11 | P a g e  

 

ATTENTION! 

The transmitter and receiver are RADIO FREQUENCY DEVICES.  Placing the receiver in or near metal may 
severely reduce the signal range. 

 

Turn off the main gas supply of the appliance during installation or maintenance of the receiver. 

 

Place the receiver’s 3-position slider switch in the “off” position during installation or maintenance. 

 

Turn “off” main gas supply to the appliance prior to removing or reinserting the batteries in the receiver. 

 

During appliance installation/maintenance or in case of remote control malfunction, turn off electrical supply to 
this appliance and remove the batteries from the wall receiver battery compartment. Contact technical service. 

 

ATTENTION! 

The transmitter and receiver are RADIO FREQUENCY DEVICES.  Placing the receiver in or near metal may 
severely reduce the signal range. 

 

Turn off the main gas supply of the appliance during installation or maintenance of the receiver. 

 

Toggle the Master Switch to OFF during installation or maintenance. 

 

Turn “off” main gas supply to the appliance prior to removing or reinserting the batteries in the receiver. 

 

During appliance installation/maintenance or in case of remote control malfunction, turn off electrical supply to 
this appliance and disconnect the Backup batteries from the wall DC connector. Contact technical service. 

 

 

 

IPI/STANDING PILOT SYSTEM INFORMATION 

 

 

Intermittent Pilot Light and Standing Pilot Light Features 

This gas fireplace is equipped with an electronic ignition System that first lights a pilot light then uses the pilot light to ignite 
the main burners.  The pilot light can be set in the CPI (Standing Pilot) mode to allow the pilot light to remain on indefinitely 
by setting the Remote Transmitter to CPI mode.  If the remote transmitter is set to the IPI (Intermittent Pilot) mode, the 
pilot light will only light and remain ON while the main fireplace burners are operating. 

IPI Mode:  This mode turns the pilot light “OFF” when the fireplace is not functioning and only lights the pilot light automati-
cally when a call for heat is made by the remote con-
trol. 

(CPI)  Standing Pilot Mode: If set to CPI Mode, the 
pilot light will ignite and remain ON at all times. 

 

Setting to IPI versus CPI mode: 

With the remote transmitter OFF, press the 
MODE button. You will see either “CPI” or 
“IPI” displayed on the transmitter screen. 
Press the UP arrow button to set “CPI” mode 
and press the DOWN arrow button to set “IPI” 
mode. Once set to the desired setting, press On/Off button to activate the fireplace. 

NOTE

Mendota Fireplaces recommends that the (CPI) Standing Pilot Mode be used during the winter months 

when the average daily high temperature falls below 50

o

F

. This will keep the fireplace chimney heated for proper up-

draft during burner ignition and it will also eliminate excessive condensation of exhaust vapors on the door glass.  Further, 
leaving the fireplace in the Standing Pilot Mode will keep the fireplace body warm and eliminate cold drafts and heat loss to 
the cold air that is trapped inside the firebox. 

 

REMOTE CONTROL 

WALL RECEIVER 

Supply voltage 

4.5V (three 1.5V AAA batteries) 

6.0V (four 1.5V AA batteries) 

Ambient temperature ratings 

32 – 122 

o

F (0 – 50 

o

C) 

32 – 140 

o

F (0 – 60 

o

C) 

Radio Frequency 

315 MHz 

315 MHz 

Содержание FV-41-M-PF2 MODERN

Страница 1: ...n and service must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service tec...

Страница 2: ...CE 8 MODE KEY 8 TEMPERATURE INDICATOR O F OR O C 9 KEY LOCK FUNCTION 9 LOW BATTERY POWER DETECTION 9 OPERATING DURING POWER OUTAGES 9 FIRST TIME PILOT LIGHTING INSTRUCTIONS 10 INITIALIZING THE REMOTE...

Страница 3: ...t appareil doit tre utilis uniquement avec les types de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install SAFETY AND WARNING I...

Страница 4: ...s curit cette mesure emp chera les tout petits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes These units MUST use one of the vent systems described i...

Страница 5: ...in 25mm UNIT BOTTOM TO ENCLOSURE CEILING 48 1 2in 123 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINIMUM C...

Страница 6: ...ally by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments burne...

Страница 7: ...TEMPERATURE window The fan will turn on 5 minutes after fireplace startup and will turn off 12 1 2 minutes after the flames turn off in this mode The flame height can be adjusted while the fireplace i...

Страница 8: ...n crements If the flame height is at Level 1 and the Down but ton is pressed all burners will turn OFF If in IPI mode the pilot light will also extinguish If in Standing Pilot Mode the pilot light wil...

Страница 9: ...sed the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are low a Battery Icon will appear on the LCD display of the Tra...

Страница 10: ...til the pilot flame lights and the pilot is burning steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doin...

Страница 11: ...t light then uses the pilot light to ignite the main burners The pilot light can be set in the CPI Standing Pilot mode to allow the pilot light to remain on indefinitely by setting the Remote Transmit...

Страница 12: ...ACE DOOR 1 With the Glass Door at a sharp angle to the firebox line up the three bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center tabs in...

Страница 13: ...rt with air shutter open to 3 8 After burner has been properly installed and operated for 20 minutes small additional adjustments to the air shutter may be necessary for final flame appearance These s...

Страница 14: ...that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts can be ca...

Страница 15: ...15 P a g e...

Страница 16: ...16 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com 85 03 00890...

Отзывы: