Installation  Instructions

 

4.1

 

Choose Your Mounting Location

 

A good mounting location is important to getting the best performance out of your MR76-HW 
access point.  Keep the following in mind:

 

 

1.

 

The device should have unobstructed line of sight to most coverage areas. For example, if 
installing   in an office filled with workspaces divided by mid-height cubicle walls, installing on 
the ceiling or high  on a wall would be ideal.

 

 

2.

 

Power over Ethernet supports a maximum cable length of 300 ft (100 m).

 

 

3.

 

If being used in a mesh deployment, the MR76-HW should have line of sight to at least two 
other Meraki devices.  For  more  detailed  instructions  regarding  access  point  location  selection, 
reference  the  Meraki  Network  Design  Guide  (

meraki.com/library/product

).

 

 

4.2

 

Install the MR76-HW

 

For most  mounting scenarios,  the MR76-HW  mount plate  provides a  quick,  simple, and  flexible means 
of mounting  your device. The installation should be done in two steps. First, install the mount plate to 
your selected location.  Then,  attach  the  MR76-HW  to  the  mount  plate. 
 

!!! This equipment is only 

suitable for mounting at heights ≤ 2 m !!!

 

 

4.2.1

 

Attach the Mount Plate

 

The MR76-HW mount plate can be used to install your access point in a wide range of scenarios: wall 
or solid  ceiling, below a drop ceiling, on various electrical junction boxes, or above a drop ceiling (in 
the plenum).

 

The mount plate contains a variety of hole patterns that are customized for each installation scenario. 
The  mounting template (included inbox with mount plate) should be used to drill holes for wall mounts 
and also to identify the correct hole patterns in the mount plate that should be used for each type of 
mount.

 

 

The following images also show the hole patterns that should be used for each type of mount:

 

Содержание MR76-HW

Страница 1: ...Meraki MR76 HW Hardware Installation Guide...

Страница 2: ...rest of improving internal design operational function and or reliability Cisco Systems reserves the right to make changes to the products described in this document without notice Cisco Systems does...

Страница 3: ...n 10 4 Installation Instructions 11 4 1 Choose Your Mounting Location 11 4 2 Install the MR76 HW 11 4 2 1Attach the Mount Plate 11 4 2 1 1 Wall or Solid Ceiling Mount Using Mount Plate 13 4 2 1 2 Drop...

Страница 4: ...nd Related Publications The MR76 HW Hardware Installation Guide describes the installation procedure for the MR76 HW Outdoor access point Additional reference documents are available online at www mer...

Страница 5: ...R76 HW package contains the following MR76 HW access point Mounting plate Drop ceiling mounting kit Wall screws Security screws Mounting Template 2 2 Understanding the MR76 HW MR76 HW Operation Temper...

Страница 6: ...6 Access point mounting posts 2x Various mounting holes...

Страница 7: ...ucture using a standard Kensington lock 2 4 Ethernet Ports The MR76 HW features an Ethernet RJ45 port that accepts 802 3at power labeled PoE This port should be used for uplink to your WAN connection...

Страница 8: ...Go to the map floor plan view and place each AP on the map by clicking and dragging it to the location where you plan to mount it 3 2 Check and Upgrade Firmware To ensure your MR76 HW performs optima...

Страница 9: ...switch plug an Ethernet cable into the MR76 HW s Ethernet jack and the other end into a PoE switch Then connect the client machine over Ethernet cable to the PoE switch If using a Meraki PoE Injector...

Страница 10: ...lation Phillips screwdrive r Hammer Drill with 1 4 6 3mm bits 3 6 Collect Additional Hardware for Installation 802 3at PoE power source either PoE switch or Meraki 802 3at PoE Injector AC Adapter Netw...

Страница 11: ...10 location...

Страница 12: ...HW For most mounting scenarios the MR76 HW mount plate provides a quick simple and flexible means of mounting your device The installation should be done in two steps First install the mount plate to...

Страница 13: ...ncluded screws attach the mount plate to your mounting wall or ceiling It is recommended that the MR76 HW be mounted to a wall or solid ceiling using the mount plate for physical security reasons If m...

Страница 14: ...st 9 16 15 16 or 1 T rails The kit contains Dropped ceiling mounting clips with set screws 6 32x4 mm screws 6 32x7 mm screws Only used for recessed rail mount uncommon 2 rubber spacers Only used for r...

Страница 15: ...14...

Страница 16: ...ing the dashed lines on the mount plate template as a guide set the proper spacing of the T rail clips on the T rail 3 Tighten the set screws on the T rail clips to secure the clips using a 5 64 2 mm...

Страница 17: ...16 4 Attach the mount plate to the T rail clips using the mount plate holes marked with a T FlushT rail Ceiling tiles T rail flush with tiles T rail recessed from tiles...

Страница 18: ...tlet boxes mounting screws are not included Using appropriate mounting hardware for your specific type of junction box attach the mount 4 2 2 Power the MR76 HW If mounting to an electrical junction bo...

Страница 19: ...into the Eth0 port on the MR76 HW 4 2 2 2 Powering the M410 HW with the Meraki 802 3at Power over Ethernet Injector sold separately 1 Plug the power cord into the PoE Injector and the other end into...

Страница 20: ...Ethernet Switch Route Ethernet cable from a port on an active 802 3at PoE switch to the Eth0 port in the bay of the MR76 HW 4 2 3 Mount the MR76 HW The MR76 HW is Gigabit Ethernet capable To maximize...

Страница 21: ...ceiling or electrical junction box mount where you have already installed the mount plate Insert the top latch on the mount plate into the top mount plate attachment slots on the back of the device Ro...

Страница 22: ...21 4 2 3 3 Desk or Shelf Mount The MR76 HW can be placed on a desk or shelf resting on the non scratch rubber feet The mount plate is not necessary for a desk or shelf mounting...

Страница 23: ...Torx and Philips head security screws are included choose one and or Kensington lock If the mount plate was not used the MR76 HW can still be secured using a Kensington lock 4 3 1 Security Screw Inst...

Страница 24: ...ed operation FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed t...

Страница 25: ...pment should be installed and operated with minimum distance 26 cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or tran...

Страница 26: ...nement This radio transmitter IC 6961A 600100010 has been approved by Innovation Science and Economic Development Canada to operate with the antenna types listed below with the maximum permissible gai...

Страница 27: ...nterdits pour l exploitation de l metteur i the device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite sy...

Страница 28: ...t to WISPA database with TDWR locations d When within 35 km distance of a TDWR the center frequency of the WLAN must be separated from the TDWR center frequency by 30 MHz a If the radar is operating f...

Страница 29: ...s and band usage according to FCC rules are implemented through the SDR 3 Installation location The product shall be installed at a location where the radiating antenna can be kept 36cm from nearby pe...

Страница 30: ...eglementaires concernant l exposition aux radiofrequences ce produit doit etre installe de facon a respecter une distance de 36 cm entre l antenne emettrice et les personnes 3 Antenn externe Utiliser...

Отзывы: