23 | 

P a g e

 

 

INSTALLATION OF FLAT PANEL TV ON TOP OF ML47 

All flat panel TVs are solid state electronic appliances and are vulnerable to ambient temperatures greater than 90

o

F. 

The ML47 is a gas fired heater and high ambient temperatures are to be expected in the immediate vicinity of this fire-
place.  
If the installation of a Flat Panel TV is de-
sired above this appliance, proceed with 
caution. Follow the specific framing dimen-
sion and instructions provided below. Men-
dota does not warrant any TV installed 
above a Mendota Fireplace against heat 
damage. 
Given, below, is the minimum TV Cavity 
framing and creation method. If possible, 
increase the distance between the top 
edge of the top convection air opening of 
this fireplace and the bottom edge of the 
TV cavity as much as possible beyond the 
18” minimum requirement. Higher up 
means a cooler TV. 
You MUST create a recessed 5” deep cav-
ity to house the TV. NEVER mount any TV 
above this fireplace without creating a re-
cessed cavity. 

Framing the TV Recessed Cavity 

Use 2x6 lumber to create the basic frame 
for the TV cavity. Front edge of 2x6 
lumber shall be flush with the front 
edge of the top rough framing 2x4 
member. Locate the bottom 2x6 so 
its top surface is a minimum 18” 
above the top edge of the top con-
vection air opening of this fireplace. 
Allow more distance if the ceiling 
height allows rather than using the 
18” minimum. 
The finished recessed cavity shall 
be 6” wider than the TV width, 6” 
taller than the TV height and 5” 
deep. Avoid using TV mounting 
brackets that are too deep. The 
TV’s front-most surface must be re-
cessed inward in the cavity at least 
2 inches from the front surface of 
the final finish material. 
 
 
 
 
 
 
 

 

Содержание AA-11-02592

Страница 1: ...e department Installation and service must be performed by a qualified installer service agency or the gas sup plier WARNING Do NOT use this appliance if any part has been under water Immediately call...

Страница 2: ...appareil et remplacer toute partie du syst me de contr le et toute commande qui ont t plong s dans l lau In the Commonwealth of Massachusetts Installation must be performed by a licensed plumber or g...

Страница 3: ...staller une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le in stallez une barri re de s curit cette mesure emp chera les tout petits les jeune...

Страница 4: ...20 RAISED HEIGHT INSTALLATION OF ML47 21 How to determine the proper installed height of this fireplace 22 INSTALLATION OF FLAT PANEL TV ON TOP OF ML47 23 ENAMEL PANORAMIC LINER AND FLOOR PLATE INSTA...

Страница 5: ...ENTS 45 LOCATION OF MASTER SWITCH AND SYNC SWITCH 46 Remote Control Transmitter Functions 47 REMOTE TRANSMITTER OPERATING INSTRUCTIONS 48 FIRST TIME PILOT LIGHTING INSTRUCTIONS 50 IPI STANDING PILOT S...

Страница 6: ...e Building Code A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust v...

Страница 7: ...SIONS OVERALL APPLIANCE DIMENSIONS AND FEATURES Removable Cover Plate for Plumbing Electrical Access before unit is placed inside framed cavity Replace Lower Cover Plate before sliding unit into frame...

Страница 8: ...em 120VAC 2 Amps Dedicated Hot Power only No switches Fan Speed Controls or Light Dimmers are allowed in the same AC supply circuit Optional fans are controlled using re mote control ACCENT LIGHT SYST...

Страница 9: ...T TO FLOOR 0in 0mm GLASS EDGE TO ADJACENT SIDEWALL 16in 406 mm UNIT TO ENCLOSURE SIDEWALL 1 2in 13mm VENT PIPE TOP TO COMBUSTIBLES 3in 76mm UNIT TO ENCLOSURE BACK WALL 1 2in 13mm VENT PIPE SIDES TO CO...

