Flue gas flow rate
Wood /coal

Test flue gas temperature
wood /coal

@ pascals of pressure

Loxton 3

3.6

/4.1g/sec

253/243 deg C

12 pa

Tested Gas flow rates flue

gas temperatures

Chimney Connec�on

In order for the stove to perform sa�sfactorily the chimney height must be sufficient to ensure an

adequate draught to clear the products of combus�on and prevent smoke problems into the room.

Stove model

Weight &

Nominal heat output for Wood and Smokeless fuels

Loxton 3

Log length

Wood reload

Weight wood load

Wood Size

Coal reload

Weight coal (anth)

20cm

1hr

700 g

25 x 7 x 10cm

2hr

700 g

Output
wood
fuel

Efficiency CO@13%

o2

Recommended
for smoke control
Oct 2012

Minimum
Posi�on air
stop SE model

Output coal
fuel

Efficiency

CO@13%
o2

Loxton 3

4.0kw

81.4%

0.06

Yes / SE model

25%

4.0kW

80.9%

0.05

(5mm min air)

NOTE: A chimney height of not less than 4.5 metres measured ver�cally from the outlet of the stove

to the top of the chimney should be sa�sfactory. Alternately the calcula�on procedure given in

BS 5854:1980 may be used as the basis for deciding whether a par�cular chimney design will provide

sufficient draught.

The outlet from the chimney should be above the roof of the building in accordance with the provisions

of Building Regula�ons Approved Document J. If installa�on is into an exis�ng chimney then it must be

sound and have no cracks or other faults which might allow fumes into the house. Older proper�es, especially,

may have chimney faults or the cross sec�on may be too large .

Mendip Stoves recommend the use of a solid fuel flue lining system for all installa�ons into exis�ng chimneys.

All chimney systems must be used in accordance with Building Regula�ons Approved Document J.
If an exis�ng chimney is used the chimney must be clear of obstruc�on and be swept clean immediately before

installa�on of the stove. The chimney should be tested to confirm the chimney will provide the correct chimney

pressure for the stove. If the stove is fi�ed in place of an open fire the chimney should be swept one month

a�er installa�on to clear any soot falls which may have occurred due to the difference in combus�on between

the stove and the open fire. If there is no exis�ng chimney then either a prefabricated block chimney in

accordance with Building Regula�ons Approved Document J or a twin walled insulated stainless steel flue

to BS 1856-1.

Insulated chimneys must be fi�ed in accordance with the manufacturer’s instruc�ons and Building Regula�ons.

A single wall metal flue pipe is suitable for connec�ng the stove to the chimney but is not suitable for using for the

complete chimney. The connec�ng flue pipe must have a minimum diameter of 125 mm and its dimension

should be not less than the size of the outlet socket of the stove. Registered smoke exempt models burning

wood only can be installed on a flue of 125mm throughout. Any bend in the chimney or connec�ng flue pipe

should not exceed 45. 90 degree bends should not be used other than within 150 mm of stove rear flue outlet.

A chimney height of not less than 4.5 metres measured ver�cally from the outlet of the stove to the top of

the chimney should be sa�sfactory. Alterna�vely the calcula�on procedure given in BS5854:1980 may be used

as the basis for deciding whether a par�cular chimney design will provide sufficient draught.

If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternately

a draught stabiliser should be fi�ed. The adjustable flue damper should not close off the flue en�rely but should

in its closed posi�on leave a minimum con�nuous opening free area of at least 20 % of the total cross sec�onal

area of the flue or flue pipe.

Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and

connec�ng flue pipe.

Your appliance needs to be maintained rou�nely, the throat plate/baffle should be cleaned regularly (monthly)

The flue pipe can be cleaned using a flexible brush. Only use a dry cloth on external surfaces. Over �me the

glass may become dirty, Clean with a damp cloth and polish off with damp cloth. If the stove has not been

used for some �me the flue should be checked for blockages before use. Do not modify the appliance; only

use spares authorised by the manufacturer.

FLUE & CHIMNEY CONNECTION TO STOVE

STOVE PERFORMANCE & TESTING

Mendip Stoves are approved and tested in accordance with EN 13240.

Содержание Loxton 3

Страница 1: ...1 of 24 OPERATION AND INSTALLATION MANUAL Mul fuel and SE models Loxton 3 MK3 October 2020 V2 ENG FR Guide d u lisa on et Mode d Emploi...

Страница 2: ...ict of informa on the wording on the website shall prevail Important Note Should any problems be experienced with your product claims must first be submi ed to the Retailer where the appliance was pur...

