Section 4 - Setup and Calibrations
90-8M0109374
eng
JUNE 2016
Page 75
In addition to the PCM selections, there are options to select either the TAB—trim tab interface module, or the TVM—thrust
vector module, to send tab data to the VesselView.
Drive assignment options
a -
PCM0 = starboard or starboard outer
b -
PCM1 = port or port outer
c -
PCM2 = starboard inner or center
d -
PCM3 = port inner
61661
Tab calibration allows the operator to put the tabs in their uppermost and lowermost positions and record the percentages. This
is useful for determining the true 0° trim position—the point at which the tabs are parallel with the bottom of the vessel.
Correctly calibrated tabs will show an accurate position of the sliders on the screen.
To calibrate the tabs, trim the tab parallel to the hull, record the reading, this will be the tabs actual 0%. Trim the tab all the way
down, record the reading, this will be the tabs actual 100%. Select Save to keep the new calibrated tab data.
a -
Select the number of points of
calibration desired
b -
Position of the tabs for
recording purposes
c -
Select save to keep the
calibration
a
a
a
b
b
b
c
c
d
60056
a
61669
a
b
c
Содержание VesselView 502
Страница 1: ...OPERATION MANUAL VesselView Link 502 and 702 For All Multi Function Displays Using the VesselView Link...
Страница 2: ...2016 Mercury Marine VesselView 502 and 702 8M0109374 616 eng...
Страница 3: ......
Страница 57: ...Section 2 Initial Screens and Setup Wizard Page 52 90 8M0109374 eng JUNE 2016 61737...
Страница 75: ...Section 3 Autopilot Features and Operation Notes Page 70 90 8M0109374 eng JUNE 2016...
Страница 105: ...Section 5 Warning Alarms Page 100 90 8M0109374 eng JUNE 2016 61779 61780...