background image

50 | 

P a g e

 

 

  

MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY  

MENDOTA FV41-M DIRECT VENT FIREPLACE  

 

Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Lifetime Protection and Li-
mited Warranty to the original purchaser of a Mendota FV41-M Fireplace, which is limited and used under normal home conditions. 
 

STANDARD WARRANTY: 

 
JOHNSON GAS APPLIANCE CO., MENDOTA DIVISION, WARRANTS THAT YOUR NEW MENDOTA FIREPLACE IS FREE FROM 
MANUFACTURING AND MATERIAL DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF INSTALLATION, SUBJECT TO THE 
FOLLOWING CONDITIONS AND LIMITATIONS: 
 

EXTENDED LIFETIME WARRANTY: 

 
THE HEAT EXCHANGER, BURNER TUBE COMBUSTION CHAMBER AND OUTER SHIELD OF THE MENDOTA FV41-M FIREPLACE ARE 
WARRANTED FOR THE LIFETIME OF THE ORIGINAL OWNER, SUBJECT TO PROOF OF PURCHASE AND THE FOLLOWING CONDITIONS 
AND LIMITATIONS: 
 
1)

 

This new Mendota Fireplace must be installed & serviced by a competent, authorized service contractor.  It must be installed and operated at all times 
in accordance with the installation and operating instructions furnished with the Fireplace.  All adjustments to logs, coals or burner must be made by 
an authorized Mendota person.   Any alteration, willful abuse, accident or misuse of the product shall nullify this warranty.  This warranty does not 
cover glass or log breakage.   

  

This limited warranty does not cover the cost of service calls, the cost of labor to remove or install parts covered by this limited warranty, freight or 
other transportation expenses, which may be incurred in connection with obtaining performances under this limited warranty.  The remedy for dam-
ages as the result of any defects in this product which have been warranted herein is limited to replacement parts and does not include any incidental, 
indirect or consequential damages or expenses sustained in connection with the product, including damages to property, except as provided by law.  

 
2) 

This warranty is non-transferable and is made to the original retail purchaser, provided the purchase was made through an authorized Mendota dealer.  

Mendota is not responsible for any damage to or malfunction of the Fireplace unless caused by a defect in material or workmanship from normal 
home use.  Damage caused by abuse, improper installation, improper servicing, and installation by unqualified personnel or breech of conditions of 
this limited warranty will excuse Mendota from performance of any part of this limited warranty.  Mendota has the right to investigate and inspect the 
exact, original Fireplace and entire installation (without any alterations or tampering) in the event a claim is made to determine whether the claimed 
damage or malfunction was caused by abuse, improper installation or other cause outside this warranty.  Mendota is not responsible for  any repairs 
or material purchases that have not received prior written approval from Mendota. 

 

 

NOTE:  Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty.  Major warping of parts can be caused by 

over-firing of your Mendota Fireplace.  Over-firing above rated nameplate specification is as contrary to the manufacturer's instructions and may 
void this warranty. 
This warranty may not be extended by our representatives or any third party in any manner. The company neither assumes, nor authorizes any  third 
party to assume, on its behalf, any other liabilities with respect to the sale of this Mendota product. 

 
3) 

Mendota may at its discretion, fully discharge all obligations of this warranty by refunding the wholesale price of the defective part(s). 

 

 

4) 

All other warranties - expressed or implied - with respect to the product, its components and accessories, or any obligation/liabilities on the part of the 
company are hereby expressly excluded.  Products made by other manufacturers, sold with the Fireplace or thereafter, are not covered by this limited 
warranty.  The use of unauthorized components will make this warranty null and void. 

 
This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division within thirty (30) days of the 
date of purchase.  Such registration or the failure to register shall not be deemed to create any obligation or liability by the manufacturer and this warranty 
with its conditions and limitations shall be the only procedure for obtaining any rights against the manufacturer and expresses the sole obligation and re-
sponsibilities of the manufacturer which are offered to the original purchaser and accepted upon purchase of the appliance. 
 
Mendota Division, reserves the right to make changes at any time without notice, in design, material, specifications, prices and the right to discontinue styles 
and products. 
Some states do not allow the exclusion of limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the 
above limitation or exclusion may not apply to you.  This warranty gives you specific legal rights and you may also have other rights which vary from state 
to state

 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание FV41-M

Страница 1: ...ation and service must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service...

Страница 2: ...de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions caref...

Страница 3: ...rri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette mesure emp chera les tout petits les jeunes en fants et t...