Страница 10: ...be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments burners and circulating air passageways of the appliance be kept clean...

Страница 11: ...N INFORMATION Prior to installing at altitudes higher than 7500 please contact the Mendota technical service department for specific venting requirements and venting restrictions MINIMUM ROUGH FRAMING...

Страница 12: ...distance up from the Floor Level of this Fireplace If you prefer to take measurements from the Top of the Convection Air Opening note that the Top of the convection air opening is 25 1 16 inches up f...

Страница 13: ...more 16 in from of the front surface of the visi ble glass door and if perpendicular to the front surface of the glass door must be located a minimum of 16 from the side edge of the visible glass doo...

Страница 14: ...nd ceiling fan are desired Selecting Appliance Location When selecting a location for your appliance it is important to consider the required clearances to adjacent side walls Figure 2 Planning Instal...

Страница 15: ...e to prevent cold air drafting problems The chase should not break the outside building envelope in any manner Wall ceiling base plate and cantilever floor of the chase should be insulated Vapor and a...

Страница 16: ...ition the finishing mate rial s edges adjacent to the top sides and bottom convection air gap around the glass frame Use the Inner Guide if you installing only the Traditions or Willowbrook Front or i...

Страница 17: ...ace s rectangle profile must extend out from the face surface of this fireplace 1 inch if the 19 1 2 framing depth is used and the Inner or Outer Finishing Guides are utlizied A MAXIMUM THICKNESS OF 2...

Страница 18: ...p to 1 maximum The Traditions Front can be close to the glass frame or away from the glass frame This front comes with a screen and is a conforming safety barrier For the Traditions Front use the inne...

Страница 19: ...e Framing Brackets With Final Finishing Material mounted behind the Grace by using the inner guides the Grace can be mounted only as close as the Final Finishing Ma terial thickness allows This front...

Страница 20: ...k as allowed by the Final Finish Material thickness Mount the Traditions or Willow brook Front at the desired depth relative to the Grace Front Note that the Traditions or Willowbrook Front s visible...

Страница 21: ...ce from Floor to ML47 Bottom Surface DIM A MAXIMUM Distance from Floor to ML47 Visible Glass Bot tom Edge DIM B LIMITATIONS MUST BE ADHERED TO 84 15 24 3 16 LIMITED by Clearance to Soffit Use metal sh...

Страница 22: ...e of the visible glass will be located 9 3 16 up from the floor level in this configuration Mendota recommends that the ML47 be installed on an elevated wood framed support stand of at least 15 tall w...

Страница 23: ...bottom edge of the TV cavity as much as possible beyond the 18 minimum requirement Higher up means a cooler TV You MUST create a recessed 5 deep cav ity to house the TV NEVER mount any TV above this f...

Страница 24: ...r Mocha Metallic and Silver Metallic attractive colors You must select one col ored Panoramic Panel Kit and install it before any test firing of this appliance The specific color kits and its correspo...

Страница 25: ...mounting height of this single gang box with the height of other AC outlets that are installed in the same room as this appliance WARNING DO NOT STAPLE the 6 DC Power Inlet Harness to the wall studs C...

Страница 26: ...stalled at a minimum of 12 above the heat outlet 37 up from the floor level of this fireplace and no more than 8 out from wall at that height Non combustible marble brick stone etc mantels can be inst...

Страница 27: ...e correct pipe sizes PIPE LENGTH FEET SCHEDULE 40 PIPE INSIDE DIA TUBING TYPE L OUTSIDE DIA NAT L P NAT L P 0 10 1 2 1 3 cm 3 8 1 0 cm 1 2 1 3 cm 3 8 1 0 cm 10 40 1 2 1 3 cm 1 2 1 3 cm 5 8 1 6 cm 1 2...

Страница 28: ...his table GAS PRESSURE REQUIREMENTS NOTE For altitudes above 2 000 feet some variations in air shutter settings may be required Figure 4 Gas Valve Pressure Test Ports Manifold pressure must be taken a...

Страница 29: ...the 30 minutes of burn time Write the reading here Final Gas Meter Reading _______________ Calculate the following FINAL GAS METER READING INITIAL GAS METER READING Subtract Initial Gas Meter from Fin...

Страница 30: ...prepare the rough opening using framing dimensions Be sure to also prepare opening to allow for co axial vent 2 Check to make certain all venting requirements and locations are being followed 3 This...

Страница 31: ...e its own separate vent system Common vent systems are prohibited To assure proper venting performance of this high performance Mendota Direct Vent Fireplace it is critical that all brands of vent pip...

Страница 32: ...erminal 18 47 cm min K Clearance to a mechanical air supply inlet 6 feet 1 8 m minimum E Clearance to unventilated soffit 18 min 46 cm min L Clearance above paved side walk or a paved driveway located...

Страница 33: ...M DESCRIPTION 1 6 or 7 PIPE DuraVent 6 Amerivent 7 2 12 VENT STACK 3 24 VENT STACK 4 36 VENT STACK 5 48 VENT STACK 6 90 GALVANIZED ELBOW 45 GALVANIZED ELBOW 7 ADJUSTABLE WALL THIMBLE not shown 8 ATTIC...

Страница 34: ...is 4 In Zone A 32 feet maximum horizontal run allowed with a 4 feet starter section for NG and 27 feet maximum horizontal for LPG If the starter vertical section is less than 4 feet use the chart and...

Страница 35: ...rtical section less than 4 feet the following rules apply a You must use the Master Flue Venting Requirements Chart See Zone A below the 4 vertical run line b A single 90 vertical to horizontal elbow...

Страница 36: ...LBOWS VERTICAL TERMINATION VERTICAL RISE DUAL 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS VERTICAL TERMINATION THREE HORIZONTA...

Страница 37: ...10 3 4 high opening in the wall The hole must be positioned so the vent system will run level or have a rise per foot of run AND be per pendicular to the wall The height of the opening must be locate...

Страница 38: ...netrate the outside wall See Figure 13 Be sure all vent components are properly twist locked and leak proof Be sure 1000 sealant is used in the inner pipe joints of all pipe sections manufactured by S...

Страница 39: ...ft 10 ft 28 ft 10 ft 40 ft Varies V1 min H1 max V2 max H2 max 18 in 6 in 36 1 2 ft 42 ft H1 V2 24 in 6 ft 32 ft 34 ft 42 ft H1 V2 30 in 13 ft 27 1 2 ft 42 ft H1 V2 36 in 19 ft 20 ft 42 ft H1 V2 42 in...

Страница 40: ...nts DuraVent only are sealed and are leak proof Maintain 1 airspace clearances to combustibles 2 above horizontal runs Cut a 10 x 10 opening in the roof centered in the small drilled hole placed in th...

Страница 41: ...e V1 min H max V2 max 18 in 6 in 38 1 2 ft 24 in 6 ft 34 ft 30 in 13 ft 27 ft 36 in 19 ft 21 ft 42 in 25 1 2 ft 14 1 2 ft 48 in 32 ft 10 ft 4 ft 10 ft 32 ft Varies 10 ft 40 ft Varies Varies Figure 17...

Страница 42: ...ws must meet some minimum prerequisites Prerequisite 1 The vent system must terminate vertically using a vertical vent cap Prerequisite 2 There must be a minimum 12 inches of vertical starter section...

Страница 43: ...t and right corners of glass frame Identify a rec tangle slot on the bottom right and left corners of firebox opening sides Carefully line up the bottom corner tabs in glass frame bottom corners with...

Страница 44: ...Check Off List see above must be completed q Check for gas leaks and gas pressures prior to installing facing materials q Install fresh batteries in remote transmitter Follow Initializing the System...

Страница 45: ...nd burner media are positioned properly For Natural Gas applications air shutter shall be 1 8 open For LPG applications start with air shutter open to 3 8 After burner has been properly installed and...

