85-03-01109
FV42
Page
21
Rough Framing Dimensions
The rough framing dimensions given are the
minimum allowed framing dimensions. Be sure
when planning the framing of the unit that
adequate space to hook up the gas and electrical
on the left side of the unit.
After the fireplace is in place the front of the unit
can be framed into the final width of 48”. This will
allow finishing material to be installed around the
unit.
SPECIAL FRAMING NOTE
:
If the fireplace is to be recessed in a cavity deeper than 20”, all framing and finishing materials protruding past the front face of
this fireplace must be of the NON-COMBUSTIBLE variety.
Minimum Required Dimensions
DESCRIPTION
DIMENSION
(INCHES)
A
ENCLOSURE FRAMING WIDTH
55”
B
FINISHED FRAMING WIDTH
48”
C
FRAMING HEIGHT
41
D
FRAMING DEPTH
20”
E
FINISH MATERIAL THICKNESS
1”
F
UNIT BASE TO ROOM CEILING
72”
G
TO SIDE WALL
16”
H
FLOOR TO 8” MANTEL
48-1/2”
Figure 3-16 FRAMING DIMENSIONS