MAINTENANCE
61
Tube Ref
No.
Description
Where Used
Part No.
95
2-4-C with
Teflon
Tensioner pulley grease fitting
92-802859A 1
Flushing the Cooling System
Flushing the cooling system is essential after each use in saltwater,
after the boat has run aground, or when the overheat warning horn
sounds. When using the flushing attachment, ensure that the water
is turned all the way on and flowing through the engine before
starting.
IMPORTANT: When using the flushing attachment do not run the
engine above idle.
!
CAUTION
Never start or run the jet drive without water circulating through
the cooling system to prevent damage to the unit.
a -
Flushing attachment (hull
mount)
b -
Flushing attachment
(engine compartment
mount)
1. Locate the flush adapter in the boat. Some boats may have
the adapter mounted in the hull or mounted in the engine
compartment.
2. With engine "OFF," remove the cap from the flush adapter and
attach a water hose.
IMPORTANT: Do not run the engine above idle when flushing.
3. Turn the water on all the way. Start the engine and flush the
engine block for at least 10 minutes.
a
b
5469