![MEN BL70S Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/men/bl70s/bl70s_user-manual_1770475076.webp)
Hardware/Software Interface
Page 76
Command ERRCNT_xx (16 to 32)
Command ERR_CNT_CLR
This command clears all error counters.
Command NUM_ERR_CNTRS
Opcode:
0xB0
+ x
Packet Type:
PT_RBD
Bit
7
6
5
4
3
2
1
0
Data
Value of error counter number xx
Opcode:
0x7F
Packet Type:
PT_WBD
Bit
7
6
5
4
3
2
1
0
Data
0x69
Opcode:
0x8D
Packet Type:
PT_RBD
Bit
7
6
5
4
3
2
1
0
Data
Number of error counters