background image

 

Mercury Security © 2015 

EP4502 

DOC  10107-0039  

REV 1.02 

 Page   7 

 

LED 

DESCRIPTION 

IN1 

Input IN1 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

IN2 

Input IN2 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

IN3 

Input IN3 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

IN4 

Input IN4 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

IN5 

Input IN5 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

IN6 

Input IN6 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

IN7 

Input IN7 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

IN8 

Input IN8 Status: OFF = Inactive, ON = Active, Flash = Trouble.  See Note 1. 

K1 

Relay K1: ON = Energized 

K2 

Relay K2: ON = Energized 

K3 

Relay K3: ON = Energized 

K4 

Relay K4: ON = Energized 

Note  1:    If  this  input  is  defined,  every  three  seconds  the  LED  is  pulsed  to  its  opposite  state  for  0.1 

seconds, otherwise, the LED is off. 

13. Specifications: 

The EP4502 is for use in low voltage, Class 2 Circuits only 

The installation of this device must comply with all local fire and electrical codes

 

Primary Power: 

12 to 24 Vdc ± 10 %, 500 mA maximum (reader current not included) 

Memory and Clock 
Backup Battery: 

3 Volt Lithium, type BR2325, BR2330 or CR2330 

Host Communication: 

Ethernet: 10Base T/100Base-TX 

SIO Communication 

Two each, 2-wire RS-485, 2,400 to 115,200 bps, asynchronous, half-duplex,  
1 start bit, 8 data bits, and 1 stop bit 

Inputs: 

Two dedicated for tamper and UPS fault monitoring 
Eight for door position monitoring, request to exit or alarm contacts 

Relays: 

Four each: Form-C, 5 A @ 30 Vdc, resistive 

Reader Interface: 

Reader Power: 

12 Vdc ± 10 % regulated, current limited to 180 mA for each reader 

(jumper selectable) or 

12 to 24 Vdc ± 10% (input voltage passed through) current limited to 180 mA 
for each reader 

Data Inputs: 

TTL  compatible  inputs,  magnetic  stripe  and  Wiegand  standards  supported.  
Maximum cable length: 500 ft. (152 m) 

RS-485 Mode: 

9,600 to 38,400 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 
stop bit.  Maximum cable length: 2000 ft. (609.6 m) 

LED Output: 

TTL levels, high>3 V, Low<0.5 V, 5 mA source/sink maximum 

Buzzer Output: 

TTL levels, high>3 V, Low<0.5 V, Low=Active, 5 mA source/sink maximum 

 

 

Содержание EP4502

Страница 1: ...al signaling standards and also provides tri stated LED control and buzzer control one wire LED mode only Four Form C relay outputs may be used for strike control or alarm signaling The relay contacts...

Страница 2: ...NO Normally Open Contact Input 4 IN4 C Common IN4 NC Normally Closed Contact TB6 Input 5 IN5 Out 4 NO Normally Open Contact IN5 C Common Input 6 IN6 NC Normally Closed Contact IN6 TB7 Input 7 IN7 IN7...

Страница 3: ...fault parameters after OEM code has been changed Recover from database corruption causing EP4502 board to continuously reboot If clearing the memory does not correct the initialization problem contact...

Страница 4: ...the communication channel 7 Reader Wiring Each reader port supports Wiegand magnetic stripe and 2 wire RS 485 electrical interfaces Power to the reader is selectable 12 Vdc VIN must be greater than 2...

Страница 5: ...door lock mechanisms or alarm signaling The relay contacts are rated at 5 A 30 Vdc dry contact configuration Each relay has a Common pole C a Normally Open pole NO and a Normally Closed pole NC When...

Страница 6: ...tions are available to disable SNMP Zeroconf discovery as well as the web configuration module itself Additionally data encryption can also be enabled over the host communication port 12 Status LEDs P...

Страница 7: ...f this device must comply with all local fire and electrical codes Primary Power 12 to 24 Vdc 10 500 mA maximum reader current not included Memory and Clock Backup Battery 3 Volt Lithium type BR2325 B...

Страница 8: ...ury Security assumes no responsibility for products damaged by improper handling or installation This warranty is limited to the repair or replacement of the defective unit There are no expressed warr...

Отзывы: