IMPORTANT VENTING CONFIGURATION NOTES 

See Figure 14 [MASTER FLUE VENTING REQUIREMENTS CHART]. 

HIGH ALTITUDE INSTALLATION INFORMATION

: Prior to installing at altitudes higher than 7500, please contact the 

Mendota technical service department for specific venting requirements and venting restrictions. 

MAXIMUM HORIZONTAL RUN 

A.  Maximum Horizontal Run allowed is 20 feet if a vertical starter section that is between 4 feet to 30 feet is con-

nected directly to this fireplace’s flue starter collar and no more than three (3) 90 degree elbows are used.  

B.  Maximum Horizontal Run allowed is 

18” if a 90-degree elbow is connected directly to this fireplace’s flue starter 

collar. 

MAXIMUM VENT SYSTEM LENGTH 

A.  Combined total length of all straight pipe sections in the vent system shall be less than 50 feet. 
B.  Combined total length of all straight pipe sections in the vent system shall be less than 50 feet when using three 

(3) 90-degree elbows or equivalent and terminating the vent system horizontally. 

C.  Combined total length of all straight pipe sections in the vent system shall be less than 50 feet when using four (4) 

90-degree elbows or equivalent and terminating vertically. 

HOW TO CALCULATE THE VENT SYSTEM LENGTHS 

For calculation purposes and usage of charts in this manual, simply add the lengths of all individual straight pipe sections. 
For example: if you use two 2-foot lengths and one 4-foot length, the total vent system length will be 2+2+4 = 8 feet. 

USING 90

0

 ELBOWS 

IN ZONE “B” 

The FV41-M Fireplace by MENDOTA allows maximum flexibility in the use of 90

o

 elbows in the vent system.  The length 

o

f the first straight vertical section directly connected to the fireplace’s starter collar determines the maximum horizontal 

run and the number of 90

0

 elbows allowed for this fireplace. 

For vent systems that provide a starting vertical section that is 4 feet or longer, you may connect up to 20 feet of horizon-
tal pipe and up to three (3) 90

0

 elbows within the 20 feet run in any configuration and terminate the vent horizontally.  No 

reduction in horizontal run is required for the elbows used as long as the 4 feet long vertical starter section is connected 
directly to this fireplace’s starter collar. 

USING 90

0

 

ELBBOWS IN ZONE “A”. 

For vent systems that provide a starting vertical section less than 4 feet, the following rules apply: 
a. You must use the Master Flue Venting Requirements Chart. 

See Zone “A” below the 4’ vertical run line. 

b. A single 90

º

 vertical-to-horizontal elbow is already calculated into the allowable maximum 20' horizontal run. The Vent-

ing Requirements Chart (

Figure 14

) assumes that for all horizontal runs calculated, one 90

0

 elbow is used within the vent-

ing system. 

Each additional 90

º

 elbow reduces the maximum horizontal distance by 3'.

 

c. If you plan to use more than one 90

0

 elbow within the vent system, first use the Venting Requirements Chart (Figure 14) 

and calculate the maximum horizontal run you are allowed based on the first vertical section connected directly to the fire-
place.  From this maximum horizontal run calculated, subtract 3 feet for each additional 90

0

 elbow you will use. 

Example 1:

  Assume you are using a 3 feet long starter vertical section.  This should allow, per figure 15, 15-1/2 feet of 

horizontal run.  If you want to use three 90

0

 elbows, subtract 6 feet for two elbows from the 15-1/2 feet max-

imum allowed [3 feet for each elbow after the first elbow].  This yields 9-1/2 feet as the maximum horizontal 
run that you are allowed to install using the 3 foot vertical starter section. 

CAUTION:

  If a vertical-to-horizontal discharge elbow or a horizontal-to-horizontal discharge elbow is enclosed within a 

wall, floor or ceiling, a top air space clearance of 3" must be maintained. 

USING 45-DEGREE ELBOWS 

Two 45-degree elbows may be used in place of one 90-degree elbow. On 45-degree runs, one foot of diagonal pipe is 
equal to 8-1/2 inches horizontal run and 8-1/2 inches vertical run.  Two 45-degree elbows may be connected directly to 
the vent starter adapter on this fireplace to create an offset to provide the required clearances to combustible framing or 
sheathing materials. 

Two 45-degree elbows may be connected directly to the top of this fireplace to create a horizontal offset.  20 feet maxi-
mum horizontal run allowed with this offset configuration only if the first vertical section connected directly to the last 45-
degree elbow is more than 4 feet long.  For maximum allowable horizontal distances with the 45-degree offsets, see the 
Master Venting Configuration Chart. 

Note:

  Each horizontally positioned 45

º

 elbow reduces the maximum horizontal distance by 1½ '. 

SUPPORT:

  Horizontal runs of pipe will require one vent support for every 3 ft. of pipe. 

 

Содержание FV41-M

Страница 1: ...ation and service must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service...

Страница 2: ...de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions caref...

Страница 3: ...rri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette mesure emp chera les tout petits les jeunes en fants et t...

Страница 4: ...UIREMENTS 19 GENERAL INSTALLATION INSTRUCTIONS 20 GENERAL FLUE VENTING INSTRUCTIONS 21 EXTERIOR VENT LOCATIONS AND RESTRICTIONS 22 FLUE VENTING COMPONENTS IDENTIFICATION 23 FV41 M MASTER FLUE VENTING...

Страница 5: ...Building Code 3 A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a min imum height of eight 8 feet above grade directly in line with the exhaust...

Страница 6: ...LET CONTROLS HARNESSES EXIT GAS SUPPLY INLET 1 2 MNPT GAS TRAIN IGNITION SYSTEM RH BLOWER INSPECTION COVER LH FRAMING ATTACH BRACKETS LH LIFT HANDLE RH FRAMING ATTACH BRACKETS RH BLOWER INSPECTION COV...

Страница 7: ...LES 1in 25mm UNIT BOTTOM TO ENCLOSURE CEILING 48 1 2in 123 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINI...

Страница 8: ...onal service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control com partments burners and circulating...

Страница 9: ...TEL 48 ADJACENT WALLS A wall perpendicular to and in front of this fireplace s glass door surface must be at least 16 inches from the side edges of the facing guide A wall at 45 to the glass surface a...

Страница 10: ...ace Face the combustible mantel may pro trude outward at a Distance up From Floor Level of this Fireplace If you prefer to take measurements from the Top of the Convection Air Opening note that the To...

Страница 11: ...11 P a g e CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES Figure 2 Clearances to Combustibles 0 CLEARANCE FROM TOP STANDOFFS 1 2 CLEARANCE FROM BACK 1 2 CLEARANCE FROM SIDES...

Страница 12: ...surfaces extending full width and depth of this fireplace An R 1 Rated Hearth Protection Pad 1 1 2 Thick Maximum is required unless this fireplace is elevated For every 1 this fireplace is elevated y...

Страница 13: ...ST be adhered to Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems The chase should not break the outside building envelope in any manne...

Страница 14: ...not needed or may be permanently attached using 1 8 rivets that are supplied with this fireplace Inner Guide Identify the Inner Finishing Guides Top Left and Right These guides should be used as a gu...

Страница 15: ...rface Install 1 2 thick drywall on framing members so that its outer surface is flush with the front face of this fireplace Attach Marble or Granite slabs to face of unit and to drywall surface using...

Страница 16: ...floor level and the ceiling All hearth pads must be non combustible metal brick stone or mineral fiberboard Do not use any combustible material to protect the floor in front of this fireplace For the...

Страница 17: ...of the hearth protector may be reduced by 2 inches If fireplace is raised off the floor 6 or more no hearth protector is required HEATING PERFORMANCE With its high heat output this Mendota Fireplace w...

Страница 18: ...ny pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 kPa A proper gas line diameter must be selected to run from the supply regulator to the Firepla...

Страница 19: ...is not sufficient to add the Gas Fireplace an additional inches to inches regulator must be installed for the Fireplace EXCEPTION Some codes allow 2 PSI 1 4KPA supplies to enter the residence in whic...

Страница 20: ...ements and locations are being followed 3 This Fireplace is designed for installation into rough framing NOTE FRAMING MATERIAL ABOVE FIREPLACE MUST MAINTAIN CORRECT CLEARANCE TO FIREPLACE AND VENT PIP...

Страница 21: ...its own separate vent system Common vent systems are prohibited To assure proper venting performance of this high performance Mendota Direct Vent Fireplace it is critical that all brands of vent pipe...

Страница 22: ...K Clearance to a mechanical air supply inlet 6 feet 1 8 m minimum E Clearance to unventilated soffit 24 min 60 cm min L Clearance above paved side walk or a paved driveway located on public property 7...

Страница 23: ...EM DESCRIPTION 1 6 or 7 PIPE DuraVent 6 Amerivent 7 2 12 VENT STACK 3 24 VENT STACK 4 36 VENT STACK 5 48 VENT STACK 6 90 GALVANIZED ELBOW 45 GALVANIZED ELBOW 7 ADJUSTABLE WALL THIMBLE 8 ATTIC INSULATI...

Страница 24: ...feet maximum hori zontal run allowed with a 4 feet starter section If the starter vertical section is less than 4 feet use the chart and reduce 3 feet for every 90 0 elbow in stalled after the first 9...

Страница 25: ...systems that provide a starting vertical section less than 4 feet the following rules apply a You must use the Master Flue Venting Requirements Chart See Zone A below the 4 vertical run line b A sing...

Страница 26: ...L TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS VERTICAL TERMINATION THREE HORIZONTAL DISCHARGE 90 ELBOWS APPROVED w RESTRICTIONS STRAIGHT UP VERTICA...

Страница 27: ...enetrate the exterior wall 3 Cut and frame a 10 3 4 wide x 10 3 4 high opening in the wall The hole must be positioned so the vent system will run level or have a rise per foot of run AND be perpendic...

Страница 28: ...will pass through any ceilings and will penetrate the outside wall Since vent pipe sections overlap we suggest pre assembling and measuring the total vent pipe run so you can more accurately locate t...

Страница 29: ...29 P a g e Figure 19 Figure 20 APPROVED...

Страница 30: ...nts DuraVent only are sealed and are leak proof Maintain 1 airspace clearances to combustibles 2 above horizontal runs Cut a 10 x 10 opening in the roof centered in the small drilled hole placed in th...

Страница 31: ...31 P a g e Figure 21 1 2 3 4 5 13 15 9 10 11 12 50 FEET MAX...

Страница 32: ...fireplace and its venting system Through this effort Mendota has been able to certify the use of Four 90 0 elbows The use of Four 90 0 elbows must meet some minimum prerequisites Prerequisite 1 The v...

Страница 33: ...ree bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center tabs in slots left to right 2 Center Glass Frame over Firebox left to right 3 After...

Страница 34: ...leaks and gas pressures prior to installing facing materials Install fresh batteries in Wall Receiver and remote transmitter Follow Initializing the Sys tem for the first time instructions to synchro...

Страница 35: ...i cations start with air shutter open to 3 8 After burner has been properly installed and operated for 20 minutes small additional adjustments to the air shutter may be ne cessary for final flame appe...

Страница 36: ...ss should be cleaned periodically Exterior glass surface may be cleaned with cleaner as desired To clean interior surface of glass use soap and water CAUTION Do not use oven cleaner to clean glass Cle...

Страница 37: ...eplace if necessary D Periodically check to verify that the vent system and vent cap are open and free of blockage E Before re installing glass have qualified service person check the operation of the...

Страница 38: ...Remove Screws and lift out Burner Airbox Remove 8 screws and remove left side blower mount plate Main Orifice Pilot Hood Valve Pressure Regulator This conversion kit shall be installed by a qualified...

Страница 39: ...wn 5 Remove the Burner Locate and Identify the Burner Orifice Spud The Orifice Spuds can be removed and installed using a deep well socket and ratchet WARNING Make certain to Secure the Brass fit ting...

Страница 40: ...or failure to use only parts specifically ap proved with this appliance may result in property damage or personal injury AVERTISSEMENT Risque de dommages ou de blessures si les pi ces ne sont pas inst...

Страница 41: ...or gas leaks with soap and water solution at all plumbing joints prior to placing this appliance into operation It is recom mended that all gas plumbing joints factory installed and field installed ar...

Страница 42: ...u are derating this appliance at a high altitude also attach the High Altitude Deration Label supplied in the Owner s Manual Packet to this same surface Prior to attaching the labels fill in all the i...

Страница 43: ...Flex CF Coupler 3 1 05 04 00050 SIT Pilot Assembly 4 2 65 14 00038 ORIFICE 38 5 1 05 02 00344 885 PROFLAME SIT VALVE 6 1 65 07 00753 Elbow 90 Deg 3 8 Flared Tube X 3 8 NPT Male Brass 7 1 65 07 00012 B...

Страница 44: ...an Electrical Code Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and danger ous operation and Verify proper operation after servicing Attentio...

Страница 45: ...ts individual components are available through Johnson Gas Appliance Company Contact your dealer for more de tailed ordering information GLASS FRAME ASSEMBLY HA 78 00103 REPLACEMENT PARTS LIST ITEM PA...

Страница 46: ...be found on the rating plate which is located inside the right side controls access door When contacting your dealer for any cleaning service or warranty service always provide the Model Number Seria...

Страница 47: ...runs 1000 sealant must be used on inner joints at adjustable pipe sections CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per M...

Страница 48: ...48 P a g e NOTES...

Страница 49: ...49 P a g e TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Страница 50: ...formance of any part of this limited warranty Mendota has the right to investigate and inspect the exact original Fireplace and entire installation without any alterations or tampering in the event a...

Страница 51: ...51 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com...

Отзывы: