STARTING SYSTEM
SERVICE MANUAL NUMBER 23
Page 4A-4
90-861326--1 MARCH 1999
Specifications
Starter Specifications
Direct Drive Starter Motor
Delco Iden-
tification
Engine
Rotation
No Load Test
Brush
Spring
tification
Number
LH
Volts
Min.
Amps
Max.
Amps
Min.
rpm
Max.
rpm
Tension Oz.
(Grams)
10455602
LH
10.6
70
120
5400
10800
56-105
(1588-2976)
Pinion Clearance
.010-.140 (0.25-3.5 mm)
Commutator End Frame Gap
.025 Max. (0.6 mm Max.)
Battery Cable Recommendations
IMPORTANT: Terminals must be soldered to cable ends to ensure good electrical
contact. Use electrical grade (resin flux) solder only. Do not use acid flux solder, as
it may cause corrosion and failure.
Cable Length
Cable Gauge
Up to 3 - 1/2 ft (1.1m)
4
(25 mm
2
)
3-1/2 - 6 ft (1.1-1.8m)
2
(35mm
2
)
6 ft - 7-1/2 ft (1.8-2.3m)
1
(50mm
2
)
7-1/2 - 9-1/2 ft (2.3-2.9m)
0
(50mm
2
)
9-1/2 - 12 ft (2.9-3.7m)
00
(70mm
2
)
12 - 15 ft (3.7-4.6m)
000
(95mm
2
)
15 - 19 ft (4.6-5.8m)
0000
(120m
2
)
Both positive (+) and negative (–) cables
Torque Specifications
Fastener Location
lb-ft
Nm
Starter Motor To Block
50
68
All Other Fasteners
Tighten Securely
Lubricants / Sealants / Adhesives
Description
Part Number
Quicksilver Liquid Neoprene
92-25711--3
SAE 10W Oil
Obtain Locally
SAE 20W Oil
Obtain Locally
Downloaded from
https://needmanual.com/
Index