TROUBLE CODE DIAGNOSTICS - 7.4L MPI
SERVICE MANUAL NUMBER 23
Page 5G-42
90-861326--1 MARCH 1999
Code 15 (3 of 3): Engine Coolant Temperature (ECT) Sensor Circuit (Scan)
High Temperature Indicated
STEP
ACTION
VALUE
YES
NO
PROCEED TO
4
Trouble code 15 is intermittent. Locate and re-
pair intermittent faulty connections. Refer to
“Diagnostic Aids.”
–
–
5
Locate and repair short to ground in CKT 410.
If a problem is found, repair as necessary.
Was
a problem found?
–
Verify
Repair
Step 7
6
Repair faulty ECT sensor.
Is action complete?
–
–
7
Repair faulty ECM connections or replace
faulty ECM.
Is action complete?
–
–
ENGINE COOLANT TEMPERATURE SENSOR CHART
ECT Sensor
Temperature - to - Resistance Values (Approximate)
°
F
°
C
OHMS
210
160
100
70
40
20
0
-40
100
70
38
20
4
-7
-18
-40
185
450
1,800
3,400
7,500
13,500
25,000
100,700
Downloaded from
https://needmanual.com/
Index