USING THE USB PORT

The USB port provides up to 2A at 5V DC.

1. 

Plug the device into the USB port.

2. 

Turn the USB device on.

3. 

Reverse these steps when finished using the USB port.

4. 

Reverse these steps when finished using the USB port.

  The converter draws power, even when the switch is OFF.  

To avoid battery drain, disconnect the converter when not in use.

7.  POWER SOURCE

Your average automobile or marine battery at full charge will provide an 

ample power supply to the converter for approximately 3 hours when the 

engine is off. The actual length of time the converter will function depends 

on the age and condition of the battery and the power demand being placed 

by the device being operated with the converter.
If you decide to use the converter while the engine is off, we recommend 

you turn OFF the device plugged into the converter before starting the 

engine. To maintain battery power, start the engine every 2 to 3 hours and 

let it run for approximately 10 minutes to recharge the battery.
Although it is not necessary to disconnect the converter when turning over 

the engine, it may briefly cease to operate as the battery voltage decreases. 

While the converter draws very low amperage when not in use, it should be 

unplugged to avoid battery drain.

8.  HOW POWER CONVERTERS WORK

There are two stages involved in converting 12 volt DC (battery) power into 

120 volt AC (household voltage):

STAGE 1:

 The power converter uses a DC to DC transformer to increase the 

12-volt DC input voltage from the power source to 145 volt DC.

STAGE 2:

 The converter then converts the 145 volt DC into 120 volts AC 

(household voltage) using advanced MOSFET transistors in a full bridge 

configuration. A “modified sine wave” waveform is generated by this 

conversion.

Содержание MASTERFORCE 260-9519

Страница 1: ...To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference 260 9519 0099002188 00 410W Power Converter...

Страница 2: ...efore Using Your Converter Page 6 Fastening The Converter To A Flat Surface Page 8 Connecting Converter Cables Page 9 Operating Instructions Page 10 Power Source Page 11 How Power Converters Work Page...

Страница 3: ...of current Direct current Type or characteristic of current Class II construction Double insulated construction Read the operator s manual To reduce the risk of injury read and understand the operator...

Страница 4: ...lt in electric shock fire and or serious personal injury SYMBOL MEANING SAFETY ALERT SYMBOL Indicates DANGER WARNING or CAUTION May be used in conjunction with other symbols or pictographs Failure to...

Страница 5: ...not disassemble the converter take it to a qualified service per son when service or repair is required Incorrect reassembly may result in a risk of fire or electric shock 1 11 Make sure the converter...

Страница 6: ...ce or system or to affect the safety or effectiveness of that device or system 2 2 Wear complete eye and clothing protection when working near lead acid batteries Always have someone nearby for help 2...

Страница 7: ...calculate the continuous load Continuous Load AMPS x 120 AC Voltage IMPORTANT Always run a test to establish whether the converter will operate a particular piece of equipment or device In the event o...

Страница 8: ...he battery charger for about 10 minutes If the battery charger becomes abnormally warm disconnect it from the converter immediately NOTE You can use an extension cord from the converter to the device...

Страница 9: ...ighter from its outlet 2 Push the 12 volt power plug firmly into the outlet CONNECTING CONVERTER CABLES TO 12V BATTERY OR 12V POWER SOURCE 1 Keep hands hair clothing and jewelry clear of battery termi...

Страница 10: ...your television picture especially with weak signals Below are some suggestions to try and improve reception 1 Try altering the position of the converter antenna cables and television power cord Add a...

Страница 11: ...is off we recommend you turn OFF the device plugged into the converter before starting the engine To maintain battery power start the engine every 2 to 3 hours and let it run for approximately 10 minu...

Страница 12: ...continuous load demand from the equipment or device being operated exceeds the continuous load rating of the converter being used The Green LED is on the Red LED pulses Use a higher capac ity converte...

Страница 13: ...of the converter IMPORTANT Do not install a fuse with a higher amp rating than the original fuse as this may damage the converter and any product you use with the converter Make sure to correct the c...

Страница 14: ...raw 0 6A Input voltage range 10 0V 15 0V DC Output voltage range 110V 125V AC Low battery alarm Audible 10 5V 0 5V DC Optimum efficiency 85 13 REPLACEMENT PARTS Replacement fuses can be purchased at m...

Страница 15: ...This warranty 1 excludes expendable parts including but not limited to blades brushes belts bits light bulbs and or batteries 2 shall be void if this product is used for commercial and or rental purp...

Страница 16: ...2020 Menard Inc Eau Claire WI 54703 03 2020...

Отзывы: