85-03-01103
FV41 ARCH
Page
85
6.7
REPLACEMENT PARTS INFORMATION
How to Access Components
The descriptions below show where the main fireplaces components are located and how to access them for service. The
descriptions show how to access the components after the fireplace has been installed. All components are also accessible from
the outside of the unit before the fireplace is installed.
Pilot
: The pilot is in the center of the firebox between the burners.
Gas Valve
: The main gas valve is located on the left side of the firebox. An inspection panel is provided on the left firebox wall
that allows inspection of the gas valve, wiring, and gas inlet connections.
Complete Valve Assembly
:
To make working on components easier, this fireplace has been designed with the valve, pilot,
shutter boxes, shutter cables and gas lines as part of one assemble that can be removed from the fireplace. To remove the
assembly first remove the inspection panel. This will allow the main gas inlet and wires to the valve, rear burner solenoid and
pilot to be disconnected. After disconnecting the gas line and wires remove the screws from the valve mounting plate (13 on the
left side and two on the floor of the firebox). Then remove the entire assembly from the firebox.
Ignition Control Module
: The ignition control module is mounted on the left side, in a protruding box beyond the main gas valve
(when accessing from inside the firebox). It is secured to the outer wall of the box with two screws. Access to the ignition control
module is available through the inspection panel. First remove the inspection panel. Then locate the ignition control module.
Convection Blowers
: The convection blowers are mounted on the left and right sides of firebox. To access the convection
blowers, remove the left and right firebox side blower access plates.
Accent Light
: The accent light is mounted in the firebox top center area. The accent light wire harness is run from the light
housing to the left side and then down to the ignition control module.
Please contact your Mendota Dealer for parts availability and parts pricing.
General Replacement Parts List
Please contact your Mendota Dealer for parts availability and parts pricing.
ITEM
QTY
PART
NUMBER
DESCRIPTION
1
1
05-02-00344
Valve, 885 ProFlame (NG) SIT# 0.885.001
2
1
05-02-00396
Split Flow Solenoid Valve
3
1
05-04-00065
PILOT, 3-WAY HOOD
4
1
05-02-00381
SIT ProFlame II Control Module, 0.584.306
5
1
65-07-00744
Ball Valve
6
1
65-14-00042
Front Orifice, #42
7
1
65-14-00042
Rear Orifice, #42
8
1
HA-58-00277
Burner Assembly, Rear
9
1
HA-58-00278
Burner Assembly, Front
10
1
05-02-00345
Backup Battery Holder
11
1
10-03-00128
Backup Power Harness
12
1
15-02-00129
Blower, LH
13
1
15-02-00130.
Blower, RH
14
1
10-11-00025
Accent Light Lens
15
1
10-11-00020
G9 Xenon, 25W Light Bulb
16
1
HA-77-00256
Glass Latch Tool
17
1
HA-92-00012
Glass Frame Weldment (no glass), FV41 Arch
18
120”
65-02-00103
Glass Gasket, Tadpole,3/8” Bulb, ¾” Tail
19
1
65-06-01366
Door Glass, NeoCeram
Содержание FV-41
Страница 2: ...85 03 01103 FV41 ARCH Page 2 HOMEOWNER NOTES...
Страница 16: ...85 03 01103 FV41 ARCH Page 16 Figure 3 10 Figure 3 9...
Страница 67: ...85 03 01103 FV41 ARCH Page 67 FEET MAXIMUM...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...