TIMER PERFORMANCE CHART
I
LEGEND - TIMER TERMINALS
TERMINALS #1 & #2 - INPUT VOLTAGE TO TIMER
TERMINALS #5 & #1 -- RELAY COIL (INPUT)
TERMINALS #6 & #1 - SOLENOID
TERMINALS #3 & #2 - RESET BUTTON
TERMINALS
#4 & #2 -
PUSH TO TOAST BUTTON
TYPICAL TOASTING TIMES
Minimum setting (Light) 40-50 seconds.
Maximum setting (Dark) 2 min., 10-40 seconds.
LINE
VOLTAGE
TO
TOASTER
TERMINALS
#6
&
#1 VOLTS
MEASURED
WHILE
DEPRESSING
RESET
BUTTON
TERMINALS
#5 & #1
VOLTS
MEASURED
WHILE
TOASTING
TERMINALS
#3 & #2-
VOLTS
MEASURED
WHILE
DOORS
OPENING
TERMINALS
#4 & #2
VOLTS
MEASURED
WHILE
TOASTING
A.C.
VOLTS
A.C. VOLTS
( t 10%)
A.C. VOLTS A.C. VOLTS
A.C. VOLTS
95
52
50
8-9
8-9
100
54
53
8-9
8-9
105
57
55
8-9
8-9
110
59
57
8-9
8-9
115
62
60
8-9
8-9
120
65
62
8-9
8•.9
125
69
65
8-9
8-9
190
98
95
8-9
8-9
200
103
100
8-9
8-9
210
108
105
8-9
8-9
220
113
110
8-9
8-9
230
119
115
8-9
8-9
240
124
120
8-9
8-9
250
125
124
8-9
8-9