9 |
P a g e
TECHNICAL SPECIFICATIONS FOR ML47 LINEAR ZC DECORATIVE FIREPLACE
MODEL ML47
High Fire - Adjustable to -
Low Fire
BTUH. (MODEL ML47) NAT. GAS 41,000 25,000
BTUH. (MODEL ML47) LP GAS
41,000 24,000
NOTE: LPG CONVERSION KIT, #HA-90-00110 MUST BE PURCHASED SEPARATELY TO CONVERT TO BURN LPG
IN THIS FIREPLACE.
MAIN ORIFICE [0-
2000ft (610 m)]: 1/8” NG –: #49 LP
[2000-4500ft (610-1370 m)]: #31 NG - #50 L.P.
OVERALL EFFICIENCY: [P.4: 71.3% NG, 70% LPG]
CO-AXIAL DIRECT VENT FLUE:
5" INNER, 8" OUTER, RIGID
TOTAL WEIGHT:
325 POUNDS
SAFETY:
AGA/CECERTIFIED IPI AUTO ELECTRONIC IGNITION SYSTEM
ACTIVATED WITH REMOTE CONTROL.
APPLIANCE CERTIFICATION AND TESTING AGENCY
INTERTEK TESTING SERVICES, ICBO#AA647-4
Certified under ANSI Z21.88 (2014)
CSA 2.23 (2014
) “Vented Gas Fireplace " not for use with solid fuel. Approved for
bedroom installations and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recrea-
tional vehicles."
GAS REQUIREMENTS
SUPPLY PRESSURE: GAS INLET: 1/2" N.P.T.
NAT. GAS:
7" W.C.
(5" W.C. MIIN., 11" W.C. MAX.)
L.P. GAS:
11.0" W.C.
(12" W.C. MIN., 13" W.C. MAX.)
ELECTRICAL REQUIREMENTS
115 VOLT, LESS THAN 1.5 amps (6V DC BACKUP POWER SUPPLY)
APPROVED VENT SYSTEMS
DURAVENT, SELKIRK, AMERIVENT, SECURITY, BDM
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR
0in. (0mm)
GLASS EDGE TO ADJACENT SIDEWALL 16in. (406 mm)
UNIT TO ENCLOSURE SIDEWALL
1/2in. (13mm)
VENT PIPE TOP TO COMBUSTIBLES
3in. (76mm)
UNIT TO ENCLOSURE BACK WALL
1/2in. (13mm)
VENT PIPE SIDES TO COMBUSTIBLES
1in. (25mm)
UNIT BOTTOM TO ENCLOSURE CEILING 44-3/16in. (1122 mm)
VENT PIPE BOTTOM TO COMBUSTIBLES 1in. (25mm)
UNIT BOTTOM TO ROOM CEILING
60 in. (1524 mm)
8” MANTLE ABOVE DISCHARGE AIR OPENING 12 in. (304 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
WIDTH = 54-1/4
” (138 cm)
HEIGHT = 39
” (99.6 cm)
DEPTH = 19-1/2
” (49.5 cm)
THIS FIREPLACE INCLUDES A SEALED COMBUSTION SYSTEM, NEO-CERAM GLASS, ELECTRONIC IGNITION SYSTEM, AGA CERTIFIED
SAFETY SYSTEM, DUAL ACCENT LIGHTS and REMOTE CONTROL.
OPTIONS: BLACK, VINTAGE IRON, SWEDISH NICKEL, ANTIQUE GOLD, ANTIQUE COPPER GRACE, TRADITIONS AND WILLOW BROOK TRIM
KITS. Burner Media Options include Driftwood, Twig Set and many colored and clear glass bead burner media, Natural Rocks Kit.
WARNING: Do not operate this appliance with the
glass removed, cracked or broken. A licensed or
qualified person should do replacement of glass.
Derating at altitudes above 2000 feet:
Installation of this ap-
pliance at altitudes above 2000 feet requires the gas input to be
derated by reducing the main burner orifice size. For NG and
LPG applications, the main burner orifice size for altitudes
above 2000 feet shall be 1/8” and #49, respectively. LPG gas
input rate for installation above 2000 feet shall be 40,000
Btu/Hr.