When you turn on a device or a tool that runs on a motor, the device basically 

goes through two stages:

1.  Start Up –

 Requiring an initial surge of power (commonly known as the 

“starting” or “peak” load).

2.  Continuous Operation –

 Power consumption drops (commonly known 

as the “continuous load”).

The wattage (WATTS) or amperes (AMPS) can normally be found stamped or 

printed on most devices and equipment, or in the user’s manual. Otherwise, 

contact the manufacturer to find out whether the device you want to use is 

compatible with a modified sine wave.

To calculate the wattage:

  

Wattage = AMPS x 120 (AC Voltage).

To calculate the starting load:

  

Starting Load = 2 x WATTS. 

In general, the startup load of the device or power tool determines whether 

your converter has the capability to power it.

To calculate the continuous load:

  

Continuous Load = AMPS x 120 (AC Voltage).

IMPORTANT: 

Always run a test to establish whether the converter will 

operate a particular piece of equipment or device. In the event of a power 

overload, the converter is designed to automatically shut down. This 

safety feature prevents damaging the converter while testing devices and 

equipment within the wattage range of the converter.

IMPORTANT: 

When using the vehicle’s 12 volt accessory port, this converter 

is designed to supply 60 to 70 watts when the vehicle is not running. With 

the vehicle’s engine running, it can supply up to 100 watts. To use the full 

output, you must connect the converter directly to your battery.

NOTE: 

The 100 watt limit is to accommodate the fuse ratings for all vehicles. 

Some vehicles may allow the full output. If the fuse blows when you switch 

on the device you are trying to use, you have to either use a smaller device 

or you must connect the converter directly to the battery.

Содержание MASTERFORCE 260-9519

Страница 1: ...To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference 260 9519 0099002188 00 410W Power Converter...

Страница 2: ...efore Using Your Converter Page 6 Fastening The Converter To A Flat Surface Page 8 Connecting Converter Cables Page 9 Operating Instructions Page 10 Power Source Page 11 How Power Converters Work Page...

Страница 3: ...of current Direct current Type or characteristic of current Class II construction Double insulated construction Read the operator s manual To reduce the risk of injury read and understand the operator...

Страница 4: ...lt in electric shock fire and or serious personal injury SYMBOL MEANING SAFETY ALERT SYMBOL Indicates DANGER WARNING or CAUTION May be used in conjunction with other symbols or pictographs Failure to...

Страница 5: ...not disassemble the converter take it to a qualified service per son when service or repair is required Incorrect reassembly may result in a risk of fire or electric shock 1 11 Make sure the converter...

Страница 6: ...ce or system or to affect the safety or effectiveness of that device or system 2 2 Wear complete eye and clothing protection when working near lead acid batteries Always have someone nearby for help 2...

Страница 7: ...calculate the continuous load Continuous Load AMPS x 120 AC Voltage IMPORTANT Always run a test to establish whether the converter will operate a particular piece of equipment or device In the event o...

Страница 8: ...he battery charger for about 10 minutes If the battery charger becomes abnormally warm disconnect it from the converter immediately NOTE You can use an extension cord from the converter to the device...

Страница 9: ...ighter from its outlet 2 Push the 12 volt power plug firmly into the outlet CONNECTING CONVERTER CABLES TO 12V BATTERY OR 12V POWER SOURCE 1 Keep hands hair clothing and jewelry clear of battery termi...

Страница 10: ...your television picture especially with weak signals Below are some suggestions to try and improve reception 1 Try altering the position of the converter antenna cables and television power cord Add a...

Страница 11: ...is off we recommend you turn OFF the device plugged into the converter before starting the engine To maintain battery power start the engine every 2 to 3 hours and let it run for approximately 10 minu...

Страница 12: ...continuous load demand from the equipment or device being operated exceeds the continuous load rating of the converter being used The Green LED is on the Red LED pulses Use a higher capac ity converte...

Страница 13: ...of the converter IMPORTANT Do not install a fuse with a higher amp rating than the original fuse as this may damage the converter and any product you use with the converter Make sure to correct the c...

Страница 14: ...raw 0 6A Input voltage range 10 0V 15 0V DC Output voltage range 110V 125V AC Low battery alarm Audible 10 5V 0 5V DC Optimum efficiency 85 13 REPLACEMENT PARTS Replacement fuses can be purchased at m...