Страница 3: ...in BS EN 50292 2002 and from the alarm manufacturer s instruc ons Provision of an alarm must not be considered a subs tute for either installing the appliance correctly or ensuring regular servicing a...

Страница 4: ...red due to the difference in combus on between the stove and the open fire If there is no exis ng chimney then either a prefabricated block chimney in accordance with Building Regula ons Approved Docu...

Страница 5: ...ce of 100mm will give a be er heat output All non combus ble walls closer than 100mm to the stove should be at least 75mm thick For prac cal reasons the back wall of the fireplace recess and the heart...

Страница 6: ...should be warned to use a fireguard to BS 8423 2002 in the presence of children aged and or infirm persons The hearth should be able to accommodate the weight of the stove and its chimney if the chimn...

Страница 7: ...YOUR WOODBURNING STOVE To re fuel your stove in the cleanest way Only refuel your stove when flames have died down and you have glowing embers Before refuelling open secondary air slider fully Open do...

Страница 8: ...m the logs fully established close the secondary air supply to the low output se ng When opera ng at high output secondary air set fully open the new refuel charge does not require any boost air to es...

Страница 9: ...and air dried under cover for two years before being used as firewood Do not burn liquid fuels dri wood finished sawn wood pallet wood chipboard plywood varnished wood or plas c coated wood wood trea...

Страница 10: ...hot for over 24 hours Ash must be stored in a non combus ble container and must not be mixed with other combus ble waste Prolonged non use summer If the stove is to be le unused for a prolonged perio...

Страница 11: ...s are flammable and therefore dangerous to use around a lit stove Do not use aerosols sprays near a lit stove The use of any aerosol is dangerous and care must be taken in handling aerosols Warning No...

Страница 12: ...nded fuels listed above nor does it cover instruc ons for the use of other fuels 1 Fire Will Not Burn check a the air inlet is not obstructed in any way b that chimney and flue ways are clear c that a...

Страница 13: ...13 of 24 Loxton 3 Mk3 October 2020 onwards par r d octobre 2020 1 1 21 3 10 7 9 11 12 6 13 17 18 16 15 19 20 4 5 15 2 14 8 23 22 22 2...

Страница 14: ...sures AVERTISSEMENT IMPORTANT Ce po le ne doit pas tre install dans une chemin e servant d autres appareils de chauffage La pi ce o est plac le po le ne doit pas tre quip e d un disposi f d extrac on...

Страница 15: ...nner le poele de fa on sa sfaisante la hauteur de la chemin e doit tre suffisante pour assurerun rage ad quat pour effacer les produits de combus on et de pr venir les probl mes de fum e dans la pi ce...

Страница 16: ...n cessaire de pr voir avec le po le des entr es d air suffisantes pour un fonc onnement efficace pour assurer la s curit des habitants et parer toute ventualit Cela est par culi rement n cessaire si...

Страница 17: ...n cessaires l u lisateur en cas d mana ons de fum es par le po le Le client doit tre aver de l u lisa on d un pare feu la norme BS 8423 2002 en pr sence des enfants ou de personnes g s ou infirmes FON...

Страница 18: ...ige une pr sence intermi ente Ne le laissez pas marcher toute la nuit ou pendant de longues p riodes sans surveillance Le po le deviendra tr s chaud faites a en on U lisez le gant et les accessoires f...

Страница 19: ...mani re la plus propre ne placez pas de combus ble dans votre po le lorsque les flammes se sont apais es ou que vous avez des braises Avant de faire le plein ouvrez l air pleinement et placer le levie...

Страница 20: ...pl tement ouvert jusqu ce que le nouveau bois a pris et est en train de br ler puis fermer le tirette d air secondaire sa position op rationnelle De retour au po le dans la matin e le feu aura teinte...

Страница 21: ...Non u lisa on prolong e d t Si le po le n est pas u lis pendant une p riode de temps prolong e par exemple pendant l t alors un ne oyage en profondeur pour liminer les r sidus de cendres et de carbura...

Страница 22: ...moner la chemin e travers l appareil Si une chemin e a t u lis e pour une installa on de feu ouvert il est possible que la temp rature des gaz de combus on plus lev e par r d un appareil ferm puisse d...

Страница 23: ...23 of 24...

Страница 24: ...s Ltd 2019 MK3 ver 2 April 2021 Mendip Stoves Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Tel 01934 750 500 www mendipstoves co uk E mail info mendipstoves co uk COD...

Отзывы: