Refit each of the burner bases; make sure to reconnect the
ignition leads and slide the insulating sleeves in place. Refit
the brass venturis.
Tap Adjustment
Remove the service panel above the control taps.
Turn the bypass screw on each control clockwise to the stop
(Fig.8-5)
.
Repeat for all burner control taps.
Refit the service panel and then refit the control panel.
Reassembling to Liquid Propane Gas
Centre Burner
IMPORTANT:
If you are converting to LP Gas the large ring
in the conversion kit MUST be fitted to the centre burner.
Fit the large ring (if required). Screw in the hexagon headed
venturi but to make fitting the outer burners easier do not
fully tighten yet
(Fig.8-6)
.
Outer Burners
Screw in the hexagon headed venturis
(Fig.8-7)
but to make
fitting the other burners easier do not fully tighten yet.
Reassemble all the burners with the venturi tubes and evenly
tighten.
Refit the burner heads, making sure they are reassembled in
the correct way on the burner bodies
(Fig.8-8)
.
Refit the pan supports.
Stick on Label
Stick the appropriate label on to the data badge to indicate
the gas the appliance is now set for.
Pressure Testing
The gas pressure can be measured at the pressure test point
on the gas connection block.
Connect the pressure gauge. Turn on and light one of the
hotplate burners.
See the data badge for test pressures.
Turn off the burners and remove the pressure gauge.
n
n
Check the appliance is gas sound.
n
n
Check the operation of all the burners.
Fig.8-6