Страница 4: ...UIREMENTS 19 GENERAL INSTALLATION INSTRUCTIONS 20 GENERAL FLUE VENTING INSTRUCTIONS 21 EXTERIOR VENT LOCATIONS AND RESTRICTIONS 22 FLUE VENTING COMPONENTS IDENTIFICATION 23 FV41 M MASTER FLUE VENTING...

Страница 5: ...Building Code 3 A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a min imum height of eight 8 feet above grade directly in line with the exhaust...

Страница 6: ...LET CONTROLS HARNESSES EXIT GAS SUPPLY INLET 1 2 MNPT GAS TRAIN IGNITION SYSTEM RH BLOWER INSPECTION COVER LH FRAMING ATTACH BRACKETS LH LIFT HANDLE RH FRAMING ATTACH BRACKETS RH BLOWER INSPECTION COV...

Страница 7: ...LES 1in 25mm UNIT BOTTOM TO ENCLOSURE CEILING 48 1 2in 123 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINI...

Страница 8: ...onal service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control com partments burners and circulating...

Страница 9: ...TEL 48 ADJACENT WALLS A wall perpendicular to and in front of this fireplace s glass door surface must be at least 16 inches from the side edges of the facing guide A wall at 45 to the glass surface a...

Страница 10: ...ace Face the combustible mantel may pro trude outward at a Distance up From Floor Level of this Fireplace If you prefer to take measurements from the Top of the Convection Air Opening note that the To...

Страница 11: ...11 P a g e CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES Figure 2 Clearances to Combustibles 0 CLEARANCE FROM TOP STANDOFFS 1 2 CLEARANCE FROM BACK 1 2 CLEARANCE FROM SIDES...

Страница 12: ...surfaces extending full width and depth of this fireplace An R 1 Rated Hearth Protection Pad 1 1 2 Thick Maximum is required unless this fireplace is elevated For every 1 this fireplace is elevated y...

Страница 13: ...ST be adhered to Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems The chase should not break the outside building envelope in any manne...

Страница 14: ...not needed or may be permanently attached using 1 8 rivets that are supplied with this fireplace Inner Guide Identify the Inner Finishing Guides Top Left and Right These guides should be used as a gu...

Страница 15: ...rface Install 1 2 thick drywall on framing members so that its outer surface is flush with the front face of this fireplace Attach Marble or Granite slabs to face of unit and to drywall surface using...

Страница 16: ...floor level and the ceiling All hearth pads must be non combustible metal brick stone or mineral fiberboard Do not use any combustible material to protect the floor in front of this fireplace For the...

Страница 17: ...of the hearth protector may be reduced by 2 inches If fireplace is raised off the floor 6 or more no hearth protector is required HEATING PERFORMANCE With its high heat output this Mendota Fireplace w...

Страница 18: ...ny pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 kPa A proper gas line diameter must be selected to run from the supply regulator to the Firepla...

Страница 19: ...is not sufficient to add the Gas Fireplace an additional inches to inches regulator must be installed for the Fireplace EXCEPTION Some codes allow 2 PSI 1 4KPA supplies to enter the residence in whic...

Страница 20: ...ements and locations are being followed 3 This Fireplace is designed for installation into rough framing NOTE FRAMING MATERIAL ABOVE FIREPLACE MUST MAINTAIN CORRECT CLEARANCE TO FIREPLACE AND VENT PIP...

Страница 21: ...its own separate vent system Common vent systems are prohibited To assure proper venting performance of this high performance Mendota Direct Vent Fireplace it is critical that all brands of vent pipe...

Страница 22: ...K Clearance to a mechanical air supply inlet 6 feet 1 8 m minimum E Clearance to unventilated soffit 24 min 60 cm min L Clearance above paved side walk or a paved driveway located on public property 7...

Страница 23: ...EM DESCRIPTION 1 6 or 7 PIPE DuraVent 6 Amerivent 7 2 12 VENT STACK 3 24 VENT STACK 4 36 VENT STACK 5 48 VENT STACK 6 90 GALVANIZED ELBOW 45 GALVANIZED ELBOW 7 ADJUSTABLE WALL THIMBLE 8 ATTIC INSULATI...

Страница 24: ...feet maximum hori zontal run allowed with a 4 feet starter section If the starter vertical section is less than 4 feet use the chart and reduce 3 feet for every 90 0 elbow in stalled after the first 9...

