCube Page 273...
Страница 274: ...Appendices Pro Tools and VCube Page 274...
Страница 275: ...Appendices Sony 9 Pin RS422 Wiring Chart Page 275 Sony 9 Pin RS422 Wiring Chart...
Страница 276: ...Appendices Sony 9 Pin RS422 Wiring Chart Page 276...
Страница 277: ...Appendices Sony 9 Pin RS422 Wiring Chart Page 277...
Страница 278: ...Appendices Sony 9 Pin RS422 Wiring Chart Page 278...