ATTENTION!
The transmitter and receiver are RADIO FREQUENCY DEVICES. Placing the receiver in or near metal may
severely reduce the signal range.
Turn off the main gas supply of the appliance during installation or maintenance of the receiver.
Place the receiver’s 3-position slider switch in the “off” position during installation or maintenance.
Turn “off” main gas supply to the appliance prior to removing or reinserting the batteries in the receiver.
During appliance installation/maintenance or in case of remote control malfunction, turn off electrical supply to
this appliance and remove the batteries from the wall receiver battery compartment. Contact technical service.
ATTENTION!
The transmitter and receiver are RADIO FREQUENCY DEVICES.
Turn off the main gas supply of the appliance during installation or maintenance of the receiver.
Toggle the Master Switch to OFF during installation or maintenance.
During appliance installation/maintenance or in case of remote control malfunction, turn off electrical sup-
ply to this appliance and disconnect the Backup batteries from the wall DC connector. Contact technical
service.
IPI/STANDING PILOT SYSTEM INFORMATION
Intermittent Pilot Light and Standing Pilot Light Features
This gas fireplace is equipped with an electronic ignition System that first lights a pilot light then uses the pilot light to ignite
the main burners. The pilot light can be set in the CPI (Standing Pilot) mode to allow the pilot light to remain on indefinitely
by setting the Remote Transmitter to CPI mode. If the remote transmitter is set to the IPI (Intermittent Pilot) mode, the
pilot light will only light and remain ON while the main fireplace burners are operating.
IPI Mode: This mode turns the pilot light “OFF” when the fireplace is not functioning and only lights the pilot light automati-
cally when a call for heat is made by the remote con-
trol.
(CPI) Standing Pilot Mode: If set to CPI Mode, the
pilot light will ignite and remain ON at all times.
Setting to IPI versus CPI mode:
With the remote transmitter OFF, press the
MODE button. You will see either “CPI” or
“IPI” displayed on the transmitter screen.
Press the
UP arrow button to set “CPI” mode
and press the DOWN arrow butto
n to set “IPI”
mode. One set to the desired setting, press On/Off button to activate the fireplace.
NOTE
:
Mendota Fireplaces recommends that the (CPI) Standing Pilot Mode be used during the winter months
when the average daily high temperature falls below 50
o
F
. This will keep the fireplace chimney heated for proper up-
draft during burner ignition and it will also eliminate excessive condensation of exhaust vapors on the door glass. Further,
leaving the fireplace in the Standing Pilot Mode will keep the fireplace body warm and eliminate cold drafts and heat loss to
the cold air that is trapped inside the firebox.
REMOTE CONTROL
IGNITION MODULE/ RECEIVER
Supply voltage
4.5V (three 1.5V AAA batteries)
6.0V (four 1.5V AA batteries)
Ambient temperature ratings
32
– 122
o
F (0
– 50
o
C)
32
– 140
o
F (0
– 60
o
C)
Radio Frequency
315 MHz
315 MHz