Страница 25: ...systems that provide a starting vertical section less than 4 feet the following rules apply a You must use the Master Flue Venting Requirements Chart See Zone A below the 4 vertical run line b A sing...

Страница 26: ...L TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS VERTICAL TERMINATION THREE HORIZONTAL DISCHARGE 90 ELBOWS APPROVED w RESTRICTIONS STRAIGHT UP VERTICA...

Страница 27: ...enetrate the exterior wall 3 Cut and frame a 10 3 4 wide x 10 3 4 high opening in the wall The hole must be positioned so the vent system will run level or have a rise per foot of run AND be perpendic...

Страница 28: ...will pass through any ceilings and will penetrate the outside wall Since vent pipe sections overlap we suggest pre assembling and measuring the total vent pipe run so you can more accurately locate t...

Страница 29: ...29 P a g e Figure 19 Figure 20 APPROVED...

Страница 30: ...nts DuraVent only are sealed and are leak proof Maintain 1 airspace clearances to combustibles 2 above horizontal runs Cut a 10 x 10 opening in the roof centered in the small drilled hole placed in th...

Страница 31: ...31 P a g e Figure 21 1 2 3 4 5 13 15 9 10 11 12 50 FEET MAX...

Страница 32: ...fireplace and its venting system Through this effort Mendota has been able to certify the use of Four 90 0 elbows The use of Four 90 0 elbows must meet some minimum prerequisites Prerequisite 1 The v...

Страница 33: ...ree bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center tabs in slots left to right 2 Center Glass Frame over Firebox left to right 3 After...

Страница 34: ...leaks and gas pressures prior to installing facing materials Install fresh batteries in Wall Receiver and remote transmitter Follow Initializing the Sys tem for the first time instructions to synchro...

Страница 35: ...i cations start with air shutter open to 3 8 After burner has been properly installed and operated for 20 minutes small additional adjustments to the air shutter may be ne cessary for final flame appe...

Страница 36: ...ss should be cleaned periodically Exterior glass surface may be cleaned with cleaner as desired To clean interior surface of glass use soap and water CAUTION Do not use oven cleaner to clean glass Cle...

Страница 37: ...eplace if necessary D Periodically check to verify that the vent system and vent cap are open and free of blockage E Before re installing glass have qualified service person check the operation of the...

Страница 38: ...Remove Screws and lift out Burner Airbox Remove 8 screws and remove left side blower mount plate Main Orifice Pilot Hood Valve Pressure Regulator This conversion kit shall be installed by a qualified...

Страница 39: ...wn 5 Remove the Burner Locate and Identify the Burner Orifice Spud The Orifice Spuds can be removed and installed using a deep well socket and ratchet WARNING Make certain to Secure the Brass fit ting...

Страница 40: ...or failure to use only parts specifically ap proved with this appliance may result in property damage or personal injury AVERTISSEMENT Risque de dommages ou de blessures si les pi ces ne sont pas inst...

Страница 41: ...or gas leaks with soap and water solution at all plumbing joints prior to placing this appliance into operation It is recom mended that all gas plumbing joints factory installed and field installed ar...

Страница 42: ...u are derating this appliance at a high altitude also attach the High Altitude Deration Label supplied in the Owner s Manual Packet to this same surface Prior to attaching the labels fill in all the i...

Страница 43: ...Flex CF Coupler 3 1 05 04 00050 SIT Pilot Assembly 4 2 65 14 00038 ORIFICE 38 5 1 05 02 00344 885 PROFLAME SIT VALVE 6 1 65 07 00753 Elbow 90 Deg 3 8 Flared Tube X 3 8 NPT Male Brass 7 1 65 07 00012 B...

Страница 44: ...an Electrical Code Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and danger ous operation and Verify proper operation after servicing Attentio...

Страница 45: ...ts individual components are available through Johnson Gas Appliance Company Contact your dealer for more de tailed ordering information GLASS FRAME ASSEMBLY HA 78 00103 REPLACEMENT PARTS LIST ITEM PA...

Страница 46: ...be found on the rating plate which is located inside the right side controls access door When contacting your dealer for any cleaning service or warranty service always provide the Model Number Seria...

Страница 47: ...runs 1000 sealant must be used on inner joints at adjustable pipe sections CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per M...

Страница 48: ...48 P a g e NOTES...

Страница 49: ...49 P a g e TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Страница 50: ...formance of any part of this limited warranty Mendota has the right to investigate and inspect the exact original Fireplace and entire installation without any alterations or tampering in the event a...

Страница 51: ...51 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com...

Отзывы: