2-2
Part Number: MER_IOM_8197455
Installation
Section 2
RATED VOLTAGES, CYCLES, PHASES, WATTAGE, AMPERAGES & POWER CORD CHART
Units with plugs are supplied with approximately 9ft cords, maximum 10ft.
Domestic Model
Voltage, Cycle, Phase
Watts
Amps
Plug
MHC22SNT1T
120V, 60H, 1Ph
660
5.5
5-15P
MHC22SNL1T
120V, 60H, 1Ph
660
5.5
5-15P
MHC24SNT2T
120V, 60H, 1Ph
1320
11.0
5-15P
MHC52SNT1T
120V, 60H, 1Ph
1920
16.0
5-20P
MHC54SNT1T
120V, 60H, 1Ph
2880
24.0
L5-30P
Weight of Equipment
Domestic Model
Weight
MHC22SNT1T
38lbs (17kg)
MHC22SNL1T
38lbs (17kg)
MHC24SNT2T
64lbs (29kg)
MHC52SNT1T
147lbs (67kg)
MHC54SNT1T
245lbs (111kg)
Clearance Requirements
DANGER
Minimum clearance requirements are the same for
noncombustible locations as for combustible locations.
The flooring under the appliance must be made of a
noncombustible material.
DANGER
Risk of fire/shock. All minimum clearances must be
maintained. Do not obstruct vents or openings.
Sides/Back
1.0” (25mm)
Dimensions
Domestic Model
Width
Depth
Height
MHC22SNT1T
20.70”
(52.58cm)
12.10”
(30.73cm)
11.50”
(29.21cm)
MHC22SNL1T
15.60”
(39.62cm)
12.10”
(30.73cm)
15.40”
(39.12cm)
MHC24SNT2T
37.50”
(95.25cm)
12.10”
(30.73cm)
11.50”
(29.21cm)
MHC52SNT1T
20.70”
(52.58cm)
22.30”
(56.64cm)
21.80”
(55.37cm)
MHC54SNT1T
32.80”
(83.31cm)
22.40”
(56.89cm)
27.50”
(69.85cm)
Electrical Service
DANGER
Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
DANGER
Copper wire suitable for at least 167°F (75°C) must be
used for power connections.
n
Warning
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.
VOLTAGE
All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for
each unit.
• A qualified electrician must determine proper wire size
dependent upon location, materials used and length
of run (minimum circuit ampacity can be used to help
select the wire size).
• The maximum allowable voltage variation is ±10% of
the rated voltage at equipment start-up (when the
electrical load is highest).
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.