Mercia Garden Products 03DTSHAX0608FGD4MW-V1 Скачать руководство пользователя страница 6

P 6

Please retain product label and instructions for future reference

             

Pre drill 

hole

50mm 

screw

IMPORTANT:

 Pre-drill before fixing screws.

Step 2

Parts Needed- No.2 QTY 1

 

 

- No.3 QTY 1

 

Place the Side panel 

(No.2)

 and the Back 

Panel 

(No.3)

 onto the floor. Fix at the corner 

using 3x50mm screws.

Do not secure the building to the floor 

until the roof has been fitted.

Position the panels so there is equal spacing 

between the floor and cladding on all sides.

The side panels should sit higher than 

then Back panels 

3x50mm Screws 

2

3

a

a

a

a

Pre drill 

hole

50mm 

screw

3

IMPORTANT:

 Pre-drill before fixing screws.

Step 3

Parts Needed- No.2 QTY 1

 

 

- No.3 QTY 1

 

Place the Side panel 

(No.2)

 and the Back 

Panel 

(No.3)

 along side the standing panels. 

Fix in an alternating pattern using 3x50mm 

screws per panel.

Do not secure the building to the floor 

until the roof has been fitted.

Position the panels so there is equal 

spacing between the floor and cladding on 

all sides. 

6x50mm Screws 

 

 

2

a

a

a

a

a

a

2ft EXTENSION PACK

Step 2a

Parts Needed- No.2 QTY 1

 

 

- No.3 QTY 1

 

 

- No.31 QTY 1

 

Place the Plain panel Extension 

(No.31)

 and 

the Back Panel 

(No.3)

 onto the floor. Fix at the 

corner using 3x50mm screws.

Place the Side panel 

(No.2)

 onto the floor and 

fix along the side in alternating pattern using 

3x50mm screws.

Do not secure the building to the floor 

until the roof has been fitted.

Position the panels so there is equal 

spacing between the floor and cladding on 
all sides.

 

The side panels should sit higher than the 

Back panels

6x50mm Screws 

Pre drill 

hole

50mm 

screw

a

Pre drill 

hole

50mm 

screw

2ft EXTENSION PACK

Step 3a

Parts Needed- No.2 QTY 1

 

 

- No.3 QTY 1

 

 

- No.31 QTY 1

 

Place  the Back Panel 

(No.3)

 and the Side panel 

(No.2)

 onto the floor. Fix in an alternating 

pattern using 3x50mm screws per panel

Place the Plain panel Extension 

(No.31) 

onto 

the floor. Fix at the corner using 3x50mm 

screws

Do not secure the building to the floor 

until the roof has been fitted.

Position the panels so there is equal spacing 

between the floor and cladding on all sides. 

The side panels should sit higher than the Back 

panels

9x50mm Screws 

 

 

10x8 Summer 

House

a

a

a

a

a

a

2

3

31

8x8 Summer 

House

a

a

a

a

a

a

2

3

31

8x8 Summer 

House

a

a

a

a

a

a

a

a

a

3

2

31

10x8 Summer 

House

a

a

a

a

a

a

a

a

a

3

2

31

Please note: The side panels are all 

interchangeable and can be positioned in

a variety of configurations. Decide which 

works best before assembly

Please note: The side panels are all 

interchangeable and can be positioned in

a variety of configurations. Decide which 

works best before assembly

Содержание 03DTSHAX0608FGD4MW-V1

Страница 1: ...d avoid placing your garden building underneath large trees to prevent the tree causing damage to the building TIMBER As with all natural materials timber can be affected during various weather condit...

Страница 2: ...Pack Required 03DTSHAX0608FGD4MW V1 QTY 1 03DTSHAX0208NWPB V1 QTY 2 10x8 Summer House Overall Dimensions Width 2494mm Depth 2457mm Height 2344mm Base Dimensions Width 2350mm Depth 2390mm Pack Required...

