Section 6 - Storage
Page 84
90-8M0053372
eng
NOVEMBER 2010
a -
Water circulating pump hose
b -
Fuel cooler to thermostat housing
a -
Check valve (if equipped)
Air‑Actuated Single‑Point Drain System
Boat in the Water
NOTE: This procedure is written for the air pump that is attached to the engine. However, any air source can be used.
1. Close the seacock (if equipped) or remove and plug the water inlet hose.
2. Remove the air pump from the engine.
3. Ensure that the lever on top of the pump is flush with the handle (horizontal).
4. Install the air pump on the actuator fitting.
5. Pull lever on air pump (vertical) to lock pump on the fitting.
a -
Actuator fitting
b -
Green indicators
c -
Manual release valve
d -
Air pump
e -
Lever (locking)
6. Pump air into the system until both green indicators extend and water drains from both sides of the engine. The port side
will begin draining before the starboard side.
a
b
6130
a
6131
8293
b
d
e
a
c
Содержание 3.0 TKS
Страница 4: ......
Страница 8: ...Page iv 90 8M0053372 eng NOVEMBER 2010 ...
Страница 26: ...Section 1 Warranty Notes Page 18 90 8M0053372 eng NOVEMBER 2010 ...
Страница 52: ...Section 4 Specifications Notes Page 44 90 8M0053372 eng NOVEMBER 2010 ...
Страница 104: ...Section 6 Storage Notes Page 96 90 8M0053372 eng NOVEMBER 2010 ...