20 |
P a g e
Final Finishing Material mounted behind the Grace Front, using the Inner Guides
:
If the Final Finishing Material is mounted behind the Grace Front and you wish the front visible faces of the Grace Front
and the Traditions or Willowbrook to be close to each other, you have one option:
1.
Remove the Glass Safety Screen that is integrated on the back surface of the Grace Front. Install a Glass
Safety Screen on the back surface of the Traditions or Willowbrook Front. Mount the Grace Front inward as
far back as allowed by the Final Finish Material thickness. Mount the Traditions or Willowbrook Front at the
desired depth relative to the Grace Front. Note that the Traditions or Willowbrook Front’s visible face can be
made flush with the
Grace Front’s visible sur-
face if the Final Finishing
Material is less than ¾” and the Adjustable Framing Brackets are employed properly.
Final Finishing Material mounted outside the Grace Front using the Outer Guides
:
If the Final Finishing Material is mounted outside the Grace Front by using the Outer Guides, the Traditions or
Willowbrook Front’s front visible face must remain at least a ¼” behind the visible front face of the Grace Front and the
Glass Safety Barrier Screen installed on the Grace must remain intact. You may remove the Glass Safety Barrier Screen
installed on the Traditions or Willowbrook Front, in this case.
NON-COMBUSTIBLE FINISHING MATERIALS REQUIREMENTS
WARNING:
The cross hatched areas labeled as “NONCOMBUSTIBLE ZONE” must be covered with noncombustible fin-
ishing materials that is 1-inch thick, minimum. DO NOT ALLOW COMBUSTIBLE MATERIALS TO ENCROACH IN THIS
AREA!
Figure 5:
NON COMBUSTIBLE ZONE [ALL HATCHED AREAS]