Audio Outputs
The Sphynx unit supports up to eight outputs. The outputs format is determined by the type of output modules
installed in the Sphynx. Currently the Sphynx supports the following output modules:
24 bit analog line outputs (up to 48 kHz)
24 bit analog line outputs (up to 96 kHz)
24 bit AES-EBU output (up to 96 kHz)
Sphynx can accommodate up to 4 output modules, each having two discreet outputs.
OUTPUTS
1
2
3
4
5
6
7
8
AES-EBU 1/2
AES-EBU 3/4
AES-EBU 5/6
AES-EBU 7/8
LINE
LINE
LINE
LINE
LINE
LINE
LINE
As mentioned above, the output connectors are mapped in pairs to the corresponding output modules.
See Chapter 5 on how to make audio connections.
Analog Outputs
When using analog output modules, the corresponding output XLR connectors are adjustable, ba 4 dBu
nominal line level (headroom 20dB) analog outputs.
AES-EBU Outputs
When using AES-EBU output modules, the corresponding output XLR connectors (only those XLRs corresponding
to odd line outputs should be used) are balanced AES-EBU outputs.
AES-EBU Ref. Input
AES-EBU REF
This XLR input accepts any balanced AES-EBU signal up to 48 KHz.
This reference is used primarily when the Sphynx is placed into
AES
sync mode.
When the Sphynx is set in ‘x2’ SR mode, this input will only accept an AES-EBU signal of FS/2 sample rate.
For example, when set to 96 KHz, the Sphynx would lock on a 48 KHz AES-EBU signal present at this input.