Factory Installed Manual Gas Shutoff Valve
A manual gas shutoff valve is factory installed and located in the left-side convection chamber. To operate the manual gas
shutoff valve, insert the tip of the glass latch tool into the hole in the valve activation bracket. Rotate the tool 90-Degrees
counter clockwise or until it stops to fully close the Valve. To open valve, insert tool in valve activation bracket and rotate 90-
degrees clockwise or until it stops.
Figure 3-32 EMERGENCY GAS SHUTOFF
Gas Inlet Fittings Information
Caution: Before you run the gas line, read, understand and properly calculate the required gas line size.
Improper (too small) gas line size application can lead to improper burner ignition and can cause property
damage and/or injury. If you are not qualified or certified to run a gas line, do not proceed. Contact a
qualified Gas Plumber.
The gas inlet fitting supplied with this Fireplace provides a 1/2
”
female NPT fitting.
This requires you to supply a ½” NPT male
fitting for connection to this appliance.
Based on the gas line size you have selected use an appropriate NPT fitting to adapt and connect to the 1/2
” male NPT flex end
adapter.