73
Synchronizing the Fireplace and Remote Control
Note:
The master switch and sync switch are located on the
bottom left corner of the fireplace in the left side air gap.
Master Switch”
The master switch acts as the main
safety on/off control for the main gas burners only.
When the master switch is in the off-position, the main
gas burners will not turn on. However, all other
fireplace functions, including the Continuous Pilot
mode (CPI), will operate. When the master switch is in
the on-position, the main burners will function as
designed.
In case of an emergency, toggle the master switch to
off to turn off the main burners.
To synchronize the fireplace and remote control, follow the steps below:
1.
Toggle the
master switch
to “on” (toggle forward).
2.
Locate
sync switch
(above master switch in the right-side air gap). Press the sync button and release. The fireplace will
beep
three
times
indicating that it is ready to synchronize with a remote control. (Note: If you do not hear any beeps when you
press the sync button, contact your Mendota dealer or installer for assistance.)
3.
Within seven seconds, press the “on” button on the remote control. The fireplace will
beep four
times
to indicate that the
remote control’s command is accepted and sets to the particular code of that controller.
Your system is now initialized.
Figure 5-1 Sync Switch
Содержание FV-41
Страница 2: ...85 03 01103 FV41 ARCH Page 2 HOMEOWNER NOTES...
Страница 16: ...85 03 01103 FV41 ARCH Page 16 Figure 3 10 Figure 3 9...
Страница 67: ...85 03 01103 FV41 ARCH Page 67 FEET MAXIMUM...
Страница 95: ......
Страница 96: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...