Mendota FV-41-M-PF2 MODERN Скачать руководство пользователя страница 10

10 | P a g e  

 

MASTER SWITCH ON 

SYNC SWITCH 

MASTER SWITCH ON 

SYNC SWITCH 

“FIRST TIME” PILOT LIGHTING INSTRUCTIONS 

IMPORTANT:

  Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed! 

CAUTION:

  If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot. 

1.  Make certain that any manual gas supply shut-off valves located upstream of 

fireplace are open and the Master On/Off switch is toggled to the ON position.   

2.  Make certain that 110VAC power is connected to Electrical Junction Box on left 

side of Fireplace and that the Electrical Power is “ON”. 

3.  Insert Batteries in the Remote Transmitter. Note the polarity of batteries and 

insert as indicated on the battery compartment cover. 

4.  For the “First Time Lighting”, Remove the Glass Door. This is required to purge 

the gas line of air and to inspect the pilot lighting spark. 

5.  Press OFF on the remote Transmitter. Press MODE button on Transmitter. 

Press UP for “CPI” (standing pilot mode). Press MODE button again to exit. You 
will hear a series of clicks and after a few seconds, you will hear sparking at the 
pilot spark electrode. 

6.  Allow adequate time for the air in the gas-line to purge. The control system will 

stop sparking after 30 seconds if the pilot light does not light. After a 30 second 
delay the control system will start sparking again for 30 seconds more.  If the pilot light does not light after the third 30 
second spark event, the system will enter “Lock-out” mode. To unlock from “Lock-out” mode, Press the ON/OFF but-
ton on Transmitter then Press ON/OFF button on the transmitter again so the Transmitter display turns off. Wait 30 
seconds. Turn OFF the Master Switch. Wait 30 seconds and Turn Master Switch ON again. Repeat this sequence un-
til the pilot flame lights and the pilot is burning steadily.  

7.

  Once the pilot flame is lit and well-established, close glass door.  

WARNING: NEVER IGNITE MAIN BURNERS WITH 

GLASS DOOR REMOVED OR OPEN. Doing so will lead to damage to pilot flame sensor and spark electrode 
wire leads.

 

8.

  Press the ON/OFF button on Transmitter to “ON”. All burners should ignite 

and run at “high-fire”.  Toggle through other functions of the Fireplace 
(Flame Height, Fan Speed and Accent Light brightness) to verify all func-
tions. 

9.

  Perform gas inlet and outlet pressure tests and leak tests on field installed 

gas fittings and factory installed fittings in the gas valve compartment, at this 
time. Note: Burners must be ON to check outlet pressures and to leak test 
gas train fittings upstream of main gas valve. 

INITIALIZING THE REMOTE CONTROL SYSTEM 

MASTER SWITCH: Remote Transmitter WILL NOT communicate to receiver 
unless the Master Switch is ON. The master switch when OFF disables all 
functions and acts as a Master Safety Shutoff Switch.

 

(Synchronizing Receiver and Transmitter) 

Master Switch and Sync Switch are located at the bottom left corner of the Glass 
Frame. 

1.  Toggle Master Switch to ON (pull toward front of unit). Remote Transmitter 

WILL NOT communicate to receiver unless the Master Switch is ON. 

2.  Locate Sync Switch (directly above Master Switch). Press the Sync Button. The 

receiver will beep 3 times indicating that it is ready to synchronize with a Re-
mote Transmitter. 

3.  Push the “ON” key on the Remote Transmitter. The receiver will beep 4 times to 

indicate that the Transmitter’s command is accepted and sets to the particular 
code of that Transmitter.  The system is now initialized. 

NOTE

: Once synchronized, the Transmitter and Receivers will communicate per-

manently and no further Synchronizing steps are necessary unless either the 
Transmitter or Receiver is replaced. 

 

 

 

REMOTE TRANSMITTER

BLUE LCD
DISPLAY

MODE
SELECTION KEY

UP/DOWN
SELECTION KEY

THERMOSTAT

SELECTION KEY

ON/OFF KEY

Содержание FV-41-M-PF2 MODERN

Страница 1: ...n and service must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service tec...

Страница 2: ...CE 8 MODE KEY 8 TEMPERATURE INDICATOR O F OR O C 9 KEY LOCK FUNCTION 9 LOW BATTERY POWER DETECTION 9 OPERATING DURING POWER OUTAGES 9 FIRST TIME PILOT LIGHTING INSTRUCTIONS 10 INITIALIZING THE REMOTE...

Страница 3: ...t appareil doit tre utilis uniquement avec les types de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install SAFETY AND WARNING I...

Страница 4: ...s curit cette mesure emp chera les tout petits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes These units MUST use one of the vent systems described i...

Страница 5: ...in 25mm UNIT BOTTOM TO ENCLOSURE CEILING 48 1 2in 123 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINIMUM C...

Страница 6: ...ally by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments burne...

Страница 7: ...TEMPERATURE window The fan will turn on 5 minutes after fireplace startup and will turn off 12 1 2 minutes after the flames turn off in this mode The flame height can be adjusted while the fireplace i...

Страница 8: ...n crements If the flame height is at Level 1 and the Down but ton is pressed all burners will turn OFF If in IPI mode the pilot light will also extinguish If in Standing Pilot Mode the pilot light wil...

Страница 9: ...sed the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are low a Battery Icon will appear on the LCD display of the Tra...

Страница 10: ...til the pilot flame lights and the pilot is burning steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doin...

Страница 11: ...t light then uses the pilot light to ignite the main burners The pilot light can be set in the CPI Standing Pilot mode to allow the pilot light to remain on indefinitely by setting the Remote Transmit...

Страница 12: ...ACE DOOR 1 With the Glass Door at a sharp angle to the firebox line up the three bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center tabs in...

Страница 13: ...rt with air shutter open to 3 8 After burner has been properly installed and operated for 20 minutes small additional adjustments to the air shutter may be necessary for final flame appearance These s...

Страница 14: ...that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts can be ca...

Страница 15: ...15 P a g e...

Страница 16: ...16 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com 85 03 00890...

Отзывы: