 REMOTE TRANSMITTER OPERATING INSTRUCTIONS  

TO TURN ON THE APPLIANCE

1.  Press the ON/OFF button.  The transmitter display will show all active icons on the screen.

 

 

2.  Select the Thermostat Mode by pressing the Thermostat Key: OFF (meaning Manual 

Mode), ON (meaning normal Thermostat) or Smart (meaning Smart Mode). 
a.  In OFF (Manual Mode), the appliance will ignite and start on HI. 
b.  In ON (Normal Thermostat Mode), the appliance will only ignite if the Set Temperature 

is greater than the Room Temperature. 

c.  In SMART (Smart Mode), the appliance will only ignite if the Set Temperature is greater 

than the Room Temperature. 

TO TURN OFF THE APPLIANCE

, press the ON/OFF button. 

 

MODE

 KEY 

Pressing the MODE KEY toggles between the various available functions: Flame Height, Fan Speed, Aux (Ac-
cent Light) On/Off and Secondary Burner On/Off. 

 

Flame Height: 

6 flame height Levels are available. While the Flame 

Height Icon is displayed, pressing the Up or Down button 
once will increase or decrease the flame height by 1 of 6 in-
crements. If the flame height is at Level 1 and the Down but-
ton is pressed, all burners will turn OFF. If in IPI mode, the 
pilot light will also extinguish. If in Standing Pilot Mode, the 
pilot light will remain ON. Note: If in SMART model, the flame 

height function is not available for manual adjustment. In SMART mode, 
the flame height regulates automatically.  

 
 
 
 
 
 
 
 

Accent-Light  Dimmer: 

This function controls the Mendota Accent Light 

functions. Pressing the UP key in this mode will TURN ON 
the Accent Light and allow you to control the brightness of the 
Accent Light in 6 steps. A single “beep” will confirm reception 
of the command.  Once you set the desired light brightness, 
the system will remember your selected brightness level until 
you manually change it. 

 
 

 

NOTE: 

The remote control transmitter supplied with the FV41-M model Fireplace will display two additional icons when scrolling 
through using the MODE button. They are shown below. These two icon functions are NOT available for this model and 
must be ignored. Press the MODE button to skip past these two icons to the next available icon.

THESE TWO ICONS ARE 
PRESENT BUT ARE NOT 
FUNCTIONAL. THE FAN 
FUNCTION WILL BE 
ACTIVE IF OPTIONAL 
FANS ARE INSTALLED. 

Содержание FV-41-M-PF2 MODERN

Страница 1: ...n and service must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service tec...

Страница 2: ...CE 8 MODE KEY 8 TEMPERATURE INDICATOR O F OR O C 9 KEY LOCK FUNCTION 9 LOW BATTERY POWER DETECTION 9 OPERATING DURING POWER OUTAGES 9 FIRST TIME PILOT LIGHTING INSTRUCTIONS 10 INITIALIZING THE REMOTE...

Страница 3: ...t appareil doit tre utilis uniquement avec les types de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install SAFETY AND WARNING I...

Страница 4: ...s curit cette mesure emp chera les tout petits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes These units MUST use one of the vent systems described i...

Страница 5: ...in 25mm UNIT BOTTOM TO ENCLOSURE CEILING 48 1 2in 123 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINIMUM C...

Страница 6: ...ally by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments burne...

Страница 7: ...TEMPERATURE window The fan will turn on 5 minutes after fireplace startup and will turn off 12 1 2 minutes after the flames turn off in this mode The flame height can be adjusted while the fireplace i...

Страница 8: ...n crements If the flame height is at Level 1 and the Down but ton is pressed all burners will turn OFF If in IPI mode the pilot light will also extinguish If in Standing Pilot Mode the pilot light wil...

Страница 9: ...sed the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are low a Battery Icon will appear on the LCD display of the Tra...

Страница 10: ...til the pilot flame lights and the pilot is burning steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doin...

Страница 11: ...t light then uses the pilot light to ignite the main burners The pilot light can be set in the CPI Standing Pilot mode to allow the pilot light to remain on indefinitely by setting the Remote Transmit...

Страница 12: ...ACE DOOR 1 With the Glass Door at a sharp angle to the firebox line up the three bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center tabs in...

Страница 13: ...rt with air shutter open to 3 8 After burner has been properly installed and operated for 20 minutes small additional adjustments to the air shutter may be necessary for final flame appearance These s...

Страница 14: ...that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts can be ca...

Страница 15: ...15 P a g e...

Страница 16: ...16 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com 85 03 00890...

Отзывы: