background image

INSTALLATION

Install the PD-4 in the most convenient location for ease of cleaning, maintenance, and general operation.  Avoid
installing in locations with drafts, close proximity to grease or vapor-producing appliances, or other high ambient
heat equipment.  Recommended height from floor to bottom of toaster is 43”.  Shelf or counter top should be able
to support the toaster weight of 24 lbs.  Overhead  clearance from top of toaster should allow for easy loading and
heat dissipation.  10” minimum clearance is recommended

.

WARNING

This toaster must be plugged into the proper voltage which is specified on the data plate located on the back panel of the toaster.

Use of any other voltage or altering of plug will damage unit, void the warranty, and may cause injury.

ELECTRICAL SPECIFICATIONS

Voltage

(Volts AC)

Amperage

(Amps)

Max.

Power

(KW)

Frequency

(HZ)

Phase

Cord

(Attached)

Plug

(Attached)

120

16

1.9

50/60

1

3’

NEMA 5-20P

208

13

2.6

50/60

1

3’

NEMA 6-15P

240

11

2.6

50/60

1

3’

NEMA 6-15P

*220

10

2.2

50

1

3’

NONE

*240

11

2.6

50

1

3’

NONE

The circuit on which the receptacle is installed must be of adequate wiring size and sufficient  capacity to meet the
requirements indicated on the unit data plate and in  accordance with the National Electrical Code and local
electrical installation codes. 
I. 

The 220V  electrical information in the shaded area pertains  to European  models.  The  240V electrical
information in the shaded area pertains to United Kingdom models.

208 Volt and 240 Volt Models:

The PD-4 is equipped for electrical installation using a receptacle located in the back of  the toaster.  A specially
designed detachable cordset fits the receptacle and comes with the proper plug for the voltage requirements of
the toaster.  If you prefer, the PD-4 may be connected directly to your electrical service by an authorized service
agency or qualified electrician.

Содержание PD-4

Страница 1: ...ull control for the degree of toasting desired The solid state computer circuitry ensures consistant results every time no mater how frequently the toaster is used The information in this manual will contain part numbers and descriptions of replacement parts along with illustrations and guidelines for repairs Merco Savory Inc 1111 North Hadley Road Fort Wayne IN 46801 Service Hot Line 800 701 2992...

Страница 2: ...uence is complete the timers open the normally closed upper and lower solenoids activating the linkages opening the doors and allowing the product to drop down into the receiving tray NOTE At any time during the toasting cycle the circuit may be interrupted by pressing the reset but ton This will stop the voltage and open the release doors TABLE OF CONTENTS SEQUENCE OF OPERATIONS 2 WIRING DIAGRAM ...

Страница 3: ...WIRING DIAGRAMS ...

Страница 4: ......

Страница 5: ...toasting cycle Doors flutter PROCEDURE Check solenoids and timer Check for loose or improper wiring If all of these prove correct Replace chassis assembly pre 1982 models only Check wiring and timer Check reset button and timer Check timer heating elements and wiring Check heating elements relay timer push to toast button Check wiring Check toasting light relay timer Check wiring Check push to toa...

Страница 6: ...REMOVAL INSTALLATION AND ADJUSTMENT HEATER CARD ...

Страница 7: ......

Страница 8: ...UPPER AND LOWER CHASSIS ...

Страница 9: ...OASTER TERMINALS 6 1 VOLTS MEASURED WHILE DEPRESSING RESET BUTTON TERMINALS 5 1 VOLTS MEASURED WHILE TOASTING TERMINALS 3 2 VOLTS MEASURED WHILE DOORS OPENING TERMINALS 4 2 VOLTS MEASURED WHILE TOASTING A C VOLTS A C VOLTS t 10 A C VOLTS A C VOLTS A C VOLTS 95 52 50 8 9 8 9 100 54 53 8 9 8 9 105 57 55 8 9 8 9 110 59 57 8 9 8 9 115 62 60 8 9 8 9 120 65 62 8 9 8 9 125 69 65 8 9 8 9 190 98 95 8 9 8 9...

Страница 10: ...wer KW Frequency HZ Phase Cord Attached Plug Attached 120 16 1 9 50 60 1 3 NEMA 5 20P 208 13 2 6 50 60 1 3 NEMA 6 15P 240 11 2 6 50 60 1 3 NEMA 6 15P 220 10 2 2 50 1 3 NONE 240 11 2 6 50 1 3 NONE The circuit on which the receptacle is installed must be of adequate wiring size and sufficient capacity to meet the requirements indicated on the unit data plate and in accordance with the National Elect...

Страница 11: ......

Страница 12: ...Merco Savory Inc 1111 North Hadley Road Fort Wayne IN 46801 Service Hot Line 800 701 2992 Fax 219 436 0735 www mercosavory com ...