     85-03-01096

 

PLANNING FOR VENT LOCATION 

TV Installation Above Fireplace 

An advantage of installing a Cool Wall Vent Kit with your fireplace is being able to install a television above the fireplace. 
Using a Cool Wall Kit 

can make it possible to install a television above the fireplace. These instructions show Mendota’s 

recommendations of installing a television above the fireplace when using a Cool Wall Kit.  

When planning to install a television or other heat sensitive product above your fireplace, there are some points to consider. 

Many television manufacturers specify in their installation instructions that the television must not be installed near or above 
a heat source. The decision to install a television near or above a Mendota fireplace rests solely on the consumer. It is the 
consumers responsibility to satisfy television specifications and insure the television  will  not exceed maximum operation 
temperatures. Mendota Hearth will not be held liable for any adverse effects on a television or other products located near 
to a Mendota Hearth fireplace. 

The drawing below shows  a recommendation  that may  be used as a  guide for those consumers that decide to locate  a 
television above a Mendota Hearth fireplace. The recommendation has been found to reduce the heat impact to a television 
when installed above a Mendota Hearth fireplace.  
 
 
Recommendation for Installing a Television Using a Cool Wall Vent Kit.  
 

WARNING: 

The  convection  fans  on  the  fireplace  must  be  turned  off  to  insure  the  heat  from  the  fireplace  is  redirected 

through the Cool Wall Vent Kit. Turning the convection fans on will force heated air out the front of the fireplace, heating the 
surrounding area. 

-

 

On fireplaces with a millivolt system: DXV35 Timberfire, DXV42, DXV60, M50 the convection fans must be 
disconnected from power to insure they cannot be turned on.  

-

 

On fireplaces with electronic ignition system that come with a PF2 remote the convection fans function must be 
programed out of the remote. This will ensure that the convection fans cannot be turned on. Follow the directions 
below to remove the convection fans function from the remote. 

1.  Remove a battery from the remote. 
2.  Hold down both the ON/OFF key and MODE key 

and reinstall the battery. 

3.  Continue to hold the ON/OFF key. Release the 

MODE key. Press the MODE key once to 
highlight the convection 

fan function.  

 

4.  While still holding the ON/OFF key press the 

DOWN ARROW key. The display will change 
from “Set” to “Clr” to indicate that the convection 
fan function has been disabled. 

5.  Release the ON/OFF key. 

 
 

 

Содержание AA-11-03781

Страница 1: ...stallation manual to insure proper installation These kits are designed to use natural convection to transfer warm air from the front of the fireplace to a different location The kits allow the warm a...

Страница 2: ...all Vent Kit 7 AESTHETIC CONSIDERATIONS 9 AA 11 03781 48 X 2 VENT BOX AND TRIM KIT 9 AA 11 03782 36 X 2 VENT BOX AND TRIM KIT 10 AA 11 04062 DUAL 12 X 4 VENT BOX KIT 10 MINIMUM FRAMING DIMENSIONS 11 4...

Страница 3: ...warm air to another room The Cool Wall vents are approved for horizontal discharge only They cannot be located in a ceiling or any other unapproved application WARNING The Cool Wall vent can be locate...

Страница 4: ...1 HA 117 00005 VENT GUIDE BOTTOM 1 HA 117 00004 VENT GUIDE TOP 1 HA 117 00006 SUPPORT BRACKET 2 HA 118 00002 48 X 2 VENT TRIM 1 50 01 00102 8 X SELF DRILLING SCREW 30 THE FOLLOWING ARE INCLUDED IN THE...

Страница 5: ...17 00015 VENT GUIDE BOTTOM 1 HA 117 00014 VENT GUIDE TOP 1 HA 117 00006 SUPPORT BRACKET 2 HA 118 00004 36 X 2 VENT TRIM 1 50 01 00102 8 X SELF DRILLING SCREW 30 THE FOLLOWING ARE INCLUDED IN THE AA 11...

Страница 6: ...0020 VENT GUIDE BOTTOM 2 HA 117 00019 VENT GUIDE TOP 2 HA 117 00006 SUPPORT BRACKET 4 65 06 01453 12 X 4 SIDEWALL GRILL 2 50 01 00102 8 X SELF DRILLING SCREW 50 THE FOLLOWING ARE INCLUDED IN THE AA 11...

Страница 7: ...ide to locate a television above a Mendota Hearth fireplace The recommendation has been found to reduce the heat impact to a television when installed above a Mendota Hearth fireplace Recommendation f...

Страница 8: ...nd away from surrounding areas Testing has shown that when using a Cool Wall system temperatures above the fireplace are reduced making it possible to mount a television 15 above the fireplace s top a...

Страница 9: ...nted to match room d cor if desired It is recommended that this 48 vent box be used with fireplaces that have a glass width of close to 48 or more However it can also be used on smaller fireplace if d...

Страница 10: ...will need to be increased to accommodate the vent Be sure to understand all framing requirements of both the fireplace and vent box and trim kit before installation INSTALLED WITH ML72 FIREPLACE INSTA...

Страница 11: ...ill affect the placement of the fireplace and these vent kits before beginning construction NOTE The vent guides for each vent box are designed to insure clearance to combustible material is meet The...

Страница 12: ...guides the bottom framing 2x4 must be at least 24 above the top of the fireplace HORIZONTAL OFFSET When the vent box is placed in a location that requires the flex vent to be offset horizontally a ma...

Страница 13: ...epth the dual 12 x 4 cool wall vent box and trim kit could be used and installed so that the fireplace direct vent duct passes between the cool wall kit vent ducts NOTE The fireplace direct vent duct...

Страница 14: ...ircular cutout Use a side cutter or tin snips to cut the tabs around the perimeter of the circle and remove the cut out 3 Remove any loose pieces of insulation and push the insulation away from the in...

Страница 15: ...ars To install the starter collars slide the end with the tabs through the 8 holes on the bottom of the vent Then bend over all the tabs to hold the starter collar in place 2 Each vent box kit comes w...

Страница 16: ...ent The other vent sizes install in the same way 1 The first step is to fasten the framing guide to the framing The opening in the framing guide will determine where the vent is located The vent slot...

Страница 17: ...ming The bottom of the brackets rest against the bottom framing 2 x 4 and can be pushed up against the framing guide plate The side of the bracket with one row of holes must be facing up 3 Slide the v...

Страница 18: ...ishing material around the vent will be so that the vent box outlet can be set at the correct depth Set the distance the vent box protrudes out from the framing guide to match the thickness of finishi...

Страница 19: ...ht between the two connections Use the 8 hose clamps to hold the flex vent to the starter collars on the vent box and rigid pipe on the unit In addition to the hose clamps a couple self drilling screw...

Страница 20: ...trim into the vent box opening Push the trim tight against the wall Self drilling screws can be used to secure the trim to the side of the vent box opening For 12 x 4 vent Once the finishing material...

Страница 21: ...On fireplaces with electronic ignition system that come with a PF2 remote the convection fans function must be programed out of the remote This will ensure that the convection fans cannot be turned o...

Страница 22: ...Page 22 of 22 85 03 01096...

Отзывы: