FV42 Fireplace Ratings Information
This Mendota Fireplace can be installed directly on top of a metal, masonry or wood structural surface.
ELECTRICAL REQUIREMENTS
: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC) REQUIRED
GAS SUPPLY PRESSURE
:
NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
LP GAS CONVERSION KIT
: This Fireplace comes configured for use with Natural Gas. To convert the Fireplace for use with LP
Gas, install: LP GAS CONVERSION KIT # HA-110-00084.
GAS INPUT RATES
High Fire
Low Fire
BTUH .......................... NAT. GAS
44,000
14,100
BTUH .......................... L.P. GAS
44,000
18,600
ORIFICE SIZES
…………
[0-2000ft (610 m)]: REAR BURNER: #38 NG [#54 L.P.] – FRONT BURNER: #44 NG [#54 LP]
[2000-4500ft (610-1370 m)]: REAR BURNER: #38 NG [#54 L.P.] – FRONT BURNER: #44 NG [#54 LP]
P.4 FIREPLACE EFFICIENCY
..........75%
FLUE VENTING
............COAXIAL RIGID- 5” DIAMETER EXHAUST & 8” DIAMETER AIR INLET AND APPROVED VENT CAPS
All UL Listed Coaxial Rigid 5”X8” Vent pipe components and vent caps are approved for use. Do not mix components of
different brands or series. Always use the same brand and series components throughout the entire vent system.
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR
0in. (0mm)
INNER GUIDE EDGE TO ADJACENT SIDEWALL 16in. (406 mm)
UNIT TO ENCLOSURE SIDEWALL
1/2in. (13mm)
VENT PIPE TOP TO COMBUSTIBLES
3in. (76mm)
UNIT TO ENCLOSURE BACK WALL
1/2in. (13mm)
VENT PIPE SIDES TO COMBUSTIBLES
1in. (25mm)
UNIT BOTTOM TO ENCLOSURE CEILING 54 in. (137 cm)
VENT PIPE BOTTOM TO COMBUSTIBLES 1in. (25mm)
UNIT BOTTOM TO ROOM CEILING
72 in. (1829 mm)
DISTANCE TO 8” MANTLE ABOVE TOP CONVECTION AIR DISCHARGE OPENING
22 in. (559 mm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS
WIDTH = 55” (127cm)
HEIGHT = 41” (104cm)
DEPTH = 20” (51cm)
NET WEIGHT
................300 lbs. (Team Lift recommended)
BARRIER SCREEN
: A barrier screen that has been certified for use with this Fireplace must be installed on the Fireplace when it
is in use. The barrier screen will prevent accidental contact with the glass door face, which could result in a severe burn.
SAFETY
: AGA certified, electronic ignition IPI system activated with thermostatic remote control.
CERTIFIED TO
: ANSI Z21.88-2017 CSA 2.33-2017
This Mendota Gas Fireplace has been tested and certified by:
Intertek Testing Services, 8431 Murphy Drive, Middleton, WI 53562\
ICBO#AA647-4
Содержание FV42
Страница 15: ...85 03 01109 FV42 Page 15 Figure 3 11 Figure 3 10...
Страница 87: ...85 03 01109 FV42 Page 87 Gas Train Assembly Parts Figure 6 5 Gas Train Assembly Parts...
Страница 88: ...85 03 01109 FV42 Page 88 Burners Figure 6 6 Burners...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...