background image

P 2

2

3

4

5

1

6

7

8

9

10

11

12

13

14

15

16

17

18

20

19

21

Door Panel

Back Panel

Short Panel

Short Window

Panel

AI-03LBRO1208DP-V7

Internal Panel

AI-03LBRO1208BP-V7

AI-03LBRO1208SPP-V7

AI-03LBRO1208SWP-V7

AI-03LBRO1208INPP-V7

Floor 

Roof

Front Window

Panel

Storage Door 

Panel

Side Panel

AI-03LBRO1208F-V7

AI-03LBRO1208R-V7

AI-03LBRO1208FWP-V7

AI-03LBRO1208SDP-V7

AI-03LBRO1208PP-V7 

QTY x2 

QTY x2 

Double Boarded Gable Top

Gable Top Right

Gable Top Left

AI-03LBRO1208GTDB-V7

AI-03LBRO1208GTR-V7

AI-03LBRO1208GTL-V7

Storage Gable 

Left

Storage Gable 

Right

AI-03LBRO1208SGPL-V7 AI-03LBRO1208SGPR-V7

Under Roof

Veranda

Small Floor

AI-03LBRO1208UR-V7

AI-03LBRO1208V-V8

AI-03LBRO1208SF-V7

QTY x2 

Storage Door

Slave Door

Master Door

AI-03LBRO1208MD-V7

AI-03LBRO1208SD-V7

AI-03LBRO1208SHD-V7 

QTY x2 

22

30

29

28

27

26

25

24

23

5x Floor Blocks - 28x28x400mm

Cover Trim A - 12x56x1980mm

2x Cover Trim B - 12x56x2000mm

Cover Trim C - 12x56x2011mm

Cover Trim D - 12x56x2040mm

Cover Trim E - 12x56x2070mm

2x Cover Trim F - 12x56x2080mm

2x Front Fascia - 12x134x1903mm

4x Side Fascia - 12x134x1250mm

F2828-400mm

S12134-1250mm

Fixing Kit

Door Stop

32

34

Felt

35

2x Press Lock Base- 

28x28x95mm

36

37

38

Press Lock

Handle

4x Barrel Bolt

Fixing Kit continues on P3

S12134-1903mm

S1256-1980mm

S1256-2000mm

S1256-2011mm

S1256-2040mm

S1256-2070mm

S1256-2080mm

PLY TRIANGLE

F2828-95mm

PI-07-0162

PI-07-0114

PI-07-0159

31

2x Door Trim - 16x60x1698mm

F1660-1698mm (rounded edge)

Panel Framing- 44x44x1910mm

33

F4444-1910mm

17b

Plain Door

AI-03LBRO1208PD-V7

03LBRO1208-V7

Overall Dimensions:

Width =3796mm 

Depth = 2514 mm 

Height = 2146mm

Base Dimensions: 

Width = 3688mm 

Depth = 2439mm 

Please retain product label and instructions for future reference

             

Before assembly  

please make sure you have a 

suitable base ready to erect your 

building 

 

MADE IN GREAT BRITAIN

Содержание 03LBRO1208-V7

Страница 1: ...ossible and annually to prevent the timber from deteriorating and to waterproof it This is required to maintain the anti rot guarantee Dip Treated buildings Require a preservative treatment to protect...

Страница 2: ...8 27 26 25 24 23 5x Floor Blocks 28x28x400mm Cover Trim A 12x56x1980mm 2x Cover Trim B 12x56x2000mm Cover Trim C 12x56x2011mm Cover Trim D 12x56x2040mm Cover Trim E 12x56x2070mm 2x Cover Trim F 12x56x...

Страница 3: ...4x50mm screws fix the small floor in place as shown in the diagram 4x50mm Screws Pre drill hole 50mm screw 13 Please retain product label and instructions for future reference 41 42 43 12x Butt Hinge...

Страница 4: ...the side of one Back Panel No 5 against the side of the other Back Panel No 5 with 3x50mm screws as shown in diagram Do not secure the building to the Floor until the roof is fitted 3x50mm Screws Pre...

Страница 5: ...s 21 3 4 Pre drill hole 50mm screw Step 10 Place the Door Panel No 1 onto a flat surface and fix the Front Window Panel No 2 in place as shown Make sure the panels are flush to each other 3x50mm Screw...

Страница 6: ...op and bottom of the door strips as shown in diagram Use 4x10mm screws per barrel bolt Ensure doors open and close freely 10x30mm Screws 8x10mm Screws 40 42 The Mortice Lock is Reversible 39 38 Pre dr...

Страница 7: ...l No 7 with the boarding facing outwards as shown Fix with 3x50mm screws per gable side as shown in diagram Do not secure the building to the Floor until the roof is fitted 6x50mm Screws Pre drill hol...

Страница 8: ...1 Pre drill hole 70mm screw Step 17 Lay the 2x Veranda No 15 face down side by side and fix together with 3x70mm screws through the bearers as shown in the diagram to secure the two Verandas together...

Страница 9: ...ws Pre drill hole 50mm screw Step 19b Fix the two Roof panels together using 50mm screws offset from each other as shown in the diagram Do not secure the building to the Floor until the roof is fitted...

Страница 10: ...through the panel into the floor External panels not shown Pre drill hole 50mm screw 12 Pre drill hole 30mm screw Step 21 Place the Under Roof No 12 into position making sure it is flush to the Door...

Страница 11: ...199x Felt tacks Felt Length 3910mm Ensure you overlap the felt by 100mm Felt tacks 1 2 3 35 P 11 Step 23 Fix the Facias 4x No 29 and 2x No 30 into position as shown No 29 are for the front and No 30 a...

Страница 12: ...No 33 to bottom right of door panel at the back Use 3x30mm screws 2x45mm Bolt 3x30mm Screws Pre drill hole 37 30mm screw 30mm screw Button Step 27 Attach two Turn Buttons No 43 to the Storage Door at...

Страница 13: ...2 1 3 4...

Страница 14: ...1 2 REGISTER FOR YOUR ANTI ROT GUARANTEE TODAY PLEASE SCAN HERE...

Отзывы: