background image

Mercury Security 

©

 2013   

SR10k    Doc. 10107-0007   

Rev 1.08  

  Page 

2

          

Table of Contents

Section Page

Overview 3

Quick Start and Confi guration Planning 

5

Programming Guide 

6

Operating Mode Specifi cations 

10

Mode 1: Basic Access Control with Door Monitoring 

10

Mode 2: Restricted Access Control with Door Monitoring 

11

Mode 3: Access Control and Alarm Panel Control 

12

Mode 4: Restricted Access and Alarm Panel Control 

13

Mode 5: "Supervisor" Controlled Restricted Access 

14

Mode 6: "Two Door" Access Control 

14

Mode 7: Access Control with "Door Bell" Feature 

15

Mode 8: Dual Output Toggle on Valid Access 

15

Installation 16

Maintenance 17

Specifi cations 

17

Dimensions and Typical Confi guration Diagrams 

18

  Mercury 

Security 

 

         2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755

 

 

 

     (562) 986-9105, FAX (562) 986-9205

                            www.mercury-security.com

This device complies with part 15 of the FCC Rules. Opera-
tion is subject to the following two conditions: (1) This device 
may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that 
may cause undesired operation.

Содержание SR10k

Страница 1: ...Mercury Security 2013 SR10k Doc 10107 0007 Rev 1 08 Page 1 SR10k Mag Stripe Access System Users Guide www mercury security com 2355 MIRA MAR AVE LONG BEACH CA 90815 1755 562 986 9105 FAX 562 986 9205...

Страница 2: ...ed Restricted Access 14 Mode 6 Two Door Access Control 14 Mode 7 Access Control with Door Bell Feature 15 Mode 8 Dual Output Toggle on Valid Access 15 Installation 16 Maintenance 17 Specifications 17...

Страница 3: ...s mode allows the use of any magnetic stripe card with standard track 2 encod ing such as the MS SR10CC25 pre encoded packs of 25 cards or cards from many other access systems or even bank cards Store...

Страница 4: ...ection of these functions intended for a specific application The Operating Modes are described in detail later in this document Changing the Operating Mode resets the door strike held open and auxili...

Страница 5: ...nes the installation wiring details and User Level assignment Lost Master Card Follow the steps outlined below to set a new Master Card in case the current Master Card is lost remove power from the SR...

Страница 6: ...card using the card 1 2 select Command 12 user card read the card to be deleted from that slot Command 13 Delete a range of cards 1 3 select Command 13 0 9 0 9 select the first user number to delete...

Страница 7: ...ct the user level 1 3 0 1 0 9 0 9 0 9 enter the first user slot to activate 0000 through 1599 0 1 0 9 0 9 0 9 enter the last user slot to activate 0000 through 1599 Command 23 Delete a range of cards...

Страница 8: ...block mode card database 1 600 users may take up to 1 minute The completion of a successful transfer is indicated with the long beep A transfer error condition is signalled with three short beeps alo...

Страница 9: ...ase Mode 4 The Block Number Command 94 must be set for Block Database Mode operation 5 In Facility Code Database Mode the digit count specifies the the number of card digits to read and verify For exa...

Страница 10: ...d will pulse Output K1 no effect if the door is unlocked A upward read will toggle the state of Output K1 locking or unlocking the door Configuration Input assignments Input I1 is connected to a door...

Страница 11: ...f Input I2 User Level 2 and 3 A downward read will pulse Output K1 no effect if the door is unlocked A upward read will toggle the state of Output K1 locking or unlocking the door Configuration Input...

Страница 12: ...ses Output K2 allowing the momentary closure to simulate a key switch input to an alarm panel User Level Specifications User Level 1 Both downward and upward read will pulse Output K1 User Level 2 and...

Страница 13: ...to simulate a key switch input to an alarm panel User Level Specifications User Level 1 Cards having this User Level are rejected if the contact on Input I2 is open If the contact on Input I2 is close...

Страница 14: ...to Output K2 and functions as the access control input User Level 1 users are valid only when a closed contact is presented to this input Upper LED assignment The upper LED follows Input I2 displaying...

Страница 15: ...efinition Description This mode is intended for applications where the outputs need to be toggled instead of the standard momentary pulse operation Both outputs are toggled Level 1 users alter the out...

Страница 16: ...ESD electrostatic discharge interfering with the operation of the reader the reader casing shall be grounded This can be accomplished be tying the mounting bracket to earth ground locally e g grounded...

Страница 17: ...from a number of sources e g Clean Team Co 800 888 8830 www cleanteam com KIC Products 207 514 7030 www kicproducts com System ID 1 888 648 4452 www systemid com The reader exterior surface is covere...

Страница 18: ...any other warranties implied warranties and expressly excludes and disclaims all implied warranties of merchantability of fitness for a particular purpose Returns must be accompanied by a Return Mater...

Страница 19: ...l RS 485 termination jumper J4 on the first and last units only 1 2 3 4 5 6 7 8 J2 TB1 GND J3 TR TR VO D0 DAT GND D1 LED DAT BZR TB4 J4 B A U1 J6 TB3 TB2 K2 K1 I1 I1 I2 I2 GND VIN C NC NO C NO NC K2 K...