Страница 3: ...Frame Strip 12x40x1740mm QTY 2 S1240 1740mm 17 Door Cover Trim 12x43x940mm QTY 1 S1243 940mm 18 Fascia 12x95x1365mm QTY 4 S1295 1365mm 19 Ridge Bar 27x70x1703mm QTY 1 F2770 1703mm Corner Brace QTY 2 P...

Страница 4: ...lain Panel Extension QTY 2 AI S11SHPP600X1717 V1 32 Floor Blocks QTY 8 F2828 400mm 33 34 U Channel QTY 3 PI 07 0031 Ridge Bar 27x70x599mm QTY 1 F2770 599mm If 2ft Extension Pack has been purchased Ple...

Страница 5: ...together using 10x50mm screws through the floor bearers in an alternating pattern 10x50mm Screws 6 50mm screw 6 2ft EXTENSION PACK Step 1a Parts needed No 6 QTY 2 No 29 QTY 1 No 32 QTY 8 Place the fl...

Страница 6: ...rusing3x50mmscrews PlacetheSidepanel No 2 ontothefloorand fixalongthesideinalternatingpatternusing 3x50mmscrews Donotsecurethebuildingtothefloor untiltheroofhasbeenfitted Positionthepanelssothereisequ...

Страница 7: ...g on all sides 6x50mm Screws a a a a a a Pre drill hole 50mm screw 2ft EXTENSION PACK 10x8 SUMMER HOUSE ONLY Step 4a Parts Needed No 31 QTY 2 Place the Plain panels Extensions No 31 onto the floor Fix...

Страница 8: ...re drill hole 40mm screw 12 Step 6 Parts Needed No 12 QTY 1 Place the Door Framing No 12 onto the floor between the Front Window Panels Ensure the framing is flush to the Window Panel framing Ensure t...

Страница 9: ...20x30mmScrews 10x8SummerHouse 19 24 24 19 24 33 33 33 40mm screw Pre drill hole 5 5 Step 9 Parts needed No 5 QTY 2 For 2ft Extension Pack go to Step 9a on the next page Place the Roof Panels No 5 on...

Страница 10: ...ay out of the Roof extensions already laid on the bulindg fix the remaining roof extensions onto the builing and secure to the ridge bar using 2x60mm screws per Roof Extension It is essential that the...

Страница 11: ...om internally of the Window No 4 as shown with 1x30mm screw per block 4 Window blocks should be used per window Place the Window into the window hole in the Front and Side Window Panel and fix by scre...

Страница 12: ...key holes 4x20mm Black screws Pre drill hole 20mm screw Step 14 Parts Needed No 15 QTY 1 No 16 QTY 2 On the inside of the building fix the Door Frame Strips No 15 and No 16 to the top and sides of the...

Страница 13: ...ews Pre drill hole 20mm screw 23 28 28 Step 18 Parts Needed No 14 QTY 7 Fix the Cover trims No 14 to each corner and over the panel joins secure using 3x30mm screws per cover trim Cover trims may need...

Страница 14: ...rews IMPORTANT Pre drill before fixing screws HANDLE WITH CARE 1 2 3 4 Step 20 Parts Needed No 27 QTY 1 Cut the Felt No 27 into 3 sheets of 2510mm and lay onto the roof in the order shown in the diagr...

Страница 15: ...score around protective cover on glazing and carefuly peel covering back P15 Please retain product label and instructions for future reference Step 20b Parts Needed No 35 QTY 4 Place the Veranda No 35...

Страница 16: ...he Window framing using 6x20mm screws as shown in the diagram Further secure the crosses by screwing 1x10mm screw at each meeting point as shown in the diagram 24x20mm screws 8x10mm screws Pre drill h...

Страница 17: ...gh the roof fram ing Fix the Diamond Finials No 26 to the Fascias using 2x30mm screws per finial 10x30mm Screws 18 26 18 18 18 26 It is ESSENTIAL that you apply wood treatment immediately after the bu...

Страница 18: ...2 1 3 4...

Страница 19: ...1 2...