5.  CONNECTING CONVERTER CABLES

The converter and power source must be in the OFF mode.

IMPORTANT:

 Make sure you connect your converter to a 12-volt power 

supply only.

CONVERTER CONNECTION

1. 

Locate the positive and negative plastic terminals located on the right 

side of the converter and remove the terminal caps completely.

2. 

Install the positive (red) cable ring lug onto the positive (red) termi-

nal screw. Install the negative (black) cable ring lug onto the negative 

(black) terminal screw. Tighten each terminal so that the cable cannot 

come loose.

CONNECTING CONVERTER CABLE TO A VEHICLE  

(100 WATTS MAXIMUM):

1. 

Remove the cigarette lighter from its outlet.

2. 

Push the 12-volt power plug firmly into the outlet.

CONNECTING CONVERTER CABLES TO 12V BATTERY  

OR 12V POWER SOURCE:

1. 

Keep hands, hair, clothing and jewelry clear of battery terminals.

2. 

Wear eye protection and clothing protection.

3. 

Connect the positive (red) converter terminal cable to the power source 

positive (+) or battery terminal. Make sure the connection is secure.

4. 

Connect the negative (black) converter terminal cable to the power 

source negative (-) or battery terminal. Make sure the connection is 

secure.

5. 

To disconnect the converter, reverse the above steps.

NOTE:

 The internal speaker may make a brief “beep” when the converter 

is being connected to or disconnected from the 12-volt power source.

IMPORTANT:

 Failure to make the correct connections will result in blown 

fuses and permanent damage to the converter.

Содержание MASTERFORCE 260-9519

Страница 1: ...To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference 260 9519 0099002188 00 410W Power Converter...

Страница 2: ...efore Using Your Converter Page 6 Fastening The Converter To A Flat Surface Page 8 Connecting Converter Cables Page 9 Operating Instructions Page 10 Power Source Page 11 How Power Converters Work Page...

Страница 3: ...of current Direct current Type or characteristic of current Class II construction Double insulated construction Read the operator s manual To reduce the risk of injury read and understand the operator...

Страница 4: ...lt in electric shock fire and or serious personal injury SYMBOL MEANING SAFETY ALERT SYMBOL Indicates DANGER WARNING or CAUTION May be used in conjunction with other symbols or pictographs Failure to...

Страница 5: ...not disassemble the converter take it to a qualified service per son when service or repair is required Incorrect reassembly may result in a risk of fire or electric shock 1 11 Make sure the converter...

Страница 6: ...ce or system or to affect the safety or effectiveness of that device or system 2 2 Wear complete eye and clothing protection when working near lead acid batteries Always have someone nearby for help 2...

Страница 7: ...calculate the continuous load Continuous Load AMPS x 120 AC Voltage IMPORTANT Always run a test to establish whether the converter will operate a particular piece of equipment or device In the event o...

Страница 8: ...he battery charger for about 10 minutes If the battery charger becomes abnormally warm disconnect it from the converter immediately NOTE You can use an extension cord from the converter to the device...

Страница 9: ...ighter from its outlet 2 Push the 12 volt power plug firmly into the outlet CONNECTING CONVERTER CABLES TO 12V BATTERY OR 12V POWER SOURCE 1 Keep hands hair clothing and jewelry clear of battery termi...

Страница 10: ...your television picture especially with weak signals Below are some suggestions to try and improve reception 1 Try altering the position of the converter antenna cables and television power cord Add a...

Страница 11: ...is off we recommend you turn OFF the device plugged into the converter before starting the engine To maintain battery power start the engine every 2 to 3 hours and let it run for approximately 10 minu...

Страница 12: ...continuous load demand from the equipment or device being operated exceeds the continuous load rating of the converter being used The Green LED is on the Red LED pulses Use a higher capac ity converte...

Страница 13: ...of the converter IMPORTANT Do not install a fuse with a higher amp rating than the original fuse as this may damage the converter and any product you use with the converter Make sure to correct the c...

Страница 14: ...raw 0 6A Input voltage range 10 0V 15 0V DC Output voltage range 110V 125V AC Low battery alarm Audible 10 5V 0 5V DC Optimum efficiency 85 13 REPLACEMENT PARTS Replacement fuses can be purchased at m...

Страница 15: ...This warranty 1 excludes expendable parts including but not limited to blades brushes belts bits light bulbs and or batteries 2 shall be void if this product is used for commercial and or rental purp...

Страница 16: ...2020 Menard Inc Eau Claire WI 54703 03 2020...

Отзывы: