background image

 

Mercury Security © 2015 

EP4502 

DOC  10107-0039    

REV 1.02 

 Page   1 

www.mercury-security.com 

2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205 

This  device  complies  with  part  15  of  the  FCC  Rules.  
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  this 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation. 

EP4502 Intelligent Controller 

with Two Reader Interface 

Installation and Specifications: 

1.  General 

The EP4502 intelligent controller provides decision making, event reporting, and database storage for the 
Mercury hardware platform.  Two reader interfaces provide control for two doors. 

The EP4502 communicates with the host via on-board 10Base T/100Base-TX Ethernet port.  

Two  physical  barriers  can  be  controlled  with  the  EP4502.    Each  reader  port  can  accommodate  a  read-
head  that  utilizes  Wiegand,  magnetic  stripe,  or  2-wire  RS-485  electrical  signaling  standards  and  also 
provides tri-stated LED control, and buzzer control (one wire LED mode only).  Four Form-C relay outputs 
may  be  used  for  strike  control  or  alarm  signaling.    The  relay  contacts  are  rated  at  5  A  @  30  Vdc,  dry 
contact configuration.  Eight inputs  are provided for monitoring the  door contacts, exit push buttons and 
alarm contacts.  The EP4502 requires 12 to 24 Vdc for power. 

2.  EP4502 Hardware: 

 

 

 

2.00 [50.80]

3.00 [76.20]

2.00 [50.80]

8.00 [203.20]

5.50 [139.70]

6.00 [152.40]

Ø0.156 [Ø3.962]

8 PLACES

R

E

S

E

T

2

3

4

1

S1

ON

J1

J11

3.3V

J9

J5

8V

5V

S2

IN

1

IN

2

IN

3

IN

4

IN

5

IN

6

IN

7

IN

8

K 1

K 2

K 3

K 4

1

2

3

4

5

6

7

BAT

BT1

3V

BR/CR2330

BA

S

E

 2-D

OO

R

USB HOST

ETHERNET

J12

P

AS

S

J7

1

2

V

DA

T

D0

CL

K

D1

BZR

LE

D

VO

TB

8

G

N

D

DA

T

D0

CL

K

D1

BZR

LE

D

VO

TB

9

G

N

D

TB

1

G

N

D

F

LT

G

N

D

V

IN

G

N

D

TM

P

NO

C

NC

NO

C

NC

O

U

T1

O

U

T2

C

NC

NO

C

NC

O

U

T3

O

U

T4

NO

READER 1

READER 2

TB1

0

TB1

1

+

TR+

TR

-

G

N

D

TB

2

TR+

TR

-

G

N

D

TB

3

m

ic

ro

S

D

J1

0

IN3

IN4

TB

4

IN1

IN2

TB

5

TB

6

IN5

IN6

TB

7

IN7

IN8

RS4

85

 -1

RS4

85

 -2

J2

BATTERY: BR/CR2330
REPLACE ANNUALLY

INPUT

STATUS

LEDs

OUTPUT
STATUS
LEDs

DIP SWITCHES

RESET SWITCH

STATUS

LEDs

RESET

PROCESSOR
RESET SWITCH

CHASSIS
GROUND

PROCESSOR

STATUS LED

0.25 [6.35]

S1

0.50 [12.70]

Содержание EP4502

Страница 1: ...al signaling standards and also provides tri stated LED control and buzzer control one wire LED mode only Four Form C relay outputs may be used for strike control or alarm signaling The relay contacts...

Страница 2: ...NO Normally Open Contact Input 4 IN4 C Common IN4 NC Normally Closed Contact TB6 Input 5 IN5 Out 4 NO Normally Open Contact IN5 C Common Input 6 IN6 NC Normally Closed Contact IN6 TB7 Input 7 IN7 IN7...

Страница 3: ...fault parameters after OEM code has been changed Recover from database corruption causing EP4502 board to continuously reboot If clearing the memory does not correct the initialization problem contact...

Страница 4: ...the communication channel 7 Reader Wiring Each reader port supports Wiegand magnetic stripe and 2 wire RS 485 electrical interfaces Power to the reader is selectable 12 Vdc VIN must be greater than 2...

Страница 5: ...door lock mechanisms or alarm signaling The relay contacts are rated at 5 A 30 Vdc dry contact configuration Each relay has a Common pole C a Normally Open pole NO and a Normally Closed pole NC When...

Страница 6: ...tions are available to disable SNMP Zeroconf discovery as well as the web configuration module itself Additionally data encryption can also be enabled over the host communication port 12 Status LEDs P...

Страница 7: ...f this device must comply with all local fire and electrical codes Primary Power 12 to 24 Vdc 10 500 mA maximum reader current not included Memory and Clock Backup Battery 3 Volt Lithium type BR2325 B...

Страница 8: ...ury Security assumes no responsibility for products damaged by improper handling or installation This warranty is limited to the repair or replacement of the defective unit There are no expressed warr...