Страница 46: ...actuate the two switches The Master Switch must be ON for the pilot flame and burner flames to activate The SYNC switch is to be used initially when mating the remote transmitter with the receiver lo...

Страница 47: ...replace will stay functioning until the room temperature increases 1o F above the Set Point Temperature To increase the Set Point Temperature Press the UP button until the desired temperature is displ...

Страница 48: ...vel 1 and the Down but ton is pressed all burners will turn OFF If in IPI mode the pilot light will also extinguish If in Standing Pilot Mode the pilot light will remain ON Note If in SMART model the...

Страница 49: ...to the room thermostat set point etc When the Transmitter batteries are low a Battery Icon will appear on the LCD display of the Transmitter before all battery power is lost When the batteries are rep...

Страница 50: ...the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doing so will lead to damage to pilot flame sensor and spark electrode w...

Страница 51: ...e door glass Further leaving the fireplace in the Standing Pilot Mode will keep the fireplace body warm and eliminate cold drafts and heat loss to the cold air that is trapped inside the firebox REMOT...

Страница 52: ...he pilot light flame Use the IPI mode instead during summer months CLEANING VIEWING GLASS The viewing glass should be cleaned periodically Exterior glass surface may be cleaned with cleaner as desired...

Страница 53: ...f necessary C Periodically check to verify that the vent system and vent cap are open and free of blockage D Before re installing glass have qualified service person check the operation of the pilot a...

Страница 54: ...r plate remove main burner Locate two access plates on the left and right side of firebox floor See diagrams below Unscrew seven outer screws and lift entire left or right cover plate assem bly which...

Страница 55: ...e and the Valve Pressure Regulator This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of...

Страница 56: ...ner Orifice Spud The Orifice Spud can be removed and installed using a hex wrench WARNING Make certain to Secure the Brass fitting and flex supply tube attached to the orifice in place using a 1 2 ope...

Страница 57: ...or failure to use only parts specifically ap proved with this appliance may result in property damage or personal injury AVERTISSEMENT Risque de dommages ou de blessures si les pi ces ne sont pas inst...

Страница 58: ...s recom mended that all gas plumbing joints factory installed and field installed are checked for leaks Figure 19 Pressure Test Port PILOT FLAME AND MAIN BURNER RELATIONSHIP VERIFICATION Prior to comp...

Страница 59: ...59 P a g e 1 MIN 1 MIN...

Страница 60: ...lied in the Owner s Manual Packet to this same surface Prior to attaching the labels fill in all the information that is requested in these labels For installations from 610 1370 meters 2000 4500 ft t...

Страница 61: ...ALVE ASSEMBLY REPLACEMENT PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 1 05 04 00062 Pilot Assembly 2 2 65 14 00180 ORIFICE 1 8 3 1 HA 90 00004 Proflame Valve Assembly with fittings 4 1 55 02 00070 T...

Страница 62: ...cal Code Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and danger ous operation and Verify proper operation after servicing Attention Au momen...

Страница 63: ...y Con tact your dealer for more detailed ordering information Figure 22 GLASS FRAME ASSEMBLY HA 90 00102 REPLACEMENT PARTS LIST ITEM PART NUMBER DESCRIPTION 1 HA 90 00103 FRAME WELDMENT GLASS ML47 2 6...

Страница 64: ...ound on the rating plate which is located in the air gap below the glass frame near the center When contacting your dealer for any cleaning service or warranty service always provide the Model Number...

Страница 65: ...65 P a g e THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 66: ...66 P a g e THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 67: ...d and leak proof Check minimum and maximum vertical horizontal and vent runs 1000 sealant must be used on inner joints at adjustable pipe sections q CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LO...

Страница 68: ...68 P a g e TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Страница 69: ...ases that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts can b...

Страница 70: ...70 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com 85 03 00923...

Отзывы: